Long-term Test-Retest Reliability of Category Loudness Scaling in Normal-Hearing Subjects Using Pure-tone Stimuli

1998 ◽  
Vol 27 (3) ◽  
pp. 161-167 ◽  
Author(s):  
Arne N. Rasmussen ◽  
Steen Ø. Olsen ◽  
Britt V. Borgkvist ◽  
Lars H. Nielsen
1982 ◽  
Vol 25 (4) ◽  
pp. 521-527 ◽  
Author(s):  
David C. Shepherd

In 1977, Shepherd and colleagues reported significant correlations (–.90, –.91) between speechreading scores and the latency of a selected negative peak (VN 130 measure) on the averaged visual electroencephalic wave form. The primary purpose of this current study was to examine the stability, or repeatability, of this relation between these cognitive and neurophysiologic measures over a period of several months and thus support its test-retest reliability. Repeated speechreading word and sentence scores were gathered during three test-retest sessions from each of 20 normal-hearing adults. An average of 56 days occurred from the end of one to the beginning of another speechreading sessions. During each of four other test-retest sessions, averaged visual electroencephalic responses (AVER s ) were evoked from each subject. An average of 49 clays intervened between AVER sessions. Product-moment correlations computed among repeated word scores and VN l30 measures ranged from –.61 to –.89. Based on these findings, it was concluded that the VN l30 measure of visual neural firing time is a reliable correlate of speech-reading in normal-hearing adults.


1993 ◽  
Vol 162 (S19) ◽  
pp. 25-29 ◽  
Author(s):  
Graham Thornicroft ◽  
Christopher Gooch ◽  
Catherine O'Driscoll ◽  
Sawsan Reda

The development of the hospital and community versions of the Patient Attitude Questionnaire is described. The instrument rates the attitudes of psychiatric patients towards their treatment settings and staff, and is framed specifically to assess attitudinal change during the transfer of patients from hospital. For the items rated using the kappa coefficient of agreement, the mean test-retest reliability value was 0.51, and the average inter-rater value was 0.82. This study shows that long-term psychiatric patients are able to give clear and consistent views about their living arrangements - views that should be sought and respected by staff.


Author(s):  
Hannah Keppler ◽  
Sofie Degeest ◽  
Bart Vinck

Purpose The objective of the current study was to investigate the short-term test–retest reliability of contralateral suppression (CS) of click-evoked otoacoustic emissions (CEOAEs) using commercially available otoacoustic emission equipment. Method Twenty-three young normal-hearing subjects were tested. An otoscopic evaluation, admittance measures, pure-tone audiometry, measurements of CEOAEs without and with contralateral acoustic stimulation (CAS) to determine CS were performed at baseline ( n = 23), an immediate retest without and with refitting of the probe (only CS of CEOAEs; n = 11), and a retest after 1 week ( n = 23) were performed. Test–retest reliability parameters were determined on CEOAE response amplitudes without and with CAS, and on raw and normalized CS indices between baseline and the other test moments. Results Repeated-measures analysis of variance indicated no random or systematic changes in CEOAE response amplitudes without and with CAS, and in raw and normalized CS indices between the test moments. Moderate-to-high intraclass correlation coefficients with mostly high significant between-subjects variability between baseline and each consecutive test moment were found for CEOAE response amplitude without and with CAS, and for the raw and normalized CS indices. Other reliability parameters deteriorated between CEOAE response amplitudes with CAS as compared to without CAS, between baseline and retest with probe refitting, and after 1 week, as well as for frequency-specific raw and normalized CS indices as compared to global CS indices. Conclusions There was considerable variability in raw and normalized CS indices as measured using CEOAEs with CAS using commercially available otoacoustic emission equipment. More research is needed to optimize the measurement of CS of CEOAEs and to reduce influencing factors, as well as to make generalization of test–retest reliability data possible.


2015 ◽  
Vol 35 (7) ◽  
pp. 1199-1205 ◽  
Author(s):  
Kati Alakurtti ◽  
Jarkko J Johansson ◽  
Juho Joutsa ◽  
Matti Laine ◽  
Lars Bäckman ◽  
...  

We measured the long-term test–retest reliability of [11C]raclopride binding in striatal subregions, the thalamus and the cortex using the bolus-plus-infusion method and a high-resolution positron emission scanner. Seven healthy male volunteers underwent two positron emission tomography (PET) [11C]raclopride assessments, with a 5-week retest interval. D2/3 receptor availability was quantified as binding potential using the simplified reference tissue model. Absolute variability (VAR) and intraclass correlation coefficient (ICC) values indicated very good reproducibility for the striatum and were 4.5%/0.82, 3.9%/0.83, and 3.9%/0.82, for the caudate nucleus, putamen, and ventral striatum, respectively. Thalamic reliability was also very good, with VAR of 3.7% and ICC of 0.92. Test-retest data for cortical areas showed good to moderate reproducibility (6.1% to 13.1%). Our results are in line with previous test–retest studies of [11C]raclopride binding in the striatum. A novel finding is the relatively low variability of [11C]raclopride binding, providing suggestive evidence that extrastriatal D2/3 binding can be studied in vivo with [11C]raclopride PET to be verified in future studies.


2013 ◽  
Vol 89 (1) ◽  
pp. 106-114 ◽  
Author(s):  
Jan Ferenc Brunner ◽  
Tor Ivar Hansen ◽  
Alexander Olsen ◽  
Toril Skandsen ◽  
Asta Håberg ◽  
...  

2015 ◽  
Vol 111 ◽  
pp. 55-59 ◽  
Author(s):  
Andrey P. Anokhin ◽  
Simon Golosheykin ◽  
Richard C. Mulligan

2005 ◽  
Vol 16 (08) ◽  
pp. 585-595 ◽  
Author(s):  
Melissa N. Ruscetta ◽  
Catherine V. Palmer ◽  
John D. Durrant ◽  
Judith Grayhack ◽  
Carey Ryan

Psychometric evaluations were performed on a self-perceived localization disabilities and handicaps questionnaire. Twenty individuals with normal hearing bilaterally, twenty with profound unilateral hearing impairment (UHI), and ten with any degree of bilateral hearing impairment participated. Each subject completed the questionnaire. Comparisons of the responses of the subjects with normal hearing and those with UHI revealed significant differences among the groups for both disabilities and handicaps, establishing construct validity. Cronbach's Alpha correlational analyses of the responses of all subjects with hearing impairment revealed correlations of .900 (disabilities) and .800 (handicaps), establishing internal consistency. Each participant with hearing impairment was asked to complete the questionnaire again after three weeks. Pearson's correlational analyses of the responses at time one versus time two revealed correlations of .900 (disabilities) and .700 (handicaps), establishing test/retest reliability. This questionnaire is an appropriate tool for investigating the self-perceived localization disabilities and handicaps of individuals with hearing impairment.


Sensors ◽  
2018 ◽  
Vol 18 (7) ◽  
pp. 1980 ◽  
Author(s):  
Wolfgang Teufl ◽  
Markus Miezal ◽  
Bertram Taetz ◽  
Michael Fröhlich ◽  
Gabriele Bleser

Sign in / Sign up

Export Citation Format

Share Document