scholarly journals X-ray imaging resolution of phosphor screens prepared with different grains size and shape of granular Lu2O3:Eu

2017 ◽  
Vol 931 ◽  
pp. 012032 ◽  
Author(s):  
I. E. Seferis ◽  
C. Michail ◽  
J. Zeler ◽  
I. Valais ◽  
G. Fountos ◽  
...  
Author(s):  
S.A. Pistrui-Maximean ◽  
N. Freud ◽  
J.M. Létang ◽  
A. Koch ◽  
B. Munier ◽  
...  

2015 ◽  
Vol 22 (2) ◽  
pp. 336-341 ◽  
Author(s):  
E. Nazaretski ◽  
K. Lauer ◽  
H. Yan ◽  
N. Bouet ◽  
J. Zhou ◽  
...  

Hard X-ray microscopy is a prominent tool suitable for nanoscale-resolution non-destructive imaging of various materials used in different areas of science and technology. With an ongoing effort to push the 2D/3D imaging resolution down to 10 nm in the hard X-ray regime, both the fabrication of nano-focusing optics and the stability of the microscope using those optics become extremely challenging. In this work a microscopy system designed and constructed to accommodate multilayer Laue lenses as nanofocusing optics is presented. The developed apparatus has been thoroughly characterized in terms of resolution and stability followed by imaging experiments at a synchrotron facility. Drift rates of ∼2 nm h−1accompanied by 13 nm × 33 nm imaging resolution at 11.8 keV are reported.


1997 ◽  
Vol 12 (5) ◽  
pp. 1385-1390 ◽  
Author(s):  
P. F. Carcia ◽  
M. Reilly ◽  
C. C. Torardi ◽  
M. K. Crawford ◽  
C. R. Miao ◽  
...  

In this paper we describe the preparation, microstructure, and x-ray excited luminescence of vapor-deposited CaWO4 films up to about 50 μm thick, comparing them to particulate CaWO4 phosphor screens, used in medical diagnostic imaging. Films that we e-beam evaporated on substrates heated at or above 500 °C were polycrystalline with the scheelite structure, while on unheated substrates, films were initially amorphous but became crystalline after annealing them in air above about 750 °C. Crystalline CaWO4 films irradiated with x-rays produced light emission peaked at 430 nm. The emission intensity depended on film thickness and grain size and was comparable to particulate CaWO4 phosphor screens. Because the vapor-deposited films also exhibited superior resolution, they are promising for diagnostic x-ray imaging.


Author(s):  
M.G. Baldini ◽  
S. Morinaga ◽  
D. Minasian ◽  
R. Feder ◽  
D. Sayre ◽  
...  

Contact X-ray imaging is presently developing as an important imaging technique in cell biology. Our recent studies on human platelets have demonstrated that the cytoskeleton of these cells contains photondense structures which can preferentially be imaged by soft X-ray imaging. Our present research has dealt with platelet activation, i.e., the complex phenomena which precede platelet appregation and are associated with profound changes in platelet cytoskeleton. Human platelets suspended in plasma were used. Whole cell mounts were fixed and dehydrated, then exposed to a stationary source of soft X-rays as previously described. Developed replicas and respective grids were studied by scanning electron microscopy (SEM).


Author(s):  
James F. Mancuso ◽  
William B. Maxwell ◽  
Russell E. Camp ◽  
Mark H. Ellisman

The imaging requirements for 1000 line CCD camera systems include resolution, sensitivity, and field of view. In electronic camera systems these characteristics are determined primarily by the performance of the electro-optic interface. This component converts the electron image into a light image which is ultimately received by a camera sensor.Light production in the interface occurs when high energy electrons strike a phosphor or scintillator. Resolution is limited by electron scattering and absorption. For a constant resolution, more energy deposition occurs in denser phosphors (Figure 1). In this respect, high density x-ray phosphors such as Gd2O2S are better than ZnS based cathode ray tube phosphors. Scintillating fiber optics can be used instead of a discrete phosphor layer. The resolution of scintillating fiber optics that are used in x-ray imaging exceed 20 1p/mm and can be made very large. An example of a digital TEM image using a scintillating fiber optic plate is shown in Figure 2.


Author(s):  
Ann LeFurgey ◽  
Peter Ingram ◽  
J.J. Blum ◽  
M.C. Carney ◽  
L.A. Hawkey ◽  
...  

Subcellular compartments commonly identified and analyzed by high resolution electron probe x-ray microanalysis (EPXMA) include mitochondria, cytoplasm and endoplasmic or sarcoplasmic reticulum. These organelles and cell regions are of primary importance in regulation of cell ionic homeostasis. Correlative structural-functional studies, based on the static probe method of EPXMA combined with biochemical and electrophysiological techniques, have focused on the role of these organelles, for example, in maintaining cell calcium homeostasis or in control of excitation-contraction coupling. New methods of real time quantitative x-ray imaging permit simultaneous examination of multiple cell compartments, especially those areas for which both membrane transport properties and element content are less well defined, e.g. nuclei including euchromatin and heterochromatin, lysosomes, mucous granules, storage vacuoles, microvilli. Investigations currently in progress have examined the role of Zn-containing polyphosphate vacuoles in the metabolism of Leishmania major, the distribution of Na, K, S and other elements during anoxia in kidney cell nuclel and lysosomes; the content and distribution of S and Ca in mucous granules of cystic fibrosis (CF) nasal epithelia; the uptake of cationic probes by mltochondria in cultured heart ceils; and the junctional sarcoplasmic retlculum (JSR) in frog skeletal muscle.


2000 ◽  
Vol 10 (PR9) ◽  
pp. Pr9-583-Pr9-588 ◽  
Author(s):  
W. A. Gooch ◽  
M. S. Burkins ◽  
G. Hauver ◽  
P. Netherwood ◽  
R. Benck
Keyword(s):  
X Ray ◽  

2020 ◽  
Author(s):  
Keyword(s):  
X Ray ◽  

Sign in / Sign up

Export Citation Format

Share Document