scholarly journals Bonding All-Ceramic Restorations with Two Resins Cement Techniques: A Clinical Report of Three-Year Follow-Up

2011 ◽  
Vol 05 (04) ◽  
pp. 478-485 ◽  
Author(s):  
Rodolfo Bruniera Anchieta ◽  
Eduardo Passos Rocha ◽  
Erika Oliveira de Almeida ◽  
Amilcar Chagas Freitas Junior ◽  
Ana Paula Martini

ABSTRACTCeramics have been widely used for esthetic and functional improvements. The resin cement is the material of choice for bonding ceramics to dental substrate and it can also dictate the final esthetic appearance and strength of the restoration. The correct use of the wide spectrum of resin luting agents available depends on the dental tooth substrate. This article presents three-year clinical results of a 41 years old female patient B.H.C complaining about her unattractive smile. Two all-ceramic crowns and two laminates veneers were placed in the maxillary incisors and cemented with a self-adhesive resin luting cement and conventional resin luting cement, respectively. After a three-year follow-up, the restorations and cement/teeth interface were clinically perfect with no chipping, fractures or discoloration. Proper use of different resin luting cements shows clinical appropriate behavior after a three-year follow-up. Self-adhesive resin luting cement may be used for cementing all-ceramic crowns with high predictability of success, mainly if there is a large dentin surface available for bonding and no enamel at the finish line. Otherwise, conventional resin luting agent should be used for achieving an adequate bonding strength to enamel. (Eur J Dent 2011;5:478-485)

2008 ◽  
Vol 33 (4) ◽  
pp. 392-399 ◽  
Author(s):  
C. P. Trajtenberg ◽  
S. J. Caram ◽  
S. Kiat-amnuay

Clinical Relevance Among the self-adhesive resin cements, Panavia F 2.0 demonstrated less microleakage than RelyX Unicem or Multilink, whether or not a die spacer technique was used.


Materials ◽  
2020 ◽  
Vol 13 (5) ◽  
pp. 1094 ◽  
Author(s):  
Chin-Yun Pan ◽  
Ting-Hsun Lan ◽  
Pao-Hsin Liu ◽  
Wan-Ru Fu

This study aimed to conduct a stress analysis of four types of cervical finish lines in posterior all-ceramic crowns on the primary roots of molar teeth. Four different types of finish lines (shoulder 0.5 mm, feather-edged, chamfer 0.6 mm, and mini chamfer 0.4 mm) and two all-ceramic crown materials (zirconia and lithium disilicate) were used to construct eight finite element primary tooth models with full-coverage crowns. A load of 200 N was applied at two different loading angles (0° and 15°) so as to mimic children’s masticatory force and occlusal tendency. The maximum stress distribution from the three-dimensional finite element models was determined, and the main effect of each factor (loading type, material, and finish line types) was evaluated in terms of the stress values for all of the models. The results indicated that the loading type (90.25%) was the main factor influencing the maximum stress value of the primary root, and that the feather-edged margin showed the highest stress value (p = 0.002). In conclusion, shoulder and chamfer types of finish lines with a 0.4–0.6 mm thickness are recommended for deciduous tooth preparation, according to the biomechanical analysis.


2016 ◽  
Vol 41 (6) ◽  
pp. 666-671 ◽  
Author(s):  
C Gillette ◽  
R Buck ◽  
N DuVall ◽  
S Cushen ◽  
M Wajdowicz ◽  
...  

SUMMARY Objective: To evaluate the significance of reduced axial wall height on retention of adhesively luted, all-ceramic, lithium disilicate premolar computer-aided design/computer-aided manufacturing (CAD/CAM) crowns based on preparations with a near ideal total occlusal convergence of 10°. Methods: Forty-eight recently extracted premolars were randomly divided into four groups (n=12). Each group received all-ceramic CAD/CAM crown preparations featuring axial wall heights of 0, 1, 2, and 3 mm, respectively, all with a 10° total occlusal convergence. Scanned preparations were fitted with lithium disilicate all-ceramic crowns that were luted with a self-etching resin cement. Specimens were tested to failure at a 45° angle to the tooth long axis with failure load converted to megapascals (MPa) based on the measured bonding surface area. Mean data were analyzed using analysis of variance/Tukey's post hoc test (α=0.05). Results: Lithium disilicate crowns adhesively luted on preparations with 0 axial wall height demonstrated significantly less failure resistance compared with the crowns luted on preparations with axial wall heights of 1 to 3 mm. There was no failure stress difference between preparations with 1 to 3 mm axial wall height. Conclusions: Under conditions of this study, adhesively luted lithium disilicate bicuspid crowns with a total occlusal convergence of 10° demonstrated similar failure resistance independent of axial wall height of 1 to 3 mm. This study provides some evidence that adhesion combined with an ideal total occlusal convergence may compensate for reduced axial wall height.


2018 ◽  
Vol 6 (3) ◽  
pp. 548-553 ◽  
Author(s):  
Bandar M. A. Al–Makramani ◽  
Abdul A. A. Razak ◽  
Mohamed I. Abu–Hassan ◽  
Fuad A. Al–Sanabani ◽  
Fahad M. Albakri

BACKGROUND: The selection of the appropriate luting cement is a key factor for achieving a strong bond between prepared teeth and dental restorations.AIM: To evaluate the shear bond strength of Zinc phosphate cement Elite, glass ionomer cement Fuji I, resin-modified glass ionomer cement Fuji Plus and resin luting cement Panavia-F to Turkom-Cera all-ceramic material.MATERIALS AND METHODS: Turkom-Cera was used to form discs 10mm in diameter and 3 mm in thickness (n = 40). The ceramic discs were wet ground, air - particle abraded with 50 - μm aluminium oxide particles and randomly divided into four groups (n = 10). The luting cement was bonded to Turkom-Cera discs as per manufacturer instructions. The shear bond strengths were determined using the universal testing machine at a crosshead speed of 0.5 mm/min. The data were analysed using the tests One Way ANOVA, the nonparametric Kruskal - Wallis test and Mann - Whitney Post hoc test.RESULTS: The shear bond strength of the Elite, Fuji I, Fuji Plus and Panavia F groups were: 0.92 ± 0.42, 2.04 ± 0.78, 4.37 ± 1.18, and 16.42 ± 3.38 MPa, respectively. There was the statistically significant difference between the four luting cement tested (p < 0.05).CONCLUSION: the phosphate-containing resin cement Panavia-F exhibited shear bond strength value significantly higher than all materials tested.


2002 ◽  
Vol 11 (4) ◽  
pp. 336-336
Author(s):  
Seung‐Heuk Chang ◽  
Hans‐Peter Weber

2010 ◽  
Vol 34 (4) ◽  
pp. 309-312 ◽  
Author(s):  
Priya Subramaniam ◽  
Sapna Kondae ◽  
Kamal Kishore Gupta

The present study evaluated and compared the retentive strength of three luting cements. A total of forty five freshly extracted human primary molars were used in this study. The teeth were prepared to receive stainless steel crowns. They were then randomly divided into three groups, of fifteen teeth each, so as to receive the three different luting cements: conventional glass ionomer, resin modified glass ionomer and adhesive resin. The teeth were then stored in artificial saliva for twenty four hours. The retentive strength of the crowns was determined by using a specially designed Instron Universal Testing Machine (Model 1011). The data was statistically analyzed using ANOVA to evaluate retentive strength for each cement and Tukey test for pair wise comparison. It was concluded that retentive strength of adhesive resin cement and resin modified glass ionomer cement was significantly higher than that of the conventional glass ionomer cement.


2021 ◽  
Vol 2021 ◽  
pp. 1-7
Author(s):  
Behnaz Ebadian ◽  
Amirhossein Fathi ◽  
Melika Savoj

Introduction. Discrepancy between the crown border and prepared tooth margin leads to a microleakage that eases the penetration of microorganisms and causes the dissolution of luting cement consequently. Several factors should be considered to achieve optimal fitness, including tooth preparation taper and type of cementing agent. The study aimed to determine the relation of tooth preparation taper and cement type on the microleakage of zirconia crowns. Materials and Methods. Fifty-six freshly extracted premolars without caries and restorations were selected as the study sample and divided into two groups of different tapering degrees (6 and 12 degrees). Zirconia copings were designed and fabricated by the CAD/CAM system. The samples were divided into four subgroups for cementation, and each subgroup was cemented with a different luting cement (n = 7). After 5000 thermocycles at 5°C–55°C and dye penetration, the specimens were sectioned in the mid-buccolingual direction, and a digital photograph of each section was taken under a stereomicroscope. Data were analyzed by the Kruskal–Wallis and Mann–Whitney tests (α = 0.05). Results. The results showed significant differences among the four types of luting cement in marginal permeability (PV < 0.001). Regardless of the type of cement, the 12-degree tapering resulted in a lower microleakage (46.4% without microleakage) with statistically significant differences from the 6-degree tapering (PV = 0.042). Conclusion. Within the limitations of this study, increasing the tapering degree of the prepared tooth for CAD/CAM zirconia copings improved the marginal fit and decreased the microleakage score. In addition, total-etch resin cement indicated the least microleakage.


2016 ◽  
Vol 17 (12) ◽  
pp. 1016-1021 ◽  
Author(s):  
Mathew Thomas ◽  
Mohammed Mustafa ◽  
Reshma Karkera ◽  
AP Nirmal Raj ◽  
Lijo Isaac ◽  
...  

ABSTRACT Introduction This study was planned to find the solubility of the conventional luting cements in comparison with that of the polyacid-modified composite luting cement and recently introduced resin-modified glass ionomer cement (RMGIC) with exposure to water at early stages of mixing. Materials and methods An in vitro study of the solubility of the following five commercially available luting cements, viz., glass ionomer cement (GIC) (Fuji I, GC), zinc phosphate (Elite 100, GC), polyacid-modified resin cement (PMCR) (Principle, Dentsply), polycarboxylate cement (PC) (Poly - F, Dentsply), RMGIC (Vitremer, 3M), was conducted. For each of these groups of cements, three resin holders were prepared containing two circular cavities of 5 mm diameter and 2 mm depth. All the cements to be studied were mixed in 30 seconds and then placed in the prepared cavities in the resin cement holder for 30 seconds. Results From all of the observed luting cements, PMCR cement had shown the lowest mean loss of substance at all immersion times and RMGIC showed the highest mean loss of substance at all immersion times in water from 2 to 8 minutes. The solubility of cements decreased by 38% for GIC, 33% for ZnPO4, 50% for PMCR, 29% for PC, and 17% for RMGIC. Conclusion The PMCR cement (Principle-Dentsply) had shown lowest solubility to water at the given time intervals of immersion. This was followed by PC, zinc phosphate, and GIC to various time intervals of immersion. How to cite this article Karkera R, Nirmal Raj AP, Isaac L, Mustafa M, Reddy RN, Thomas M. Comparison of the Solubility of Conventional Luting Cements with that of the Polyacid Modified Composite Luting Cement and Resin-modified Glass Ionomer Cement. J Contemp Dent Pract 2016;17(12):1016-1021.


Sign in / Sign up

Export Citation Format

Share Document