scholarly journals Determination of Optimal Air Change Rate for Cooling the Bedrooms of Residential Buildings in Guangzhou

2021 ◽  
Vol 719 (2) ◽  
pp. 022048
Author(s):  
Cuicui Qin ◽  
Yufeng Zhang ◽  
Lihua Zhao
Energies ◽  
2020 ◽  
Vol 14 (1) ◽  
pp. 127
Author(s):  
Artur Miszczuk ◽  
Dariusz Heim

Airtightness is nowadays one of the physical parameters which determine overall building energy performance. In a wide range of states, the upper limit for air change rate at a Pa (na), air permeability rate at a Pa (qa), or specific leakage rate at a Pa (wa) is determined by the formal regulations. It should be highlighted that airtightness requirements are mainly the same around the world, disregarding any site and climatic conditions. The main goal of the presented work was to reveal the effect of individual location and surrounding infiltration rate and heat demand. The analyses were done using numerical techniques and computational models of the three buildings developed and calibrated based on the blower door test results. The compared buildings characterize by a similar geometry but differ in the air change rate at 50 Pa (n50). Analyses done for different locations and levels of sheltering by surrounding elements allow the determination of the real effect of local conditions. The obtained differences in energy demand between two locations from the same climatic zone were from 70% to 90%, depending on the airtightness of the buildings. Considering different sheltered conditions, the differences for the same location can be even 200%. The obtained results allowed for the formulation of the general conclusion that building location and level of exposure could be considered in future airtightness regulations.


Energies ◽  
2019 ◽  
Vol 12 (17) ◽  
pp. 3360 ◽  
Author(s):  
Carolina Aparicio-Fernández ◽  
José-Luis Vivancos ◽  
Paula Cosar-Jorda ◽  
Richard A. Buswell

In this paper, the building energy performance modelling tools TRNSYS (TRaNsient SYstem Simulation program) and TRNFlow (TRaNsient Flow) have been used to obtain the energy demand of a domestic building that includes the air infiltration rate and the effect of natural ventilation by using window operation data. An initial model has been fitted to monitoring data from the case study, building over a period when there were no heat gains in the building in order to obtain the building infiltration air change rate. After this calibration, a constant air-change rate model was established alongside two further models developed in the calibration process. Air change rate has been explored in order to determine air infiltrations caused by natural ventilation due to windows being opened. These results were compared to estimates gained through a previously published method and were found to be in good agreement. The main conclusion from the work was that the modelling ventilation rate in naturally ventilated residential buildings using TRNSYS and TRNSFlow can improve the simulation-based energy assessment.


Buildings ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 259
Author(s):  
Ádám László Katona ◽  
István Ervin Háber ◽  
István Kistelegdi

A huge portion of energy consumption in buildings comes from heating, ventilation, and air conditioning. Numerous previous works assessed the potential of natural ventilation compared to mechanical ventilation and proved their justification on the field. Nevertheless, it is a major difficulty to collect enough information from the literature to make decisions between different natural ventilation solutions with a given situation and boundary conditions. The current study tests the passive air conduction system (PACS) variations in the design phase of a medium-sized new winery’s cellar and production hall in Villány, Hungary. A computational fluid dynamics simulation based comparative analysis enabled to determine the differences in updraft (UD) and downdraught (DD) PACS, whereby the latter was found to be more efficient. While the DD PACS performed an air change range of 1.02 h−1 to 5.98 h−1, the UD PACS delivered −0.25 h−1 to 12.82 h−1 air change rate. The ventilation performance of the DD version possessed lower amplitudes, but the distribution was more balanced under different wind incident angles, thus this version was chosen for construction. It could be concluded that the DD PACS provides a more general applicability for natural ventilation in moderate climates and in small to medium scale industry hall domains with one in- and one outlet.


2014 ◽  
Vol 635-637 ◽  
pp. 60-64
Author(s):  
Daria Vladimirovna Petrosova ◽  
Dmitri Vadimovich Petrosov ◽  
Natalia Mikhailovna Kuzmenko

Now in Russia construction of buildings with framework use from a metalwork which show itself as universal, strong, easy and fast-built is actively conducted. There are offers and initial experience of application of easy steel protecting designs with an effective heater in multystoried frame residential buildings, but without sufficient theoretical and experimental justification.In this regard, the question of determination of the heatphysical properties, in particular the specified resistance to a heat transfer, is actual.Results of laboratory researches of the specified resistance are presented to a heat transfer of an easy protecting design in article.


Measurement ◽  
2018 ◽  
Vol 124 ◽  
pp. 539-548 ◽  
Author(s):  
Marcel Macarulla ◽  
Miquel Casals ◽  
Núria Forcada ◽  
Marta Gangolells ◽  
Alberto Giretti

Author(s):  
Iveta Bullová ◽  
Peter Kapalo ◽  
Dušan Katunský

Air change rate is an important parameter for quantification of ventilation heat losses and also affects the indoor climate of buildings. Indoor air quality is significantly associated with ventilation. If air change isn't sufficient, trapped allergens, pollutants and irritants can degrade the indoor air quality and affect the well-being of a building's occupants. Many studies on ventilation and health have concluded that lower air change rates can have a negative effect on people’s health and low ventilation may result in an increase in allergic diseases. Quantification of air change rate is complicated, since it is affected by a number of parameters, of which the one of the most variable is the air-wind flow. This study aims to determination and comparison of values of the air change rate in two methods - by quantifying of aerodynamic coefficient Cp = Cpe - Cpi – so called aerodynamic quantification of the building and the methodology based on experimental measurements of carbon dioxide in the selected reference room in apartment building.


1997 ◽  
Vol 46 (4) ◽  
pp. 251-257 ◽  
Author(s):  
Masakazu HASEGAWA ◽  
Yuzuru KURABAYASHI ◽  
Toshinori ISHII ◽  
Kazuya YOSHIDA ◽  
Nobukazu UEBAYASHI ◽  
...  

Energies ◽  
2020 ◽  
Vol 13 (21) ◽  
pp. 5529
Author(s):  
Fabian Niedermeyer ◽  
Martin Braun

Declining costs for high-performance batteries are leading to a global increased use of storage systems in residential buildings. Especially in conjunction with reduced photovoltaic (PV) feed-in tariffs, a large market has been developed for PV battery systems to increase self-sufficiency. They differ in the type of coupling between PV and battery, the nominal capacities of their components, and their degree of integration. High system performance is particularly important to achieve profitability for the operator. This paper presents and evaluates methods for a uniform determination of PV battery system performance. Already the requirement analysis reveals that a performance comparison of PV battery systems must cover the efficiency and effectiveness during system operation. A method based on a derivation of key performance indicators (KPIs) for these two criteria through an application test is proposed. It is evaluated by comparison to other methods, such as the System Performance Index (SPI) and aggregation of conversion and storage efficiency. These methods are applied with five systems in a laboratory test bench to identify their advantages and drawbacks. Here, a particular focus is on compliance with the initially formulated requirements in terms of both test procedures and KPI derivations. Analysis revealed that the proposed method addresses these requirements well, and is beneficial in terms of result comprehensibility and KPI validity.


Sign in / Sign up

Export Citation Format

Share Document