scholarly journals Spectral analysis of the photoconductivity for characterization of CdTe И CdZnTe detectors

2021 ◽  
Vol 2127 (1) ◽  
pp. 012041
Author(s):  
I M Gazizov ◽  
A A Smirnov

Abstract The results of the application of optical methods are considered: spectral analysis of photoconductivity in the range 400–1800 nm and field measurements of stationar photoconductivity to study the bulk and surface characteristics of CdTe and CdZnTe gamma-ray detectors. The studies of the photoresponse of the samples were carried out in different irradiation modes: modulated at a frequency of 25 Hz and a constant light flux. The measurements were carried out at room temperature on domestic and foreign materials of detector quality. Using the spectral photoconductivity method, the parameters of deep levels, which affect the detector properties, have been estimated in the studied materials. Based on the calculations of the field dependences of the photoconductivity, the volume and surface parameters of the capture and recombination of non-equilibrium carriers in the investigated detectors were determined. The results of calculating the transport characteristics of charge transfer by electrons μτe in detectors are compared with similar parameters measured using the traditional method of irradiating the detector with alpha particles. To measure the band gap in CdTe and CdZnTe at room temperature the method was modified for calculating ΔEg. The possibility of monitoring the Zn content in CdZnTe detectors using the spectral photoconductivity method is shown.

Author(s):  
Maria Concetta Maccarone ◽  
Giovanni La Rosa ◽  
Osvaldo Catalano ◽  
Salvo Giarrusso ◽  
Alberto Segreto ◽  
...  

AbstractUVscope is an instrument, based on a multi-pixel photon detector, developed to support experimental activities for high-energy astrophysics and cosmic ray research. The instrument, working in single photon counting mode, is designed to directly measure light flux in the wavelengths range 300-650 nm. The instrument can be used in a wide field of applications where the knowledge of the nocturnal environmental luminosity is required. Currently, one UVscope instrument is allocated onto the external structure of the ASTRI-Horn Cherenkov telescope devoted to the gamma-ray astronomy at very high energies. Being co-aligned with the ASTRI-Horn camera axis, UVscope can measure the diffuse emission of the night sky background simultaneously with the ASTRI-Horn camera, without any interference with the main telescope data taking procedures. UVscope is properly calibrated and it is used as an independent reference instrument for test and diagnostic of the novel ASTRI-Horn telescope.


2021 ◽  
Vol 12 (5) ◽  
pp. 645-649
Author(s):  
Yu Gu ◽  
Yuqing Qiao ◽  
Yusen Meng ◽  
Ming Yu ◽  
Bowu Zhang ◽  
...  

Herein, we report for the first time the synthesis of polypyrrole copolymers with good solvent-dispersibility under gamma-ray irradiation at room temperature in air.


Geophysics ◽  
1987 ◽  
Vol 52 (11) ◽  
pp. 1535-1546 ◽  
Author(s):  
Ping Sheng ◽  
Benjamin White ◽  
Balan Nair ◽  
Sandra Kerford

The spatial resolution of gamma‐ray logs is defined by the length 𝓁 of the gamma‐ray detector. To resolve thin beds whose thickness is less than 𝓁, it is generally desirable to deconvolve the data to reduce the averaging effect of the detector. However, inherent in the deconvolution operation is an amplification of high‐frequency noise, which can be a detriment to the intended goal of increased resolution. We propose a Bayesian statistical approach to gamma‐ray log deconvolution which is based on optimization of a probability function which takes into account the statistics of gamma‐ray log measurements as well as the empirical information derived from the data. Application of this method to simulated data and to field measurements shows that it is effective in suppressing high‐frequency noise encountered in the deconvolution of gamma‐ray logs. In particular, a comparison with the least‐squares deconvolution approach indicates that the incorporation of physical and statistical information in the Bayesian optimization process results in optimal filtering of the deconvolved results.


Transport ◽  
2016 ◽  
Vol 31 (2) ◽  
pp. 177-182 ◽  
Author(s):  
Mario De Luca ◽  
Francesco Abbondati ◽  
Thomas J. Yager ◽  
Gianluca Dell’Acqua

Surfaces of airport pavements are subject to contamination that can be very dangerous for the movement of aircraft particularly on the runway. A recurrent problem is represented by the deposits of vulcanized rubber of aircraft tires in the touchdown area during landings and lesser during take-offs. This causes a loss of grip that compromises the safety of aircraft movements in take-off and landing operations. This study deals with the surface characteristics decay phenomenon related to contamination from rubber deposits. The experiment was conducted by correlating the pavement surface characteristics, as detected by Grip Tester, to air traffic before and after de-rubberizing operation and two models were constructed for the assessment of functional capacity of the runway before and after the operations de-rubberizing.


Author(s):  
Thomas E. Shaw ◽  
Alfred P. Sattelberger ◽  
Titel Jurca

The true identity of the diethyl ether adduct of tungsten(IV) chloride, WCl4(Et2O) x , has been in doubt since 1985. Initially postulated as the bis-adduct, WCl4(Et2O)2, questions arose when elemental analyses were more in line with a mono-ether adduct, viz. WCl4(Et2O). It was proposed that this was due to the thermal instability of the bis-adduct. Here, we report the room-temperature X-ray crystal structure and Hirshfeld surface characteristics of trans-tetrachloridobis(diethyl ether)tungsten(IV), trans-WCl4(Et2O)2 or trans-[WCl4(C4H10O)2]. The compound crystallizes, with half of the molecule in the asymmetric unit, in the centrosymmetric space group P21/n. The W—O distance is 2.070 (2) Å, while the W—Cl distances are 2.3586 (10) and 2.3554 (10) Å.


2012 ◽  
Vol 8 (S291) ◽  
pp. 160-160
Author(s):  
Silvia Zane

AbstractSoft gamma-ray repeaters (SGRs) and anomalous X-ray pulsars (AXPs) are peculiar X-ray sources which are believed to be magnetars: ultra-magnetized neutron stars which emission is dominated by surface fields (often in excess of 1E14 G, i.e. well above the QED threshold).Spectral analysis is an important tool in magnetar astrophysics since it can provide key information on the emission mechanisms. The first attempts at modelling the persistent (i.e. outside bursts) soft X-ray (¡10 keV) spectra of AXPs proved that a model consisting of a blackbody (kT 0.3-0.6 keV) plus a power-law (photon index 2-4) could successfully reproduce the observed emission. Moreover, INTEGRAL observations have shown that, while in quiescence, magnetars emit substantial persistent radiation also at higher energies, up to a few hundreds of keV. However, a convincing physical interpretation of the various spectral components is still missing.In this talk I will focus on the interpretation of magnetar spectral properties during quiescence. I will summarise the present status of the art and the currents attempts to model the broadband persistent emission of magnetars (from IR to hard Xrays) within a self consistent, physical scenario.


2013 ◽  
Vol 28 (4) ◽  
pp. 415-421 ◽  
Author(s):  
Milic Pejovic

The gamma-ray irradiation sensitivity to radiation dose range from 0.5 Gy to 5 Gy and post-irradiation annealing at room and elevated temperatures have been studied for p-channel metal-oxide-semiconductor field effect transistors (also known as radiation sensitive field effect transistors or pMOS dosimeters) with gate oxide thicknesses of 400 nm and 1 mm. The gate biases during the irradiation were 0 and 5 V and 5 V during the annealing. The radiation and the post-irradiation sensitivity were followed by measuring the threshold voltage shift, which was determined by using transfer characteristics in saturation and reader circuit characteristics. The dependence of threshold voltage shift DVT on absorbed radiation dose D and annealing time was assessed. The results show that there is a linear dependence between DVT and D during irradiation, so that the sensitivity can be defined as DVT/D for the investigated dose interval. The annealing of irradiated metal-oxide-semiconductor field effect transistors at different temperatures ranging from room temperature up to 150?C was performed to monitor the dosimetric information loss. The results indicated that the dosimeters information is saved up to 600 hours at room temperature, whereas the annealing at 150?C leads to the complete loss of dosimetric information in the same period of time. The mechanisms responsible for the threshold voltage shift during the irradiation and the later annealing have been discussed also.


2021 ◽  
pp. 81-86
Author(s):  
Sharifa Utamuradova ◽  
Sultanposha Muzafarova ◽  
Abdulla Abdugafurov ◽  
Kakhramon Fayzullaev ◽  
Elmira Naurzalieva ◽  
...  

Based on CdTe and CdZnTe detectors a number of promising devices were created, which found their application in metallurgy, in solving the problems of customs control and control of nuclear materials, as well as matrix detectors created for the manufacture of medical devices and devices for space research. Detectors, created on the basis of polycrystalline semiconductor CdTe and CdZnTe films with a columnar structure on a molybdenum substrate with a thickness d = 30150 μm, had a specific resistance p > 10^5 10^8 W-cm. The energy resolution of the CdTe and CdZnTe detectors at room temperature reached ~ 5 keV on the 59.6 keV 241Am line.


Sign in / Sign up

Export Citation Format

Share Document