scholarly journals Electric Machines Virtual Laboratory: Testing of DC Motor

2021 ◽  
Vol 2111 (1) ◽  
pp. 012041
Author(s):  
R Badarudin ◽  
D Hariyanto ◽  
M Ali ◽  
S Meunmany

Abstract This article describes the realization of testing the characteristics of a DC motor on Simulink as a virtual laboratory. Testing of DC motors based on real conditions in a physical laboratory by combining two DC machines coupled to shafts including DC motors and DC generators. The types of DC motors tested include separately excited DC motors, shunt DC motors, and series DC motors. The implementation of the Simulink model adopts the wiring diagram in the real test. The test procedure is also adopted on the real test procedure. The data from the test results are made in DC motor characteristics graph. Virtual laboratory using Simulink can be used to realize DC motor testing, including test procedures, running no-load DC motors, increasing the load of DC motors with infinitely simulation features on Simulink. The results of the study show the characteristics of the experimental data for all types of DC motors tested according to the theory.

1974 ◽  
Vol 32 (02/03) ◽  
pp. 483-491
Author(s):  
E. A Loeliger ◽  
M. J Boekhout-Mussert ◽  
L. P van Halem-Visser ◽  
J. D. E Habbema ◽  
H de Jonge

SummaryThe present study concerned the reproducibility of the so-called prothrombin time as assessed with a series of more commonly used modifications of the Quick’s onestage assay procedure, i.e. the British comparative reagent, homemade human brain thromboplastin, Simplastin, Simplastin A, and Thrombotest. All five procedures were tested manually on pooled lyophilized normal and patients’ plasmas. In addition, Simplastin A and Thrombotest were investigated semiautomatically on individual freshly prepared patients’ plasmas. From the results obtained, the following conclusions may be drawn :The reproducibility of results obtained with manual reading on lyophilized plasmas is satisfactory for all five test procedures. For Simplastin, the reproducibility of values in the range of insufficient anticoagulation is relatively low due to the low discrimination power of the test procedure in the near-normal range (so-called low sensitivity of rabbit brain thromboplastins). The reproducibility of Thrombotest excels as a consequence of its particularly easily discerned coagulation endpoint.The reproducibility of Thrombotest, when tested on freshly prepared plasmas using Schnitger’s semiautomatic coagulometer (a fibrinometer-liJce apparatus), is no longer superior to that of Simplastin A.The constant of proportionality between the coagulation times formed with Simplastin A and Thrombotest was estimated at 0.64.Reconstituted Thrombotest is stable for 24 hours when stored at 4° C, whereas reconstituted Simplastin A is not.The Simplastin A method and Thrombotest seem to be equally sensitive to “activation” of blood coagulation upon storage.


Author(s):  
Andrean George W

Abstract - Control and monitoring of the rotational speed of a wheel (DC motor) in a process system is very important role in the implementation of the industry. PWM control and monitoring for wheel rotational speed on a pair of DC motors uses computer interface devices where in the industry this is needed to facilitate operators in controlling and monitoring motor speed. In order to obtain the best controller, tuning the Integral Derifative (PID) controller parameter is done. In this tuning we can know the value of proportional gain (Kp), integral time (Ti) and derivative time (Td). The PID controller will give action to the DC motor control based on the error obtained, the desired DC motor rotation value is called the set point. LabVIEW software is used as a PE monitor, motor speed control. Keyword : LabView, Motor DC, Arduino, LabView, PID.


2019 ◽  
Vol 19 (4) ◽  
pp. 261-267
Author(s):  
Е. Yu. Mishalova ◽  
E. V. Gordeev ◽  
V. N. Lebedev ◽  
S. A. Melnikov ◽  
S. A. Nimirskaya ◽  
...  

Haemorrhagic fever caused by the Ebola virus is a highly hazardous infectious disease with a mortality rate of 50– 90 %. Heterologous immunoglobulins with a high virus-neutralizing titer are an important element of the WHO-endorsed set of measures for emergency prevention and treatment of the disease. Specific activity of these products is largely determined by their fractional composition, and, in particular, by molecular mass distribution (MMD). The size-exclusion-high-performance liquid chromatography (SEC-HPLC) has traditionally been used for determination of the MMD of the target protein in human immunoglobulin-based products. The use of this method for evaluation of molecular parameters of heterologous immunoglobulin requires confirmation of its specificity, accuracy and precision, and establishment of the chromatographic system suitability criteria in the context of a new test object.The aim of the study was to test the applicability of the SEC-HPLC method to the assessment of molecular parameters of anti-Ebola immunoglobulin derived from horse serum.Materials and methods: three batches of purified equine anti-Ebola immunoglobulin were used in the study. Normal equine and human immunoglobulins of the IgG isotype were used as reference standards. The HPLC test procedures described in the European Pharmacopoeia 9.6 and State Pharmacopoeia of the Russian Federation, 14th ed., were used for determination of monomers and other immunoglobulin fractions. An Agilent 1260 Infinity (Agilent, USA) HPLC system with a diode array detector and an Agilent Bio SEC-3 HPLC column were used for quality evaluation of the tested products.Results: the resolution factor between IgG monomer and dimer peaks (1.69 and 2.10), and the chromatographic column efficiency (>2000) make it possible to use the SEC-HPLC system for evaluation of molecular parameters of heterologous immunoglobulin. The study demonstrated reproducibility of the test procedure.Conclusions: the study confirmed the applicability of the SEC-HPLC procedure for evaluation of molecular parameters of anti-Ebola immunoglobulin derived from horse serum. It demonstrated the compliance of the purified immunoglobulin to the national and international quality requirements in terms of «Molecular parameters».


2021 ◽  
Vol 65 (1) ◽  
pp. 42-52
Author(s):  
Hamed Keshmiri Neghab ◽  
Hamid Keshmiri Neghab

The use of DC motors is increasingly high and it has more parameters which should be normalized. Now the calibration of each parameters is important for each motor, because it affects in its performance and accuracy. A lot of researches are investigated in this area. In this paper demonstrated how to estimate the parameters of a Nonlinear DC Motor using different Nonlinear Optimization techniques of fitting parameters to model, that called model calibration. First, three methods for calibration of a DC motor are defined, then unknown parameters of the mathematical model with the nonlinear optimization techniques for the fitting routines and model calibration process, are identified. In addition, three optimization techniques such as Levenberg-Marquardt, Constrained Nonlinear Optimization and Gauss-Newton, are compared. The goal of this paper is to estimate nonlinear parameters of a DC motor under uncertainty with nonlinear optimization methods by using LabVIEW software as an industrial software and compare the nonlinear optimization methods based on position, velocity and current. Finally, results are illustrated and comparison between these methods based on the results are made.


Author(s):  
Byamakesh Nayak ◽  
Sangeeta Sahu ◽  
Tanmoy Roy Choudhury

<p>This paper explains an adaptive method for estimation of unknown parameters of transfer function model of any system for finding the parameters. The transfer function of the model with unknown model parameters is considered as the adaptive model whose values are adapted with the experimental data. The minimization of error between the experimental data and the output of the adaptive model have been realised by choosing objective function based on different error criterions. Nelder-Mead optimisation Method is used for adaption algorithm. To prove the method robustness and for students learning, the simple system of separately excited dc motor is considered in this paper. The experimental data of speed response and corresponding current response are taken and transfer function parameters of  dc motors are adapted based on Nelder-Mead optimisation to match with the experimental data. The effectiveness of estimated parameters with different objective functions are compared and validated with machine specification parameters.</p>


The aim of the project is to develop a wheel chair which can be controlled by voice of the person. It is based on the speech recognition model. The project is focused on controlling the wheel chair by human voice. The system is intended to control a wheel seat by utilizing the voice of individual. The structure of this framework will be particularly valuable to the crippled individual and furthermore to the older individuals. It is a booming technology which interfaces human with machine. Smart phone device is the interface. This will allow the challenging people to move freely without the assistant of others. They will get a moral support to live independently .The hardware used are Arduino kit, Microcontroller, Wheelchair and DC motors. DC motor helps for the movement of wheel chair. Ultra Sonic Sensor senses the obstacles between wheelchair and its way.


2017 ◽  
Vol 8 (2) ◽  
pp. 323-330
Author(s):  
Rina Mirdayanti ◽  
Murni

The ability to use practical tools for students is a must in the basic Physics practical courses. In fact often happens is not adequate for laboratory tersediannya the implementation of practical, so that the process of teaching being constrained. To like the other problems like this needed a media device such as a software-based virtual lab simulations that can be used in the teaching of basic physics. This research aims to analyze the exact effort that can be done to overcome the lack of sedian laboratory equipment. This type of research is research use approach to the study of literature. The expected results of this literature is the emergence of an understanding of basic physics lab course in conducting with virtual laboratory as a means to address the issue of sedian in the real Labs. This virtual lab so that it can be the right solution for students and teachers in carrying out practical work.   Abstrak Kemampuan menggunakan alat-alat praktikum bagi siswa merupakan suatu keharusan dalam mata pelajaran Fisika Dasar. Pada kenyataannya yang sering terjadi adalah tidak tersediannya laboratorium yang memadai untuk pelaksanaan praktikum, sehingga proses praktikum menjadi terkendala. Untuk mensiasati permasalahan seperti ini dibutuhkan sebuah media seperti perangkat software laboratorium virtual berbasis simulasi yang bisa digunakan dalam praktikum  fisika dasar. Penelitian ini bertujuan untuk menganalisis upaya yang tepat yang dapat dilakukan untuk mengatasi ketidak-sedian  peralatan  laboratorium. Jenis penelitian yang gunakan adalah penelitian dengan pendekatan studi literatur. Hasil yang diharapkan dari literatur ini adalah munculnya pemahaman dalam melaksanakan praktikum fisika dasar dengan laboratorium virtual sebagai sarana untuk mengatasi persoalan ketidak-sedian laboratorium secara nyata. Sehingga laboratorium virtual ini dapat menjadi solusi yang tepat bagi siswa dan guru dalam melaksanakan praktikum. Kata kunci: Praktikum, Ilmu Sains, Laboratorium Virtual, Pemahaman Konsep


2017 ◽  
Vol 28 (4) ◽  
pp. 1019-1043 ◽  
Author(s):  
Shi-Fang Qiu ◽  
Xiao-Song Zeng ◽  
Man-Lai Tang ◽  
Wai-Yin Poon

Double sampling is usually applied to collect necessary information for situations in which an infallible classifier is available for validating a subset of the sample that has already been classified by a fallible classifier. Inference procedures have previously been developed based on the partially validated data obtained by the double-sampling process. However, it could happen in practice that such infallible classifier or gold standard does not exist. In this article, we consider the case in which both classifiers are fallible and propose asymptotic and approximate unconditional test procedures based on six test statistics for a population proportion and five approximate sample size formulas based on the recommended test procedures under two models. Our results suggest that both asymptotic and approximate unconditional procedures based on the score statistic perform satisfactorily for small to large sample sizes and are highly recommended. When sample size is moderate or large, asymptotic procedures based on the Wald statistic with the variance being estimated under the null hypothesis, likelihood rate statistic, log- and logit-transformation statistics based on both models generally perform well and are hence recommended. The approximate unconditional procedures based on the log-transformation statistic under Model I, Wald statistic with the variance being estimated under the null hypothesis, log- and logit-transformation statistics under Model II are recommended when sample size is small. In general, sample size formulae based on the Wald statistic with the variance being estimated under the null hypothesis, likelihood rate statistic and score statistic are recommended in practical applications. The applicability of the proposed methods is illustrated by a real-data example.


2006 ◽  
Vol 321-323 ◽  
pp. 1539-1542
Author(s):  
Wae Gyeong Shin ◽  
Soo Hong Lee ◽  
Young Sik Song

Reliability of automotive parts has been one of the most interesting fields in the automotive industry. Especially small DC motor was issued because of the increasing adoption for passengers’ safety and convenience. For several years, small DC motors have been studied and some problems of a life test method were found out. The field condition was not considered enough in the old life test method. It also needed a lot of test time. For precise life estimation and accelerated life test, new life test procedure was developed based on measured field condition. First, vibration condition on vehicle and latent force on fan motor shaft were measured and correlated with each other. Second, test condition was decided by obtained data. Finally, life of fan motors was estimated by new life test method in shorter test time.


Sign in / Sign up

Export Citation Format

Share Document