THE HSE/NPL PHASE-CONTRAST TEST SLIDE

Keyword(s):  
Author(s):  
Mitsuo Ohtsuki ◽  
Michael Sogard

Structural investigations of biological macromolecules commonly employ CTEM with negative staining techniques. Difficulties in valid image interpretation arise, however, due to problems such as variability in thickness and degree of penetration of the staining agent, noise from the supporting film, and artifacts from defocus phase contrast effects. In order to determine the effects of these variables on biological structure, as seen by the electron microscope, negative stained macromolecules of high density lipoprotein-3 (HDL3) from human serum were analyzed with both CTEM and STEM, and results were then compared with CTEM micrographs of freeze-etched HDL3. In addition, we altered the structure of this molecule by digesting away its phospholipid component with phospholipase A2 and look for consistent changes in structure.


Author(s):  
S. Golladay

The theory of multiple scattering has been worked out by Groves and comparisons have been made between predicted and observed signals for thick specimens observed in a STEM under conditions where phase contrast effects are unimportant. Independent measurements of the collection efficiencies of the two STEM detectors, calculations of the ratio σe/σi = R, where σe, σi are the total cross sections for elastic and inelastic scattering respectively, and a model of the unknown mass distribution are needed for these comparisons. In this paper an extension of this work will be described which allows the determination of the required efficiencies, R, and the unknown mass distribution from the data without additional measurements or models. Essential to the analysis is the fact that in a STEM two or more signal measurements can be made simultaneously at each image point.


Author(s):  
J.M. Cowley

The problem of "understandinq" electron microscope imaqes becomes more acute as the resolution is improved. The naive interpretation of an imaqe as representinq the projection of an atom density becomes less and less appropriate. We are increasinqly forced to face the complexities of coherent imaqinq of what are essentially phase objects. Most electron microscopists are now aware that, for very thin weakly scatterinq objects such as thin unstained bioloqical specimens, hiqh resolution imaqes are best obtained near the optimum defocus, as prescribed by Scherzer, where the phase contrast imaqe qives a qood representation of the projected potential, apart from a lack of information on the lower spatial frequencies. But phase contrast imaqinq is never simple except in idealized limitinq cases.


Author(s):  
Y. Harada ◽  
T. Goto ◽  
H. Koike ◽  
T. Someya

Since phase contrasts of STEM images, that is, Fresnel diffraction fringes or lattice images, manifest themselves in field emission scanning microscopy, the mechanism for image formation in the STEM mode has been investigated and compared with that in CTEM mode, resulting in the theory of reciprocity. It reveals that contrast in STEM images exhibits the same properties as contrast in CTEM images. However, it appears that the validity of the reciprocity theory, especially on the details of phase contrast, has not yet been fully proven by the experiments. In this work, we shall investigate the phase contrast images obtained in both the STEM and CTEM modes of a field emission microscope (100kV), and evaluate the validity of the reciprocity theory by comparing the experimental results.


Author(s):  
Juan Mora-Galindo ◽  
Jorge Arauz-Contreras

The zinc iodide-osmium tetroxide (ZIO) technique is presently employed to study both, neural and non neural tissues. Precipitates depends on cell types and possibly cell metabol ism as well.Guinea pig cecal mucosa, already known to be composed of epithelium with cells at different maturation stages and lamina propria which i s formed by morphologically and functionally heterogeneous cell population, was studied to determine the pat tern of ZIO impregnation. For this, adult Guinea pg cecal mucosa was fixed with buffered 1.2 5% g 1 utara 1 dehyde before incubation with ZIO for 16 hours, a t 4°C in the dark. Further steps involved a quick sample dehydration in graded ethanols, embedding in Epon 812 and sectioning to observe the unstained material under a phase contrast light microscope (LM) and a transmission electron microscope (TEM).


Author(s):  
N.V. Belov ◽  
U.I. Papiashwili ◽  
B.E. Yudovich

It has been almost universally adopted that dissolution of solids proceeds with development of uniform, continuous frontiers of reaction.However this point of view is doubtful / 1 /. E.g. we have proved the active role of the block (grain) boundaries in the main phases of cement, these boundaries being the areas of hydrate phases' nucleation / 2 /. It has brought to the supposition that the dissolution frontier of cement particles in water is discrete. It seems also probable that the dissolution proceeds through the channels, which serve both for the liquid phase movement and for the drainage of the incongruant solution products. These channels can be appeared along the block boundaries.In order to demonsrate it, we have offered the method of phase-contrast impregnation of the hardened cement paste with the solution of methyl metacrylahe and benzoyl peroxide. The viscosity of this solution is equal to that of water.


Author(s):  
William Krakow ◽  
Benjamin Siegel

Unwin has used a metallized non-conducting thread in the back focal plane of the objective lens that stops out a portion of the unscattered beam, takes on a localized positive charge and thus produces an additional phase shift to give a different transfer function of the lens. Under the particular conditions Unwin used, the phase contrast image was shifted to bright phase contrast for optimum focus.We have investigated the characteristics of this type of electrostatic phase plate, both analytically and experimentally, as functions of the magnitude of charge and defocus. Phase plates have been constructed by using Wollaston wire to mount 0.25μ diameter platinum wires across apertures ranging from 50 to 200μ diameter and vapor depositing SiO and gold on the mounted wires to give them the desired charging characteristics. The net charge was varied by adjusting only the bias on the Wehnelt shield of the gun, and hence the beam currents and effective size of the source.


Author(s):  
Yu Liu

The image obtained in a transmission electron microscope is the two-dimensional projection of a three-dimensional (3D) object. The 3D reconstruction of the object can be calculated from a series of projections by back-projection, but this algorithm assumes that the image is linearly related to a line integral of the object function. However, there are two kinds of contrast in electron microscopy, scattering and phase contrast, of which only the latter is linear with the optical density (OD) in the micrograph. Therefore the OD can be used as a measure of the projection only for thin specimens where phase contrast dominates the image. For thick specimens, where scattering contrast predominates, an exponential absorption law holds, and a logarithm of OD must be used. However, for large thicknesses, the simple exponential law might break down due to multiple and inelastic scattering.


Author(s):  
E.M. Waddell ◽  
J.N. Chapman ◽  
R.P. Ferrier

Dekkers and de Lang (1977) have discussed a practical method of realising differential phase contrast in a STEM. The method involves taking the difference signal from two semi-circular detectors placed symmetrically about the optic axis and subtending the same angle (2α) at the specimen as that of the cone of illumination. Such a system, or an obvious generalisation of it, namely a quadrant detector, has the characteristic of responding to the gradient of the phase of the specimen transmittance. In this paper we shall compare the performance of this type of system with that of a first moment detector (Waddell et al.1977).For a first moment detector the response function R(k) is of the form R(k) = ck where c is a constant, k is a position vector in the detector plane and the vector nature of R(k)indicates that two signals are produced. This type of system would produce an image signal given bywhere the specimen transmittance is given by a (r) exp (iϕ (r), r is a position vector in object space, ro the position of the probe, ⊛ represents a convolution integral and it has been assumed that we have a coherent probe, with a complex disturbance of the form b(r-ro) exp (iζ (r-ro)). Thus the image signal for a pure phase object imaged in a STEM using a first moment detector is b2 ⊛ ▽ø. Note that this puts no restrictions on the magnitude of the variation of the phase function, but does assume an infinite detector.


Author(s):  
Joachim Frank

Compared with images of negatively stained single particle specimens, those obtained by cryo-electron microscopy have the following new features: (a) higher “signal” variability due to a higher variability of particle orientation; (b) reduced signal/noise ratio (S/N); (c) virtual absence of low-spatial-frequency information related to elastic scattering, due to the properties of the phase contrast transfer function (PCTF); and (d) reduced resolution due to the efforts of the microscopist to boost the PCTF at low spatial frequencies, in his attempt to obtain recognizable particle images.


Sign in / Sign up

Export Citation Format

Share Document