scholarly journals Modeling the Correlation Relationship of Aqueous Battery Parameters Based on Regression Analysis

2021 ◽  
Vol 898 (1) ◽  
pp. 012020
Author(s):  
Liwen Xiang ◽  
Jie Jin ◽  
Jinghui Zhang ◽  
Changjiang Ma ◽  
Bingnan Xiang ◽  
...  

Abstract This study is a research on the new Aqueous battery. Based on the experimental data, the author selects the charge and discharge capacity, voltage and current of the battery during the charging and discharging process, establishing the correlation model between the parameters of the battery through regression analysis and other methods, and concluding the methods to optimise the performance and power supply capacity of the battery, which can explore a new high-efficiency battery that can replace the ordinary battery and provide new ideas and methods for the development of battery business.

2012 ◽  
Vol 605-607 ◽  
pp. 433-437
Author(s):  
Hong Yang ◽  
Wen Qi Huang ◽  
Zhen Fei Wang ◽  
Long Guang Chen ◽  
Yao Yin

In order to improve the efficiency of solar module, we have designed the Fresnel lens concentrated system and charging system, their schematic diagrams are depicted detailed in this paper. The experimental data show that adding Fresnel lens parts can improve the solar panels' power from 130% to 200% and incident angle can affect solar panels' voltage current characteristic deeply. All of these results can give some support to design the tracking system.


2012 ◽  
Vol 476-478 ◽  
pp. 2496-2500
Author(s):  
Yong Chen ◽  
Wei Na Li ◽  
Xi Jun Wang ◽  
Shi Jie Shen

With Larch timber as the experimental subject, according to the visual grading-related rules in ASTM D245, four-point bending edge-wise in ASTM D4716-05 and axial strength in tension, the regression analysis is conducted; investigate the correlation relationship of Kus, E4s and σw. The result demonstrates that the combination of visual grading, density and four-point bending MOE, the predict of the parallel tensile strength will be more exactly whose correlation coefficient is 0.750.


Author(s):  
Zhengwang Xu ◽  
Wei Mei ◽  
Jiaqi Yu ◽  
Jiarui Zhang ◽  
Yuchun Yi ◽  
...  

As being restricted by factors such as cost, efficiency and size, the development of high-power solar LED street light controller is faced with plenty of difficulties. In case that a structure of two independent DC/DC is applied as the main circuit, it has to face problems such as large size and high cost; in case of applying the bidirectional BUCK/BOOST circuit, it requires change-over switches to control the solar panel and LED light. As being restricted by withstanding voltage, on-resistance and cost, a PMOS device cannot be used as the change-over switch of solar panel and LED light. However, when being used as a change-over switch, an NMOS device must apply the low-side mode under which the negative ends of the mentioned three parts are cut off. In the condition of applying the low-side mode, a differential circuit must be used to detect the voltage of the solar panel. Furthermore, in order to make sure batteries can still be regularly charged after wearing out in daylight, the controller must be supplied with power through a dual power supply circuit that can obtain power from both the solar panel and the battery. The demander has a requirement on extremely low standby power consumption of the product, and thus it is necessary to minimize the circuit that is live while working in standby mode. Methods: The bidirectional BUCK/BOOST circuit structure is applied to the main circuit to realize a higher change-over efficiency while giving considerations to both cost and size. The NMOS device, model IRFB4410ZPBF, with a price of about three yuan, is used as the switching device, and the low-side mode is applied, that is the switches inserted in between negative end of the solar panel or LED light and that of the DC/DC circuit. The low-cost rail-to-rail operational amplifier LM358 is used to form a differential amplification circuit for detecting the voltage of the solar panel. A XL1509-12E1 chip that only costs 0.88 yuan/pc is selected as the main change-over chip for the power supply, which has realized the highly-efficient and low-cost change-over of the power supply. A dual power supply circuit and a step-down protective circuit are designed for the XL1509-12E1 change-over chip. By comparing solar panel voltage with battery voltage, the solar panel booting circuit is realized. Only when solar panel voltage is higher than battery voltage, does the system program start to power it up for running, so that the outage of most of the circuits of the system under standby mode does not consume energy. Furthermore, the solar panel voltage detecting circuit, the solar panel booting circuit and several return difference functions are corrected during system debugging. Results: The circuit board of the entire controller features small size, low cost and high efficiency. It measures about 100*62*18mm in size, costs about 60 yuan, and the charge/discharge change-over efficiency reaches up to over 95%. The controller has many functions: it is capable of operating within a large scope, in which, solar panel voltage is subject to 15~50V, LED light voltage is subject to 15~60V, battery voltage is subject to 10~35V and battery-end charge/discharge current is 10A; it is capable of adapting to monocrystalline silicon/multicrystalline silicon/thin-film and many other kinds of solar panels, as well as lithium/lead-acid and many other kinds of batteries; it is capable of detecting the conversion of day and night, automatically controlling charging and discharging and automatically making adaptive adjustment according to seasonal variations; the current to be consumed during standby will be maintained below 3mA, and thus the power consumption is extremely low. Conclusion: By selecting the bidirectional BUCK/BOOST circuit structure, applying low-side mode for switching of solar panel and LED light, using a differential circuit to detect solar panel voltage, using a low-cost DC/DC chip to realize power supply change-over, designing a dual power supply circuit, introducing solar panel booting circuit and other hardware design, as well as MPPT algorithm, state recognition and control, return difference control and other software design, a solar LED street light control product featuring small size, low cost, high efficiency and multiple functions is successfully developed.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Rongxin Wang ◽  
Jing Wang ◽  
Shuiqing Hu

Abstract Background The etiology of reflux esophagitis (RE) is multi-factorial. This study analyzed the relationship of depression, anxiety, lifestyle and eating habits with RE and its severity and further explored the impact of anxiety and depression on patients’ symptoms and quality of life. Methods From September 2016 to February 2018, a total of 689 subjects at Xuanwu Hospital Capital Medical University participated in this survey. They were divided into the RE group (patients diagnosed with RE on gastroscopy, n = 361) and the control group (healthy individuals without heartburn, regurgitation and other gastrointestinal symptoms, n = 328). The survey included general demographic information, lifestyle habits, eating habits, comorbidities, current medications, the gastroesophageal reflux disease (GERD) questionnaire (GerdQ), the Patient Health Questionnaire-9 depression scale and the General Anxiety Disorder-7 anxiety scale. Results The mean age and sex ratio of the two groups were similar. Multivariate logistic regression analysis identified the following factors as related to the onset of RE (p < 0.05): low education level; drinking strong tea; preferences for sweets, noodles and acidic foods; sleeping on a low pillow; overeating; a short interval between dinner and sleep; anxiety; depression; constipation; history of hypertension; and use of oral calcium channel blockers. Ordinal logistic regression analysis revealed a positive correlation between sleeping on a low pillow and RE severity (p = 0.025). Depression had a positive correlation with the severity of symptoms (rs = 0.375, p < 0.001) and patients’ quality of life (rs = 0.306, p < 0.001), whereas anxiety showed no such association. Conclusions Many lifestyle factors and eating habits were correlated with the onset of RE. Notably, sleeping on a low pillow was positively correlated with RE severity, and depression was positively related to the severity of symptoms and patients’ quality of life.


2013 ◽  
Vol 834-836 ◽  
pp. 1221-1224
Author(s):  
Hong Zhuan Cai ◽  
Li Bai

Switching power supply is an important field of application of power electronic technology, the high frequency switching DC power supply with high efficiency, small size, light weight and other advantages obtain the widespread application. The application of synchronous rectifier technology, photoelectric coupling isolation technology and the active clamp forward converter design high frequency switching power supply with 16~40V DC input and 5V/100W DC output . its operational principle is analyzed, and using LM5026 control chip describes design method of switching power supply.


2007 ◽  
Vol 23 ◽  
pp. 119-122
Author(s):  
Cristina Teișanu ◽  
Stefan Gheorghe ◽  
Ion Ciupitu

The most important features of the self-lubricating bearings are the antifriction properties such as friction coefficient and wear resistence and some mechanical properties such as hardness, tensile strength and radial crushing strength. In order to improve these properties new antifriction materials based on iron-copper powders with several additional components (tin, lead and molybdenum disulphide) have been developed by PM techniques. To find the optimal relationship between chemical compositions, antifriction and mechanical properties, in this paper a mathematical model of the sintering process is developed, which highlighted the accordance of the model with data by regression analysis. For the statistical processing of the experimental data the VH5 hardness values of the studied materials were considered. The development of mathematical model includes the enunciation of the model, the establishment of the performance function (optimization) and the establishment of the model equations and verifying. The accordance of the model with experimental data has been highlighted by regression analysis


2013 ◽  
Vol 135 (3) ◽  
Author(s):  
Yanshuang Wang ◽  
Pu Li ◽  
JiaWei Cao ◽  
Yan Li

The elastohydrodynamic (EHD) traction coefficients of a lubricating grease LGLT2 were tested at various loads and rolling speeds on a self-made test rig. Traction coefficient versus slide-to-roll ratio curves were generated. Formulae which relate traction coefficient with normal load and rolling speed are put forth. The coefficients of the formulae may be computed by regression analysis of the experimental data. The results show that the calculated traction coefficients agree well with the experimental observation. The critical normal load exists when the traction coefficients change with the normal loads.


Sign in / Sign up

Export Citation Format

Share Document