scholarly journals Modelling of Rigid Walled Enclosure Couple to a Flexible Wall using Matlab and Ansys APDL

2017 ◽  
Vol 914 ◽  
pp. 012038
Author(s):  
I Zaman ◽  
S A M Rozlan ◽  
N A Azmir ◽  
M Ismon ◽  
M A Madlan ◽  
...  
Keyword(s):  
2020 ◽  
Vol 15 (1) ◽  
pp. 37-44
Author(s):  
El Mehdi Echebba ◽  
Hasnae Boubel ◽  
Oumnia Elmrabet ◽  
Mohamed Rougui

Abstract In this paper, an evaluation was tried for the impact of structural design on structural response. Several situations are foreseen as the possibilities of changing the distribution of the structural elements (sails, columns, etc.), the width of the structure and the number of floors indicates the adapted type of bracing for a given structure by referring only to its Geometric dimensions. This was done by studying the effect of the technical design of the building on the natural frequency of the structure with the study of the influence of the distribution of the structural elements on the seismic response of the building, taking into account of the requirements of the Moroccan earthquake regulations 2000/2011 and using the ANSYS APDL and Robot Structural Analysis software.


2005 ◽  
Vol 158 (1-3) ◽  
pp. 34-44 ◽  
Author(s):  
R.J.M. Janssen ◽  
M.J. Verwijs ◽  
B. Scarlett
Keyword(s):  

Symmetry ◽  
2021 ◽  
Vol 13 (7) ◽  
pp. 1188
Author(s):  
Yiu-Yin Lee

This study addresses the frequency–amplitude relationship of a nonlinear symmetric panel absorber mounted on a flexible wall. In many structural–acoustic works, only one flexible panel is considered in their models with symmetric configuration. There are very limited research investigations that focus on two flexible panels coupled with a cavity, particularly for nonlinear structural–acoustic problems. In practice, panel absorbers with symmetric configurations are common and usually mounted on a flexible wall. Thus, it should not be assumed that the wall is rigid. This study is the first work employing the weighted residual elliptic integral method for solving this problem, which involves the nonlinear multi-mode governing equations of two flexible panels coupled with a cavity. The reason for adopting the proposed solution method is that fewer nonlinear algebraic equations are generated. The results obtained from the proposed method and finite element method agree reasonably well with each other. The effects of some parameters such as vibration amplitude, cavity depth and thickness ratio, etc. are also investigated.


2021 ◽  
Vol 1051 (1) ◽  
pp. 012039
Author(s):  
N H Mohd Azman ◽  
Z Yusof ◽  
Z A Rasid ◽  
M Z Hassan ◽  
H Yahaya ◽  
...  
Keyword(s):  

2021 ◽  
pp. 112697
Author(s):  
R. Lombroni ◽  
F. Giorgetti ◽  
G. Calabrò ◽  
P. Fanelli ◽  
G. Ramogida
Keyword(s):  

2002 ◽  
Vol 39 (3) ◽  
pp. 597-607 ◽  
Author(s):  
J K Kodikara ◽  
F Rahman ◽  
S L Barbour

Chemical compatibility tests using hydraulic conductivity testing with chemical permeants are normally undertaken to assess the integrity of compacted clayey liners used for waste containment. This paper highlights the fact that current routine methods of flexible wall and rigid wall testing techniques fail to represent the zero lateral strain boundary condition that is required to realistically represent the field situation. The test results indicate that flexible wall permeameters underestimate the likely increases in hydraulic conductivity due to chemicals, while the rigid wall permeameters can severely overestimate these effects. A new test technique, which incorporates the zero lateral strain condition in a simple manner, is presented. This technique involves the use of a rigid wall concept in a flexible wall permeameter. A split rigid mould is used to encase the soil specimen that is glued to the internal surfaces of the mould, to apply the zero lateral strain boundary condition. The new technique is shown to be suitable for both chemical compatibility and desiccation testing. The tests were undertaken with varying concentrations of saline water, methanol, and landfill leachate. The test results indicate that the new technique produces results that fall between the results obtained from flexible wall and rigid wall permeameters. It is argued that the new test technique provides a more rational approach for chemical compatibility testing than the current rigid wall and flexible wall techniques.Key words: soil, hydraulic conductivity, chemical compatibility, landfill, permeameter, boundary condition.


Author(s):  
Iarly Vanderlei da Silveira ◽  
Lineu José Pedroso ◽  
Giuliano Santa Marotta

abstract: This work aims to verify the influence of the foundation and the reservoir on the dynamic behavior of concrete gravity dams in terms of the natural frequencies, vibration modes for a free vibration analysis; and in terms of maximum displacements and maximum stresses at singular points of the structure for a seismic excitation. The dam-reservoir-foundation interaction was investigated through modal and transient analysis by the finite element method via ANSYS APDL software. For this study, we used a typical Brazilian dam profile and compatible data from a Brazilian earthquake for the seismic excitation. The results showed the influence of the reservoir and the foundation on the natural frequencies in the coupled system, as well as its repercussions on the response of the dam under seismic excitation.


2003 ◽  
Vol 40 (3) ◽  
pp. 559-574 ◽  
Author(s):  
Agus Setianto Samingan ◽  
Eng-Choon Leong ◽  
Harianto Rahardjo

This paper describes the development of a flexible wall permeameter apparatus for measuring the water and air coefficients of permeability of residual soils. Water and air coefficients of permeability were obtained for both the drying and wetting cycles for residual soils using the flexible wall permeameter. Volume changes of the soil specimens during unsaturated consolidation and during the water and air permeability measurements were also monitored. Factors that influence the measurements, such as hydraulic and pneumatic gradients and temperature fluctuations are described and discussed in this paper. The developed flexible wall permeameter was found to be capable of measuring water and air coefficients of permeability as low as 10–12 m/s.Key words: flexible wall permeameter, permeability, residual soils, unsaturated soils, matric suction, flow rate.


Sign in / Sign up

Export Citation Format

Share Document