Acetic acid modified zinc oxide nanoparticles for solid phase extraction of Cu(II) and Cr(III) in water

Author(s):  
Asnake Tesfaye ◽  
Meseret Amde ◽  
Endale Teju ◽  
Deribachew Bekana ◽  
Negussie Megersa
2008 ◽  
Vol 27 (1) ◽  
pp. 25 ◽  
Author(s):  
Aleksandra Nestorovska-Krsteska ◽  
Meri Mirčeska ◽  
Jean-Jacques Aaron ◽  
Zoran Zdravkovski

An HPLC-UVDAD method for determination of dimethoate, 2,4-dichlorophenoxy acetic acid (2,4-D), mecoprop (MCPP) and linuron in environmental waters was developed. The water samples were concentrated and extracted by a solid phase extraction (SPE) method on Bond Elut PPL cartridges. After extraction the investigated compounds were separated on Stability RP Pesticides chromatographic column using mobile phase composed of acetonitrile- water-acetic acid in volume fractions of 39:59:2 and flow rate of 0.7 mL/min. Ultraviolet absorption detection was carried out for dimethoate, 2,4-D and MCPP at 229 nm, and for linuron at 249 nm. Recoveries made from 500 mL of drinking waters using solid phase extraction ranged between 64.3–92.1 %. The method was applied to environmental waters in Macedonia that receive runoffs from agriculture lands. The levels of pesticides under study ranged between 0.31 μg/L and 7.05 μg/L, depending on the compound and sampling period.


Molecules ◽  
2021 ◽  
Vol 26 (20) ◽  
pp. 6163
Author(s):  
Aree Choodum ◽  
Nareumon Lamthornkit ◽  
Chanita Boonkanon ◽  
Tarawee Taweekarn ◽  
Kharittha Phatthanawiwat ◽  
...  

Benzo(a)pyrene (BaP) has been recognized as a marker for the detection of carcinogenic polycyclic aromatic hydrocarbons. In this work, a novel monolithic solid-phase extraction (SPE) sorbent based on graphene oxide nanoparticles (GO) in starch-based cryogel composite (GO-Cry) was successfully prepared for BaP analysis. Rice flour and tapioca starch (gel precursors) were gelatinized in limewater (cross-linker) under alkaline conditions before addition of GO (filler) that can increase the ability to extract BaP up to 2.6-fold. BaP analysis had a linear range of 10 to 1000 µgL−1 with good linearity (R2 = 0.9971) and high sensitivity (4.1 ± 0.1 a.u./(µgL−1)). The limit of detection and limit of quantification were 4.21 ± 0.06 and 14.04 ± 0.19 µgL−1, respectively, with excellent precision (0.17 to 2.45%RSD). The accuracy in terms of recovery from spiked samples was in the range of 84 to 110% with no significant difference to a C18 cartridge. GO-Cry can be reproducibly prepared with 2.8%RSD from 4 lots and can be reused at least 10 times, which not only helps reduce the analysis costs (~0.41USD per analysis), but also reduces the resultant waste to the environment.


Sign in / Sign up

Export Citation Format

Share Document