Vapor-deposited CaWO4 phosphor

1997 ◽  
Vol 12 (5) ◽  
pp. 1385-1390 ◽  
Author(s):  
P. F. Carcia ◽  
M. Reilly ◽  
C. C. Torardi ◽  
M. K. Crawford ◽  
C. R. Miao ◽  
...  

In this paper we describe the preparation, microstructure, and x-ray excited luminescence of vapor-deposited CaWO4 films up to about 50 μm thick, comparing them to particulate CaWO4 phosphor screens, used in medical diagnostic imaging. Films that we e-beam evaporated on substrates heated at or above 500 °C were polycrystalline with the scheelite structure, while on unheated substrates, films were initially amorphous but became crystalline after annealing them in air above about 750 °C. Crystalline CaWO4 films irradiated with x-rays produced light emission peaked at 430 nm. The emission intensity depended on film thickness and grain size and was comparable to particulate CaWO4 phosphor screens. Because the vapor-deposited films also exhibited superior resolution, they are promising for diagnostic x-ray imaging.

Author(s):  
M.G. Baldini ◽  
S. Morinaga ◽  
D. Minasian ◽  
R. Feder ◽  
D. Sayre ◽  
...  

Contact X-ray imaging is presently developing as an important imaging technique in cell biology. Our recent studies on human platelets have demonstrated that the cytoskeleton of these cells contains photondense structures which can preferentially be imaged by soft X-ray imaging. Our present research has dealt with platelet activation, i.e., the complex phenomena which precede platelet appregation and are associated with profound changes in platelet cytoskeleton. Human platelets suspended in plasma were used. Whole cell mounts were fixed and dehydrated, then exposed to a stationary source of soft X-rays as previously described. Developed replicas and respective grids were studied by scanning electron microscopy (SEM).


2013 ◽  
Vol 21 (2) ◽  
pp. 7-7
Author(s):  
Charles Lyman

Using X rays to produce magnified images of objects has been a goal for 150 years. Ever since Ernst Abbe declared in 1873 that light microscope resolution was limited by the wavelength of light, the search was on for a microscopy medium with a wavelength shorter than visible light (<500 nm). When Roentgen discovered X rays in 1895, it was thought that the new medium may have been found. Soon it was clear, however, that it was not easy to construct a physical lens for X rays because the rays penetrated all lens construction materials. X-ray “radiography images” of a few times magnification were possible but only as projection images, formed as X rays from millimeter-sized sources traveled in straight lines through the specimen to be captured on film. Unfortunately, even in the best cases, useful magnification was limited by the relatively large “point source” of X rays and the large grain size of X-ray film (both about 0.1–1.0 mm).


2021 ◽  
Author(s):  
Julius Muchui Thambura ◽  
Jeanette G.E du Plessis ◽  
Cheryl M E McCrindle ◽  
Tanita Cronje

Abstract Introduction Anecdotal evidence suggests that medical professionals in trauma units are requesting additional regional images using conventional x-ray systems, even after trauma patients have undergone full-body Lodox scans. Patients are then exposed to additional radiation, additional waiting times and an increased medical bill. This study aimed at investigating the extent to which Lodox systems were used in trauma units (n=28) in South Africa. Method In this descriptive cross-sectional study, the researcher invited one radiographer from the 28 hospitals in South Africa that use Lodox systems. Radiographers who were most experienced in using the Lodox system completed an online questionnaire. Results Twenty (71.43% n=20) out of twenty-eight radiographers responded. Most hospitals (90%, n=18) were referring patients for additional conventional x-ray images. Radiographers indicated that conventional x-rays were requested for the chest (27.80%, 10/36), the abdomen (16.67%, 6/36), the spine (13.89%, 5/36) and the extremities and skull (19.44%, 7/36). Additionally, radiographers reported using Lodox to perform procedures and examinations usually performed on conventional x-ray systems when conventional x-ray systems were not operational. Conclusion Currently, it is not clear if the use of conventional x-ray imaging following Lodox is necessary, but the results suggest that the practice is commonplace, with healthcare workers in most hospitals (90%, n=18) requesting additional x-ray imaging. The researcher thus recommends that an imaging protocol for Lodox imaging systems should be developed to guide the referral of the patients for further imaging.


Author(s):  
S.A. Pistrui-Maximean ◽  
N. Freud ◽  
J.M. Létang ◽  
A. Koch ◽  
B. Munier ◽  
...  

Author(s):  
Dipayan Das ◽  
KC Santosh ◽  
Umapada Pal

Abstract Since December 2019, the Coronavirus Disease (COVID-19) pandemic has caused world-wide turmoil in less than a couple of months, and the infection, caused by SARS-CoV-2, is spreading at an unprecedented rate. AI-driven tools are used to identify Coronavirus outbreaks as well as forecast their nature of spread, where imaging techniques are widely used, such as CT scans and chest X-rays (CXRs). In this paper, motivated by the fact that X-ray imaging systems are more prevalent and cheaper than CT scan systems, a deep learning-based Convolutional Neural Network (CNN) model, which we call Truncated Inception Net, is proposed to screen COVID-19 positive CXRs from other non-COVID and/or healthy cases. To validate our proposal, six different types of datasets were employed by taking the following CXRs: COVID-19 positive, Pneumonia positive, Tuberculosis positive, and healthy cases into account. The proposed model achieved an accuracy of 99.96% (AUC of 1.0) in classifying COVID- 19 positive cases from combined Pneumonia and healthy cases. Similarly, it achieved an accuracy of 99.92% (AUC of 0.99) in classifying COVID-19 positive cases from combined Pneumonia, Tuberculosis and healthy CXRs. To the best of our knowledge, as of now, the achieved results outperform the existing AI-driven tools for screening COVID-19 using CXRs.


2012 ◽  
Vol 2012 ◽  
pp. 1-13 ◽  
Author(s):  
A. Teymurazyan ◽  
G. Pang

A Monte Carlo simulation was used to study imaging and dosimetric characteristics of a novel design of megavoltage (MV) X-ray detectors for radiotherapy applications. The new design uses Cerenkov effect to convert X-ray energy absorbed in optical fibres into light for MV X-ray imaging. The proposed detector consists of a matrix of optical fibres aligned with the incident X rays and coupled to an active matrix flat-panel imager (AMFPI) for image readout. Properties, such as modulation transfer function, detection quantum efficiency (DQE), and energy response of the detector, were investigated. It has been shown that the proposed detector can have a zero-frequency DQE more than an order of magnitude higher than that of current electronic portal imaging device (EPID) systems and yet a spatial resolution comparable to that of video-based EPIDs. The proposed detector is also less sensitive to scattered X rays from patients than current EPIDs.


2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Pasquale Delogu ◽  
Vittorio Di Trapani ◽  
Luca Brombal ◽  
Giovanni Mettivier ◽  
Angelo Taibi ◽  
...  

Abstract The limits of mammography have led to an increasing interest on possible alternatives such as the breast Computed Tomography (bCT). The common goal of all X-ray imaging techniques is to achieve the optimal contrast resolution, measured through the Contrast to Noise Ratio (CNR), while minimizing the radiological risks, quantified by the dose. Both dose and CNR depend on the energy and the intensity of the X-rays employed for the specific imaging technique. Some attempts to determine an optimal energy for bCT have suggested the range 22 keV–34 keV, some others instead suggested the range 50 keV–60 keV depending on the parameters considered in the study. Recent experimental works, based on the use of monochromatic radiation and breast specimens, show that energies around 32 keV give better image quality respect to setups based on higher energies. In this paper we report a systematic study aiming at defining the range of energies that maximizes the CNR at fixed dose in bCT. The study evaluates several compositions and diameters of the breast and includes various reconstruction algorithms as well as different dose levels. The results show that a good compromise between CNR and dose is obtained using energies around 28 keV.


1986 ◽  
Vol 71 ◽  
Author(s):  
R. V. Joshi ◽  
D. A. Smith

AbstractThe characteristics of Selective LPCVD tungsten films produced by silicon reduction of tungsten hexafluoride are presented. The tungsten films deposited using Si(100), Si(111) and polysilicon undoped and doped substrates are analyzed by X-RAY, TEM, RBS, AES, SIMS and SEM. The as deposited bcc tungsten films are polycrystalline with a grain size 80 - 100Å. The effect of annealing temperature and time on the crystal structure of films was studied. Tungsten reacts to form tungsten silicide at 600°C. The silicide grain size is of the order of 100 - 200Å at 600°C and increases gradually to 400 - 500Å at 1000°C. The oxygen impurities in the film retard the silicide formation further at 1000°C. Silicon from the substrate out-diffuses to the film surface and reacts with the presence of oxygen impurities in the annealing ambient to form Si-O at 1000°C. As deposited film resistivities of 130-140 micro-ohm-cm are achieved reproducibly and reach 60-70 micro-ohm-cm after 1000°C annealing in nitrogen or argon ambient. The impurities H, C, O and F are found in the as deposited films.


2017 ◽  
Vol 33 (5) ◽  
pp. 721-728 ◽  
Author(s):  
Zephania R. Odek ◽  
Bhagwati Prakash ◽  
Terry J. Siebenmorgen

Abstract. X-ray imaging is a viable method of fissure detection in rough rice kernels owing to the ability of X-rays to penetrate hulls, thus allowing visualization of internal rice kernel structure. Traditional methods of fissure detection are only applicable for brown and milled rice, and therefore cannot be used to study fissures developed during rough rice drying. In this study, the fissure detection capability of an X-ray system was evaluated and the relationship between head rice yield (HRY), as measured through laboratory milling, and the percentage of fissured rough rice kernels was determined. Long-grain rice lots of various cultivars were dried using heated air at 60°C, 10% relative humidity (RH) for five drying durations to produce different degrees of fissuring, and then milled to determine HRY. A strong linear correlation (R2 = 0.95) between HRY and the percentage of fissured rough rice kernels after drying was determined. This correlation confirms the substantial impact that kernel fissures have on milling yields. Overall, these findings show the effectiveness of X-ray imaging in rough rice fissure detection, which could allow for drying research that may provide a better understanding of kernel fissuring kinetics. Keywords: Fissures, Grainscope, Head rice yield, Rice drying, X-ray imaging.