Reference measurement procedure for the determination of electrolytes in human blood via ICP-OES measurement

Metrologia ◽  
2018 ◽  
Vol 55 (2) ◽  
pp. 245-253 ◽  
Author(s):  
D Grote-Koska ◽  
R Klauke ◽  
K Brand ◽  
G Schumann
2009 ◽  
Vol 14 (5) ◽  
pp. 263-267 ◽  
Author(s):  
Sébastien Sannac ◽  
Paola Fisicaro ◽  
Guillaume Labarraque ◽  
Florence Pannier ◽  
Martine Potin-Gautier

Author(s):  
Sergej V. Medvedevskikh ◽  
Vasilisa B. Baranovskaya ◽  
Maria Yu. Medvedevskikh ◽  
Maria P. Krasheninina ◽  
Anna S. Sergeeva

2021 ◽  
Vol 18 (1) ◽  
Author(s):  
Zhiliang Cai ◽  
Qiaoxuan Zhang ◽  
Ziqiang Xia ◽  
Songbai Zheng ◽  
Lilan Zeng ◽  
...  

An amendment to this paper has been published and can be accessed via the original article.


2019 ◽  
Vol 107 (2) ◽  
pp. 141-147 ◽  
Author(s):  
Iga Zuba ◽  
Halina Polkowska-Motrenko

Abstract Primary reference measurement procedure for Cr determination in biological samples by radiochemical neutron activation analysis (RNAA) has been elaborated. The procedure is based on quantitative and selective separation of chromium from neutron irradiated sample by column chromatography using MnO2-Resin and determination of 51Cr by γ-ray spectrometry. Quality components have been incorporated into the RNAA method which makes it possible to meet the requirements of the definition of ratio primary reference measurement procedure. The usefulness of the elaborated procedure to assign the certified values for Cr in new certified reference material (CRMs) based on animal tissues is demonstrated. The tentative certified values for Cr have been proposed for: MODAS M-4 Cormorant Tissue and M-5 Cod Tissue CRMs.


2012 ◽  
Vol 36 (1) ◽  
Author(s):  
Martin Kammel ◽  
Andreas Kummrow ◽  
Jörg Neukammer

AbstractAccurate determination of cell concentrations serves as a valuable tool to support medical diagnosis and therapy control, e.g., in haematology, immunology and transfusion medicine. Intra- and inter-laboratory comparability of measurement results is essential for patient safety. To derive the so-called “conventional quantity value” of a measurand as target value for intra- or inter-laboratory quality assurance and to establish a traceability chain to the international System of Units (SI), a primary reference measurement procedure is needed, defined as a procedure which includes a complete analysis of influence quantities and perturbing factors and a complete description of measurement uncertainties. We describe a primary reference measurement procedure for the determination of erythrocyte concentration, based on flow cytometric cell counting by impedance measurements. To correct for instrument- and sample-dependent counting loss due to random coincidences, dilution series are prepared. The reference quantity value of the cell concentration is derived by extrapolation to vanishing volume fraction of the sample in the measurement suspension. Typically, for erythrocyte and leucocyte concentrations respective uncertainties of approximately 0.75% and 2% are reached. Future developments concern the extension of the procedures validated for erythrocyte and leucocyte counting by including immunological staining and microscopic techniques.