Microleakage of All-ceramic Crowns Using Self-etching Resin Luting Agents

2008 ◽  
Vol 33 (4) ◽  
pp. 392-399 ◽  
Author(s):  
C. P. Trajtenberg ◽  
S. J. Caram ◽  
S. Kiat-amnuay

Clinical Relevance Among the self-adhesive resin cements, Panavia F 2.0 demonstrated less microleakage than RelyX Unicem or Multilink, whether or not a die spacer technique was used.

2008 ◽  
Vol 33 (5) ◽  
pp. 516-525 ◽  
Author(s):  
F. Schenke ◽  
K-A. Hiller ◽  
G. Schmalz ◽  
M. Federlin

Clinical Relevance Resin coating improves the marginal seal of partial ceramic crowns to dentin compared to conventional luting, especially at the dentin/composite interface. However, the self-adhesive material RelyX Unicem shows significantly better marginal integrity than the other materials tested.


2012 ◽  
Vol 37 (4) ◽  
pp. 417-424 ◽  
Author(s):  
E Cal ◽  
EU Celik ◽  
M Turkun

SUMMARY Objective To assess the microleakage of three self-adhesive and one etch-and-rinse resin cements when luting IPS Empress 2 (Ivoclar Vivadent, Liechtenstein) all-ceramic inlay restorations to the prepared cavities in extracted human molars. Methods The cylindrical Class V cavities were prepared on the buccal surfaces of 40 extracted human third molars using diamond burs. The IPS Empress 2 ceramic inlays were placed with Multilink Sprint (Ivoclar Vivadent), RelyX Unicem (3M ESPE, USA), G-Cem (GC, Japan), or Variolink II (Ivoclar Vivadent) as the control group. After storage in distilled water at 37°C for 24 hours, samples were subjected to 1000 thermal cycles between baths of 5°C and 55°C, with a dwell time of 30 seconds. The microleakage scores were examined on the occlusal and gingival margins at 30× magnification after each sample was stained with 0.5% basic fuchsin and sectioned into three parts using a thin diamond blade (Isomet, Buehler, USA) (n=40). The extent of microleakage on both occlusal and gingival margins of the restorations was scored and recorded. The microleakage data were analyzed using Kruskall-Wallis and Mann-Whitney U-tests. Results Statistically significant differences were observed between the groups in both margins according to the Kruskall-Wallis and Mann-Whitney U-tests (p<0.05). Microleakage scores on the occlusal margins were Variolink II < RelyX Unicem < G-Cem = Multilink Sprint. Microleakage scores on the gingival margins are Variolink II = RelyX Unicem < G-Cem < Multilink Sprint. Conclusion Self-adhesive resin cements displayed higher microleakage scores on the occlusal margins, whereas on the gingival margins RelyX Unicem showed comparable microleakage results with the control samples.


2012 ◽  
Vol 37 (5) ◽  
pp. 548-556 ◽  
Author(s):  
E Baena ◽  
MV Fuentes ◽  
MA Garrido ◽  
J Rodríguez ◽  
L Ceballos

SUMMARY Purpose To compare the microhardness of several dual-cure, self-adhesive resin cements used to lute fiber posts at 24 hours and seven days after cementation. Methods Bovine incisors were selected to lute 15 fiber posts that were 12 mm long (FRC Postec Plus size 3, Ivoclar-Vivadent). Five resin cements were tested: Multilink Automix (Ivoclar-Vivadent), without light-curing, and the self-adhesive resin cements Maxcem Elite (Kerr), RelyX Unicem (3M ESPE), G-Cem (GC), and Smartcem 2 (Dentsply), which were light-cured for 40 seconds (LED Bluephase, Ivoclar-Vivadent). Each root was embedded in chemically cured acrylic resin and stored at 37°C for 24 hours. The roots were transversally sectioned into nine specimens that were each 1 mm thick, with three specimens corresponding to each root third. Indentations (100g, 30 seconds) were performed on each section in the resin cement, at 24 hours and seven days after cementation, using a Vickers digital microdurometer (Buehler). Data were analyzed by two-way analysis of variance, Student-Newman-Keuls test, and paired t-test (p<0.05). Results A significant influence was found (p<0.05) for the resin cement evaluated, the root third, and their interactions on microhardness values at 24 hours and seven days after post cementation. RelyX Unicem and G-Cem exhibited the highest microhardness values, whereas Multilink Automix presented the lowest. All resin cements suffered a decrease in microhardness according to root canal depth, with the exception of G-Cem and Multilink Automix at 24 hours and Smartcem 2 after seven days. After seven days, the evaluated resin cements showed a significant increase in microhardness values, with the exception of Maxcem Elite and Smartcem 2 at the coronal third. Conclusions Microhardness of the self-adhesive resin cements when used to lute fiber posts was material-dependent and higher values were obtained in the coronal third, revealing their sensitivity to light irradiation. More information regarding the polymerization reaction of these cements is warranted. According to the current results, microhardness values were significantly higher one week after post luting.


2018 ◽  
Vol 34 (8) ◽  
pp. 1102-1111 ◽  
Author(s):  
Magdalena Kirsten ◽  
Ragai Edward Matta ◽  
Renan Belli ◽  
Ulrich Lohbauer ◽  
Manfred Wichmann ◽  
...  

2019 ◽  
Vol 13 (02) ◽  
pp. 178-186
Author(s):  
Fabiana S. A. S. Camargo ◽  
Alejandra H. M. González ◽  
Roberta C. B. Alonso ◽  
Vinicius Di Hipólito ◽  
Paulo H. P. D'Alpino

Abstract Objective The aim of the study was to evaluate the physicochemical properties of self-adhesive resin cements associated with hydroxyapatite (HAp) according to the polymerization activation. Materials and Methods Specimens of cements (PermaCem 2.0 [DMG]; MaxCem Elite [Kerr], and RelyX U200 [3M ESPE]) were distributed into three groups: activation mode; self-cured and dual-cured modes; and association or not with HAp powder mode. The pH neutralization was evaluated as a function of time. Flexural strength and elastic modulus were also tested (0.5 mm/min.). The depth of cure was also analyzed using the scraping test (ISO 4049). Infrared spectroscopy was also used to collect the spectra of specimens to evaluate the chemical bonds. Statistical comparisons were conducted at 5% of significance. Results The aggressiveness of the self-adhesive resin cements evaluated varied among the materials with a tendency for neutralization. Self-cure groups exhibited lower pH throughout the entire evaluation when compared with that of the dual-cure ones, irrespective of the addition of HAp. MaxCem Elite when photoactivated was the only cement influenced by the addition of the HAp in terms of mechanical properties. The self-adhesive cements tested presented equivalent depth of cure based on the ISO 4049 requirements, regardless of the evaluated factors. Conclusions Based on the parameters evaluated, the results demonstrated that most of the self-adhesive cements remained unaltered or improved when mixed with HAp, regardless of the activation mode.


2016 ◽  
Vol 41 (3) ◽  
pp. 327-338 ◽  
Author(s):  
T Takamizawa ◽  
WW Barkmeier ◽  
MA Latta ◽  
TP Berry ◽  
A Tsujimoto ◽  
...  

SUMMARY One of the primary areas of concern with luting agents is marginal gap erosion and attrition. The purpose of this laboratory study was to evaluate bulk and marginal slit (gap) generalized wear of self-adhesive resin cements. Three self-adhesive resin cements were used in this study: G-CEM LinkAce (LA), Maxcem Elite (ME), and RelyX Unicem2 Automix (RU). A custom stainless-steel fixture with a cavity 4.5 mm in diameter and 4 mm deep was used for simulated generalized (bulk) wear. For simulated marginal gap wear, a two-piece stainless-steel custom fixture was designed with a slit (gap) 300 μm wide and 3 mm in length. For both wear models, 20 specimens each for each of the three adhesive cements were made for both light-cure and chemical-cure techniques. The cured cements were polished with a series of carbide papers to a 4000-grit surface and subjected to 100,000 cycles using the slit (gap) wear model and 400,000 cycles for generalized (bulk) wear in a Leinfelder-Suzuki (Alabama machine) wear simulator (maximum load of 78.5 N). Flat-ended stainless-steel antagonists were used in a water slurry of poly(methylmethacrylate) beads for simulation of generalized contact-free area wear with both wear models. Before and after the wear challenges, the specimens were profiled with a Proscan 2100 noncontact profilometer, and wear (volume loss [VL] and mean facet depth [FD]) was determined using AnSur 3D software. Two-way analysis of variance (ANOVA) and Tukey post hoc tests were used for data analysis for the two wear models. Scanning electron microscopy (SEM) was used to examine polished surfaces of the resin cements and the worn surfaces after the wear challenges. The two-way ANOVA of VL using the generalized (bulk) wear model showed a significant effect among the three resin cement materials for the factor of resin cement (p<0.001) and the interaction of the cement and cure method (p<0.001), but not for the cure method (p=0.465). The two-way ANOVA for FD also found a significant difference for the factor of resin cement (p<0.001) and the interaction of the resin cement and cure method (p<0.001), but not for the cure method (p=0.277). The simulated generalized (bulk) wear for the light-cure groups was as follows: VL (mm3): RU 0.631 (0.094), LA 0.692 (0.112), and ME 1.046 (0.141) and FD (μm): RU 43.6 (6.5), LA 47.0 (7.7), and ME 72.5 (9.9). The simulated generalized (bulk) wear for the chemical-cure groups was as follows: VL (mm3): LA 0.741 (0.105), RU 1.231 (0.234), and ME 1.305 (0.143) and FD (μm): LA 50.7 (7.2), RU 84.5 (16.1), and ME 91.7 (10.2). Simulated wear using the slit (gap) model for the light-cure groups was as follows: VL (mm3): RU 0.030 (0.006), LA 0.031 (0.006), and ME 0.041 (0.009) and FD (μm): RU 49.6 (5.7), LA 57.2 (8.4), and ME 70.9 (10.7). The wear values for the chemical-cure slit (gap) groups were as follows: VL (mm3): LA 0.031 (0.004), ME 0.038 (0.007), and RU 0.045 (0.009) and FD (μm): LA 53.9 (6.7), ME 63.5 (9.1), and RU 74.2 (12.9). Pearson correlation tests revealed a strong relationship between the two wear models for the light-cure groups and a good relationship for the chemical-cure groups. The observations using SEM showed differences in filler particle shape and size among the cements and the resultant effect of the wear challenges. The worn surfaces of each cement were essentially the same for both light-cure and chemical-cure methods. The bulk wear model and new slit (gap) model for evaluation of simulated generalized wear of luting agents demonstrated significant differences (p<0.05) in relative wear among three self-adhesive resin cements and between visible light- and chemical-cure techniques.


2011 ◽  
Vol 36 (6) ◽  
pp. 635-642 ◽  
Author(s):  
RR Moraes ◽  
N Boscato ◽  
PS Jardim ◽  
LFJ Schneider

Clinical Relevance Self-adhesive resin cements present slower polymerization and lower degree of conversion than conventional resin cements, in either the dual- or self-cure mode.


2013 ◽  
Vol 14 (4) ◽  
pp. 675-680
Author(s):  
Khalil Aleisa

ABSTRACT Statement of the problem Post retention is crucial factor in restoration survival. Posts are commonly failed due to loss of retention. It is unknown which luting agents would provide the maximum bond strength for Locator overdenture posts. Aim The aim of this study was to evaluate the bond retentive strengths of Locator overdenture posts cemented with 7 luting agents. Materials and methods One hundred and five single rooted human teeth were decoronated and randomly assigned to 7 groups (n = 15). Post spaces were prepared with Locator post drills to the depth of 6 mm. The Locator posts were cemented with Variolink II, RelyX ARC, Multilink N, RelyX Unicem, ParaCore, or MultiCore Flow resin luting agents. Zinc phosphate cement was served as control group. Specimens were stored in water at 37°C for 24 hours. Each specimen was loaded in tension in an Instron universal testing machine. The maximum force required to dislodge each Locator post was recorded. Means and standard deviations were calculated and data were statistically analyzed with one-way analysis of variance (ANOVA). Results The highest mean bond strength value for Locator posts was recorded for MultiCore® Flow group (mean = 550.1 N), while the lowest mean value was for RelyX Unicem™ resin cement group (mean = 216.8 N). A statistically significant difference in mean locator overdenture post bond strength was observed between the 7 cement types (p < 0.0001). ParaCore™ and MultiCore® Flow groups had significantly higher bond strength than all other groups, but they were not differed from each other. Conclusion Bond strength of Locator overdenture posts were influenced by the type of luting agents. MultiCore Flow and ParaCore resin cements offered the greatest retention. Clinical significance The type of luting agents had a significant effect on the retention of Locator posts. The use of Core buildup resin cements as luting agent with Locator post demonstrated the greatest retention. How to cite this article Aleisa K. Bond Strength of Overdenture Locator Posts Cemented with Seven Luting Agents. J Contemp Dent Pract 2013;14(4):675-680.


2015 ◽  
Vol 16 (7) ◽  
pp. 559-564 ◽  
Author(s):  
Matheus Coelho Bandéca ◽  
Adriano Augusto Melo de Mendonça ◽  
Etevaldo Matos Maia Filho ◽  
Fausto da Silva Bramante ◽  
Darlon Martins Lima ◽  
...  

ABSTRACT This study evaluated the influence of relining fiber posts on the bond strength (BS) of resin cements in the root canal. Forty bovine teeth were divided in four groups (n = 10)G1 (ARC)—fiber post cemented with resin cement RelyX ARC; G2 (ARC+Z350)—relined fiber post cemented with RelyX ARC; G3 (U200)—fiber post cemented with self-adhesive cement RelyX U200; G4 (U200+Z350)—relined fiber post cemented with RelyX U200. The roots were sectioned in six 1.2-mm slices and the push-out test was performed. Data were analyzed by three-way analysis of variance (ANOVA), and Tukey's test (α = 0.05). For the conventional resin cement, there was no significant difference between groups G1-ARC (15.5 ± 3.8) and G2-ARC+Z350 (16.1 ± 4.5). For the self-adhesive cement, the results revealed higher BS values for relined posts G4-U200 + Z350 (19.9 ± 7.9) as compared to non-relined posts G3-U200 (14.4 ± 4.5). For both cements, in groups of relined posts, the apical and the cervical thirds presented similar BS. Relining enhances the performance of the self-adhesive resin cement, and the interaction between relining and root third influences the BS to the conventional resin cement. How to cite this article Conde DM, Rodrigues VP, de Fátima Carvalho Souza S, Bauer JRO, da Silva Bramante F, Lima SNL, Filho EMM, Bandeca MC, de Mendonça AAM, Lima DM. Influence of Relining Post on the Bond Strength of Resin Cements. J Contemp Dent Pract 2015;16(7):559-564.


Sign in / Sign up

Export Citation Format

Share Document