scholarly journals Performance of a new device for the clinical determination of light discomfort

2020 ◽  
Vol 17 (11) ◽  
pp. 1221-1230
Author(s):  
Robert Montés-Micó ◽  
Alejandro Cerviño ◽  
Noelia Martínez-Albert ◽  
José V. García-Marqués ◽  
Sarah Marie
Author(s):  
Sanaa Aljamani ◽  
Callum Youngson ◽  
Fadi Jarad ◽  
Francis O’Neill

Abstract Purpose Recently we described mapping of the lingual nerve clinically in patients using electrical nerve stimulation. This paper reports results of a larger study with inter- and intra-observer reliability and comparison with positional measurements from magnetic resonance imaging (MRI). Methods In 50 healthy participants, measurements were taken when subjects felt a tingling sensation in the tongue induced by a stimulation probe over the lingual nerve. Three positions were measured in relation to the third molar. Measurement reliability was tested for both inter-observer and intra-observer agreement and positional data of the lingual nerve measured clinically was also compared with nerve position as measured from MRI scans. Results Out of 50 participants, 96 nerves (49 = left/47 = right) were included in the study. The lingual nerve was identified in 90% (87) of this sample. The mean of height of the nerve in points A, B and C were 9.64 mm, 10.77 mm and 12.34 respectively. Inter-and intra-observer agreement was considered to be good to excellent (ICC = 0.8–0.96). Agreement between nerve mapping measured values and MRI measured values was good (ICC < 0.6). Conclusion This technique may prove useful for the clinical determination of lingual nerve position prior to procedures in the third molar region.


2005 ◽  
Vol 93 (9-10) ◽  
Author(s):  
Dorothea Schumann ◽  
R. Grasser ◽  
R. Dressler ◽  
H. Bruchertseifer

SummaryA new device was developed for the identification of several iodine species in aqueous solution using ion chromatography. Iodide, iodate and molecular iodine can be determined. (The equipment allows both conductivity and radioactivity detections.) The method is applicable for the determination of radioactive iodine contaminations in the cooling water of nuclear power plants.


2018 ◽  
Vol 27 (4) ◽  
pp. 250-5
Author(s):  
Sultan A.M. Saghir ◽  
Amer A. Almaiman ◽  
Aishah K.A. Shatar ◽  
Norris Naim ◽  
Huda S. Baqir

Background: The fast and outpatient setting for a determination of the hemoglobin (Hb) level is a well-recognized prerequisite to detect anemia in blood donors. This study aimed to evaluate the performance of the HemoCue methods (HemoCue B-Hb and HemoCue-301) against Coulter LH-750 as a reference method for Hb determination.Methods: This study was an experimental cross-sectional study. It includes 455 blood samples that were collected from volunteer blood donors between January 15, 2010 and February 15, 2011. The performance of the three methods and their comparisons were assessed using the analysis of coefficients of variation (CV), linear regression, and mean difference. Correlation coefficient and Bland–Altman plots were drawn to compare the two HemoCue measurements and the automated cell analyzer against each other and to evaluate their results. The Hb concentrations were compared using the concordance correlation coefficient.Results: The findings exhibited that the CV for the three methods Coulter LH-750, HemoCue B-Hb, and HemoCue-301 were 0.60%, 0.72%, and 0.92%, respectively. A statistically significant difference was observed between the means of the Hb measurements for the three methods (p<0.001). The HemoCue B-Hb and HemoCue-301 methods showed the best agreement, and the Coulter LH-750 method gave a lower Hb value compared with the two HemoCue methods. The results showed a positive correlation of HemoCue Hb results compared with the reference method.Conclusion: All three methods provide a good agreement for Hb determination. The new device HemoCue-301 was found to be more accurate compared with HemoCue B-Hb and Coulter LH-750.


2019 ◽  
pp. 75-79
Author(s):  
Oleksandr Holoviy

The article describes the design of the device for determining the fiber content in individual plants of flax, which is a special torsion scales of the new design. The principle of operation of the device is based on the transformation of the free end of the cantilever-mounted flat spring, to which the object of suspension is suspended, in the rotation of a mirror that reflects the laser diode beam on the scale. The device can be used in fibe flax breeding.


2012 ◽  
Vol 65 (5-6) ◽  
pp. 217-222 ◽  
Author(s):  
Ljiljana Strajnic ◽  
Darinka Stanisic-Sinobad

Introduction. Optimal reconstruction of vertical dimension of occlusion is crucial for functional and physiognomic rehabilitation of edentulous patients. This article is aimed at presenting attitudes and studies on application of cephalometric analysis in obtaining optimal vertical dimension of occlusion. The review of literature presents the studies which analyse the possibilities of cephalometric analysis aimed at improving the clinical methods for vertical dimension of occlusion determination in treatment of edentulous patients. The research carried out so far can roughly be divided into: cephalometric vertical dimension of occlusion evaluation in dentulous patients performed to determine precise indicators of vertical dimension of occlusion and to establish cephalometric standards for practical application in prosthodontics; the method of producing pre-extraction cephalometric registries involves the production of cephalometric radiographs for potential prosthodontic patients in dental pre-extraction period which are kept for reference to be used in later therapy; the cephalometric method of registering the position of physiologic rest position of the mandible involves measuring cephalometric parameters in cephalometric radiographs made when the mandible is in physiologic rest position; cephalometric evaluation of vertical dimension of occlusion in complete denture therapy after clinical determination of intemaxillary relationship is recommended for timely detection of possible mistakes, with a possibility of correction in the process of complete denture production; and cephalometric analysis in edentulous patients with old complete dentures for a planned vertical dimension of occlusion extension. Conclusion. Data from the literature give no proof of a scientific and universally accepted method for precise determination of vertical dimension of occlusion, which is a point many authors agree upon. Different methods proposed for vertical dimension of occlusion determination in everyday practice are usually recommended in combination with other methods. Determination of individual, morphological vertical dimension of occlusion indicators by cephalometric analysis is, in this sense, one of the directions for finding a better solution when planning an artificial occlusion complex.


2021 ◽  
Vol 49 (04) ◽  
pp. 229-233
Author(s):  
Isatay Jakupov ◽  
Zhanargul Karabayeva ◽  
Aida Abultdinova

Abstract Objective An important task of veterinarians in cattle husbandry is the early diagnosis of postpartum complications that can lead to infertility. The aim of the study was the evaluation of a new device to distinguish between physiological and pathological conditions of the uterus based on the determination of the time of uterine involution and the physicochemical properties of the vaginal discharge (lochia) during the first weeks after parturition. Material and methods A total of 173 black-and-white Holstein-Friesian dairy cows were examined for any pathological alteration of the uterine involution on days 1–2, 6–8, 11–14 postpartum and, in case of pathological findings, additionally on days 18–22, 23–27 and 28–30 after parturition. In addition to the standard examination a newly developed hand-held instrument (“Metrastatum”) was used to differentiate between physiological and pathological uterine involution. It allows determination of the distance between the cervix and vulva (DCV) and simultaneous collection of lochial secretions. Results The best time to use the new instrument was 10–16 days postpartum. In healthy cows without disturbed puerperium, the average DCV was 25.7 cm (± 0.8 cm) in this phase. This distance decreased by 12.5 ± 0.3 cm compared to the first days. In contrast, in cows with postpartum problems, the DCV was significantly greater at (31 ± 0.7 cm) (p < 0.001). In these animals, the AGV was reduced only by an average of 8.4 ± 0.6 cm when compared to the first days. The mucus obtained with the dome-shaped rubber funnel of the instrument also differed in the cows of the 2 groups. In healthy cows without puerperal problems, the lochia were thick, colorless, transparent and sometimes cloudy. In case of puerperal disorders, the discharge was thin, light red to reddish brown, contained flakes and had a nasty odor depending on the form of the inflammation. Conclusion The dual function of device helps to early diagnose puerperal disorders in cows and to select healthy animals for reproduction and sick cows for treatment depending on the form of uterine inflammation.


Sign in / Sign up

Export Citation Format

Share Document