Operation and grid interaction modeling of a house with a building integrated photovoltaic thermal (BIPV/T) system coupled to an air-source heat pump

Author(s):  
Remi Dumoulin ◽  
Efstratios Dimitrios Rounis ◽  
Andreas Athienitis
2021 ◽  
Author(s):  
Raghad Sabah Kamel

A TRNSYS model was developed to conduct a comprehensive study of combining a building integrated photovoltaic thermal (BIPV/T) collector with an air source heat pump (ASHP) in an Archetype Sustainable House. The heat pump uses the warm air generated in the BIPV/T as the source for heat production. The coupling of BIPV/T and ASHP enables a highly efficient heating system in winter conditions. A numerical model was developed for an air-based PV/T collector. The model was used to predict the thermal and electrical performance of the collector and to conduct a comprehensive analysis for different configurations (number of PV/T panels in rows NR and in series NS) and different design parameters. TRNSYS simulation results showed that low air mass flow rate and low duct depth enhance the heat pump coefficient of performance (COP). The arrangement with a large number of PV/T systems connected in series has higher COP. The maximum obtained seasonal heating COP was 3.45, corresponding to duct depth of 1.5 in, NS=5 and low row mass flow rate of 0.03 kg/s. The heat pump cumulative electricity consumption for a typical heating season could be reduced by 20.2%. When the analysis was based only on sunny hours, the electricity consumption of the combined ASHP + PV/T system was reduced by 52% and the predicted seasonal COP of the heat pump was 5.98. A new full-scale test facility was presented to be implemented at Toronto and Region Conservation Authority to examine the performance of combining passive system and dynamic building envelope technologies (BIPV/T+ASHP+TES) under real weather conditions. It is important to match the maximum airflow for the BIPV/T system with the maximum airflow for the outdoor coil of the heat pump. The pressure drop inside the PV/T collector along with the connecting air duct from the BIPV/T to ASHP for a wide range of airflow rates and different duct depths was calculated. It was found that for air a flow rate around 2000 CFM, which is the maximum CFM for the custom-made ASHP for the test facility, the predicted fan energy was 195 kWh/year corresponding to 1.5 in. duct depth.


Author(s):  
Getu Hailu ◽  
Peter Dash ◽  
Alan S. Fung

A theoretical investigation of a variable capacity air-to-air air source heat pump (VC-ASHP) coupled with a building integrated photovoltaic/thermal (BIPV/T) system is presented in this paper. The BIPV/T system was integrated into the roof and the wall. Air was circulated behind the photovoltaic arrays to recover the thermal energy. The warm air recovered was supplied to the VC-ASHP. The thermal performance of the VC-ASHP was investigated for three scenarios when the heat pump is running in heating mode. The three scenarios are: (A) by feeding the ambient air to the ASHP; (B) by coupling the ASHP to the wall integrated BIPV/T only; and (C) by coupling the ASHP to the roof integrated BIPV/T only. The coefficient of performance (COP) of the VC-ASHP was evaluated for these three separate scenarios and compared. A typical winter day result suggests that the COP of the ASHP can be improved by coupling the VC-ASHP to either of the BIPV/T systems, i.e., either to the roof integrated BIPV/T system or to the wall integrated BIPV/T system.


2021 ◽  
Author(s):  
Ali Karevan

In recent years, an increased focus has been given to replacing high Global Warming Potential (GWP) refrigerants with relatively low GWP alternatives. Energy efficiency, carbon reduction and HFC phase-down will push the heat pump market towards natural refrigerants. Propane (R-290) is a type of hydrocarbon refrigerant with zero ozone depletion potential and very low GWP (< 4). R-290 is a pure refrigerant and has excellent thermodynamic properties. The research presented in this project is a study of the refrigerant side of an ASHP to analyze the thermodynamic performance of the propane refrigerant under different operating conditions. For this purpose, a test rig was designed and constructed in a single packaged air source heat pump unit. In addition, the air side of the tested heat pump was designed for energy recovery in cooling and heating modes. The compactness of the system and installation of air dampers allows its placement for coupling to the building renewable air sources, such as a building integrated photovoltaic/thermal (BIPV/T) system.


2021 ◽  
Author(s):  
Raghad Sabah Kamel

A TRNSYS model was developed to conduct a comprehensive study of combining a building integrated photovoltaic thermal (BIPV/T) collector with an air source heat pump (ASHP) in an Archetype Sustainable House. The heat pump uses the warm air generated in the BIPV/T as the source for heat production. The coupling of BIPV/T and ASHP enables a highly efficient heating system in winter conditions. A numerical model was developed for an air-based PV/T collector. The model was used to predict the thermal and electrical performance of the collector and to conduct a comprehensive analysis for different configurations (number of PV/T panels in rows NR and in series NS) and different design parameters. TRNSYS simulation results showed that low air mass flow rate and low duct depth enhance the heat pump coefficient of performance (COP). The arrangement with a large number of PV/T systems connected in series has higher COP. The maximum obtained seasonal heating COP was 3.45, corresponding to duct depth of 1.5 in, NS=5 and low row mass flow rate of 0.03 kg/s. The heat pump cumulative electricity consumption for a typical heating season could be reduced by 20.2%. When the analysis was based only on sunny hours, the electricity consumption of the combined ASHP + PV/T system was reduced by 52% and the predicted seasonal COP of the heat pump was 5.98. A new full-scale test facility was presented to be implemented at Toronto and Region Conservation Authority to examine the performance of combining passive system and dynamic building envelope technologies (BIPV/T+ASHP+TES) under real weather conditions. It is important to match the maximum airflow for the BIPV/T system with the maximum airflow for the outdoor coil of the heat pump. The pressure drop inside the PV/T collector along with the connecting air duct from the BIPV/T to ASHP for a wide range of airflow rates and different duct depths was calculated. It was found that for air a flow rate around 2000 CFM, which is the maximum CFM for the custom-made ASHP for the test facility, the predicted fan energy was 195 kWh/year corresponding to 1.5 in. duct depth.


2021 ◽  
Author(s):  
Ali Karevan

In recent years, an increased focus has been given to replacing high Global Warming Potential (GWP) refrigerants with relatively low GWP alternatives. Energy efficiency, carbon reduction and HFC phase-down will push the heat pump market towards natural refrigerants. Propane (R-290) is a type of hydrocarbon refrigerant with zero ozone depletion potential and very low GWP (< 4). R-290 is a pure refrigerant and has excellent thermodynamic properties. The research presented in this project is a study of the refrigerant side of an ASHP to analyze the thermodynamic performance of the propane refrigerant under different operating conditions. For this purpose, a test rig was designed and constructed in a single packaged air source heat pump unit. In addition, the air side of the tested heat pump was designed for energy recovery in cooling and heating modes. The compactness of the system and installation of air dampers allows its placement for coupling to the building renewable air sources, such as a building integrated photovoltaic/thermal (BIPV/T) system.


Author(s):  
Raghad S. Kamel ◽  
Alan S. Fung

TRNSYS simulation software was used to modify a validated Air Source Heat Pump (ASHP) model in an Archetype Sustainable House (ASH) in Toronto. In this model, a Building Integrated Photovoltaic-Thermal Collector (BIPV/T) was coupled with ASHP. The PV/T system arrangement was considered as a part of the south-oriented roof of the house. The warm air generated in the BIPV/T collector was considered the source of the heat pump for heat production. The coupling of BIPV/T and ASHP enables a highly efficient heating system in harsh winter conditions. The developed TRNSYS model of the house along with integrated PV/T system with ASHP was simulated for the whole year to predict the hourly outlet air temperature, thermal energy and electricity obtained from the PV/T array. The results from the simulation were used to estimate the saving in energy and cost as well as to predict the electricity related GHG emission reduction potential from the PV panels. Monthly greenhouse gas (GHG) emission credit from PV production based on hourly GHG emission factor was obtained; the results showed that annual GHG emission due to electricity demand by the ASHP was reduced by 225 kg CO2 (19.3%) when the heat pump was integrated with the PV/T array. Also, in this study, the annual electricity cost credit from PV production based on Time-of-Use (TOU) and the reduction in electricity cost of the heat pump when connected with PV/T systems was calculated and compared with the cost of working the heat pump alone. The results show that there is a saving of $500 in annual electricity bills and GHG emission credit of 862.6 kg CO2 from renewable electricity generation.


2020 ◽  
Vol 180 ◽  
pp. 107029
Author(s):  
Pin Wu ◽  
Zhichao Wang ◽  
Xiaofeng Li ◽  
Zhaowei Xu ◽  
Yingxia Yang ◽  
...  

Energies ◽  
2021 ◽  
Vol 14 (5) ◽  
pp. 1321
Author(s):  
Yu-Jin Hwang ◽  
Jae-Weon Jeong

The objective of this research is to establish an appropriate operating strategy for a radiant floor heating system that additionally has an air source heat pump for providing convective air heating separately, leading to heating energy saving and thermal comfort in residential buildings. To determine the appropriate optimal operating ratio of each system taking charge of combined heating systems, the energy consumption of the entire system was drawn, and the adaptive floor surface temperature was reviewed based on international standards and literature on thermal comfort. For processing heating loads with radiant floor heating and air source heating systems, the heating capacity of radiant floor heating by 1 °C variation in floor temperature was calculated, and the remaining heating load was handled by the heating capacity of the convective air heating heat pump. Consequently, when the floor temperature was 25 °C, all heating loads were removed by radiant floor heating only. When handling all heating loads with the heat pump, 59.2% less energy was used compared with radiant floor heating only. Considering the local discomfort of the soles of the feet, the floor temperature is expected to be suitable at 22–23 °C, and 31.5–37.6% energy saving compared with those of radiant floor heating alone were confirmed.