Core-peripheral Temperature Gradient and Skin temperature as Predictors of Major Adverse Events among Postoperative Pediatric Cardiac Patients

Author(s):  
Satoshi Kimura ◽  
Warwick Butt
Phlebologie ◽  
2008 ◽  
Vol 37 (01) ◽  
pp. 3-6 ◽  
Author(s):  
F. G. Bruins ◽  
H. A. M. Neumann ◽  
K.-P. de Roos

Summary Aim: The study was designed to evaluate the feasibility, results and safety of a very short period of compression after ambulatory phlebectomy. Patients, methods: From September to December 2006 we prospectively studied 49 subsequent patients who underwent ambulatory phlebectomy for branch varicose veins. Post-operatively the treated part of the leg was bandaged for forty-eight hours. Results: No major adverse events occurred. Although 46.9% of treated patients had visible haematomas two days post-operatively, after six weeks this was only visible in one patient. The results of this study show that the clinical outcome of ambulatory phlebectomy in combination with compression for forty-eight hours is at least equal to a conventional (longer) period of compression. Conclusion: Post-operative treatment can be safely reduced without the need of adjuvant compression hosiery. This will reduce patient discomfort after ambulatory phlebectomy without jeopardizing the clinical outcome.


2019 ◽  
Vol 2 (1) ◽  
Author(s):  
Jesse Manunga ◽  
Larissa I. Stanberry ◽  
Peter Alden ◽  
Jason Alexander ◽  
Nedaa Skeik ◽  
...  

Abstract Background Endovascular rescue of failed infrarenal repair (EVAR) has emerged as an attractive option to stent graft explantation. The procedure, however, is underutilized due to limited devices accessibility and the challenges associated with their implantation in this patient population. The purpose of this study was to report our outcomes and discuss our approach to rescuing previously failed infrarenal endovascular aneurysm repairs (EVAR) with fenestrated/branched endografts (f/b-EVAR). Methods A retrospective analysis of prospectively collected data of consecutive patients with failed EVAR rescued with f/b-EVAR at our institution from November 2013 to March 2019 was conducted. The study primary end point was technical success; defined as the implantation of the device with no type I a/b or type III endoleak or conversion to open repair. Secondary endpoints included major adverse events (MAEs), graft patency and reintervention rates. Results During this time, 202 patients with complex aortic aneurysms were treated with f/b-EVAR. Of these, 19 patients (Male: 17, mean age 79 ± 7 years) underwent repair for failed EVAR. The median time from failed repair to f/b-EVAR was 48 (30, 60) months. Treatment failure was attributed to stent graft migration in 9 (47.4%) patients, disease progression in 5 (26.3%), short initial neck in 3 (15.8%) and unable to be determined in 2 (10.5%). Three patients were treated urgently with surgeon modified stent graft. Technical success was achieved in 18 patients (95%), including two who had undergone emergent repair for rupture. Seventy-two targeted vessels (97.3%) were successfully incorporated. Sixteen (84.2%) patients required a thoracoabdominal repair to achieve a durable seal. Major adverse events (MAEs) occurred in 3 patients (15.7%) including paralysis and death in one (5.3%), compartment syndrome and temporary dialysis in another and laparotomy with snorkeling of one renal and bypass of the other in the third patient. Median (IQR) hospital length of stay was 3 (2, 4) days. Late reintervention, primary target vessel patency and primary assisted patency rates were 5.3%, 98.6% and 100%, respectively. Conclusion Implantation of f/b-EVAR in patients with failed previous EVAR is a challenging undertaking that can be performed safely with a high technical success and low reintervention rates.


2015 ◽  
Vol 210 (5) ◽  
pp. 896-903 ◽  
Author(s):  
Ramy Behman ◽  
Sherif Hanna ◽  
Natalie Coburn ◽  
Calvin Law ◽  
David P. Cyr ◽  
...  

2012 ◽  
Vol 29 (9) ◽  
pp. 1273-1283 ◽  
Author(s):  
Kurt Kräuchi ◽  
Britta Gompper ◽  
Daniela Hauenstein ◽  
Josef Flammer ◽  
Marlon Pflüger ◽  
...  

Perfusion ◽  
2021 ◽  
pp. 026765912110638
Author(s):  
Hüsnü Kamil Limandal ◽  
Mehmet Ali Kayğın ◽  
Servet Ergün ◽  
Taha Özkara ◽  
Mevriye Serpil Diler ◽  
...  

Purpose The primary aim of this study was to examine the effects of two oxygenator systems on major adverse events and mortality. Methods A total of 181 consecutive patients undergoing coronary artery bypass grafting in our clinic were retrospectively analyzed. The patients were divided into two groups according to the oxygenator used: Group M, in which a Medtronic Affinity (Medtronic Operational Headquarters, Minneapolis, MN, USA) oxygenator was used, and Group S, in which a Sorin Inspire (Sorin Group Italia, Mirandola, Italy) oxygenator was used. Results Group S consisted of 89 patients, whereas Group M included 92 patients. No statistically significant differences were found between the two groups in terms of age ( p = .112), weight ( p = .465), body surface area ( p = .956), or gender ( p = .484). There was no statistically significant difference in hemorrhage on the first or second postoperative day ( p = .318 and p = .455, respectively). No statistically significant differences were observed in terms of red blood cell ( p = .468), fresh frozen plasma ( p = .116), or platelet concentrate transfusion ( p = .212). Infections, wound complications, and delayed sternal closure were significantly more common in Group M ( p = .006, p = .023, and p = .019, respectively). Extracorporeal membrane oxygenators and intra-aortic balloon pumps were required significantly more frequently in Group S ( p = .025 and p = .013, respectively). Major adverse events occurred in 16 (18%) patients in Group S and 14 (15.2%) patients in Group M ( p = .382). Mortality was observed in six (6.7%) patients in Group S and three (3.3%) patients in Group M ( p = .232). No statistically significant difference was found between the two groups in terms of length of hospital stay ( p = .451). Conclusion The clinical outcomes of the two oxygenator systems, including mortality, major adverse events, hemorrhage, erythrocyte and platelet transfusions, and length of hospital stay, were similar.


2021 ◽  
Vol 108 (Supplement_7) ◽  
Author(s):  
Shahab Hajibandeh ◽  
Shahin Hajibandeh

Abstract Aims to evaluate prognostic significance of metabolic syndrome (MetS) in patients undergoing carotid artery revascularisation. Methods A systematic review and meta-analysis was performed in compliance with PRISMA standards to evaluate prognostic significance of MetS in patients undergoing carotid endarterectomy or carotid stenting. Short-term (<30 days) postoperative outcomes (all-cause mortality, stroke or transient ischaemic attack (TIA), myocardial infarction, major adverse events) and long-term outcomes (restenosis, all-cause mortality, stroke or TIA, myocardial infarction, major adverse events) were considered as outcomes of interest. Random effects modelling was applied for the analyses. Results Analysis of 3721 patients from five cohort studies showed no difference between the MetS and no MetS groups in terms of the following short-term outcomes: all-cause mortality (OR: 1.67,P=0.32), stroke or TIA (OR: 2.44,P=0.06), myocardial infarction (OR: 1.01,P=0.96), major adverse events (OR: 1.23, P = 0.66). In terms of long-term outcomes, MetS was associated with higher risk of restenosis (OR: 1.75,P=0.02), myocardial infarction (OR: 2.12,P=0.04), and major adverse events (OR: 1.30, P = 0.009) but there was no difference between the two groups in terms of all-cause mortality (OR: 1.11, P = 0.25), and stroke or TIA (OR: 1.24, P = 0.33). The quality and certainty of the available evidence were judged to be moderate. Conclusions The best available evidence suggest that although MetS may not affect the short-term postoperative morbidity and mortality outcomes in patients undergoing carotid revascularisation, it may result in higher risks of restenosis, myocardial infarction and major adverse events in the long-term. Evidence from large prospective cohort studies are required for more robust conclusions.


Sign in / Sign up

Export Citation Format

Share Document