scholarly journals QTc interval prolongation and life-threatening arrhythmias during hospitalization in patients with COVID-19. Results from a multi-center prospective registry

Author(s):  
Francesco Santoro ◽  
Francesco Monitillo ◽  
Pasquale Raimondo ◽  
Agostino Lopizzo ◽  
Gaetano Brindicci ◽  
...  

Abstract Background Prolonged QTc interval and life-threatening arrhythmias (LTA) are potential drug induced complications previously reported with antimalarial, antivirals and antibiotics. Objectives To evaluate prevalence and predictors of QTc interval prolongation and incidence of LTA during hospitalization for COVID-19 among patients with normal admission QTc. Methods 110 consecutive patients were enrolled in a multicenter international registry. 12-lead ECG was performed at admission, after 7 and 14 days; QTc values were analyzed. Results Fifteen (14%) patients developed a prolonged-QTc (pQT) after 7 days (mean QTc increase 66±20msec, +16%, p<0.001); these patients were older, had higher basal heart rates, higher rates of paroxysmal atrial fibrillation, lower platelet count. QTc increase was inversely proportional to baseline QTc levels and leukocyte count and directly to basal heart rates(p<0.01).At multivariate stepwise analysis including age, male gender, paroxysmal atrial fibrillation, basal QTc values, basal heart rate and dual antiviral therapy, age(OR 1.06, 95% C.I. 1.00-1.13, p<0.05), basal heart rate(OR 1.07, 95% C.I. 1.02-1.13, p<0.01) and dual antiviral therapy(OR 12.46, 95% C.I. 2.09-74.20, p<0.1) were independent predictors of QT-prolongation.Incidence of LTA during hospitalization was 3.6%. One patient experienced cardiac arrest and three non-sustained ventricular tachycardia. LTAs were recorded after a median of 9 days from hospitalization and were associated with 50% of mortality rate. Conclusions After 7 days of hospitalization, 14% of patients with Covid-19 developed pQTc; age, basal heart rate and dual antiviral therapy were found as independent predictor of pQTc. Life threatening arrhythmias have an incidence of 3.6% and were associated with poor outcome.

2019 ◽  
Vol 37 (15_suppl) ◽  
pp. 3033-3033
Author(s):  
Anan Abdelmoti Abu Rmilah ◽  
Grace Lin ◽  
Joerg Herrmann

3033 Background: QTc interval prolongation can lead to life-threatening complications such as torsade de pointes (TdP), ventricular tachycardia (VT), and sudden cardiac death (SCD). It can occur with various tyrosine kinase inhibitors (TKIs) but comparative analyses on the incidence and complication rates are scarce. We thus conducted a comprehensive analysis of TKI use and QTc prolongation in clinical practice. Methods: We retrospectively reviewed the electronic medical records of all cancer patients who were treated with TKI between 01/2005 and 12/2018 at our institution. QTc prolongation was defined as a QTc ≥ 450 ms or 460 ms among male or female patients, respectively. For each type of TKIs, we determined the administration rate and incidence of QTc interval prolongation. We also studied the frequency of QTc prolongation ≥ 500 ms, rate of increase of the QTc interval by ≥ 60 ms, and the development of complications (VT, TdP and SCD). Results: In the present study, we analyzed the data of 685 cancer patients (431 male and 254 female), including 299 patients with RCC, 188 with chronic leukemia, 55 with acute leukemia, 65 with thyroid cancer, 48 with lung cancer and 39 with GIST. These patients received 902 TKI administrations and QTc prolongation was reported in 1/3 of these (289 administrations). The highest frequency was seen with imatinib, nilotinib and dasatinib (30, 40 and 50%). Among cases of QTc prolongation, a QTc interval ≥ 500 ms was documented in 53 (18.3%) and QTc progression ≥ 60 ms in 72 (25%). Complications were found in 14 cases (5%) including VT in 9, TdP in 2 and SCD in 3 administrations. Conclusions: The current findings suggest that TKI therapy leads to QTc prolongation in 1/3 of patients on average and most commonly with the Bcr-Abl TKIs, imatinib, nilotinib and dasatinib. While SCD is rare (1%) it can still evolve and in 5% of all QTc prolongations with TKIs are potentially life-threatening. These data support recommendations for serial ECGs in cancer patients undergoing TKI therapy. [Table: see text]


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
J.P Sousa ◽  
L Puga ◽  
J Ribeiro ◽  
J Lopes ◽  
C Saleiro ◽  
...  

Abstract Background Currently available pharmacological options for rhythm control in atrial fibrillation (AF) are overshadowed by suboptimal efficacy and both frequent and potentially severe adverse events. Recent studies have added evidence to the hypothesis that ranolazine might exert antiarrhythmic effects, particularly in atrial tachyarrhythmias. Purpose To perform a systematic review with meta-analysis in order to ascertain the potential role of ranolazine in the management of AF. Methods We systematically searched MEDLINE, Embase and Scopus for randomized controlled trials (RCTs) and cohort studies addressing the association between ranolazine and AF outcomes, published up until December 1, 2019. The primary endpoint was incidence of AF, which was evaluated under a ranolazine versus placebo design. In this regard, patients in the setting of postcardiac surgery were further investigated separately. Secondary endpoints included AF cardioversion outcomes, which were addressed through comparison between ranolazine plus amiodarone and amiodarone alone for proportional efficacy and temporal requirements (time-to-cardioversion). The latter analysis was also undertaken in a dose-sensitive fashion (≤1000mg vs. 1500mg of ranolazine). Tertiary endpoints covered AF burden and episodes, in paroxysmal AF patients, and safety outcomes, namely death, QTc interval prolongation and hypotension. Study-specific odds ratios (ORs) were pooled using meta-analytic techniques with a random-effects model. Results A total of 10 RCTs comprising 8.109 participants and 3 cohort studies encompassing 37.112 patients were regarded as eligible for evaluation. Ranolazine was found to attenuate patients' odds of developing AF (OR 0.53, 95% CI: 0.41–0.69, p<0.001, i2=58%). This effect held true, with an even larger effect size, in the context of post-cardiac surgery (OR 0.34, 95% CI: 0.16–0.72, p=0.005, i2=64%). Ranolazine increased the chances of successful AF cardioversion when added to amiodarone over amiodarone alone (OR 6.67, 95% CI: 1.49–29.89, p=0.01, i2=76%), while significantly reducing time-to-cardioversion [SMD 9.54h, 95% CI: −13.3–5.75, p<0.001, i2=99%]. Interestingly, cardioversion was faster with ≤1000mg of ranolazine (SMD −13.16h, 95% CI: −15.07–11.25, p<0.001, i2=95%) than with 1500mg (SMD −3.57h, 95% CI: −5.06–2.08, p<0.001, i2=23%). In paroxysmal AF, ranolazine was also proved to significantly reduce both AF burden and episodes. There were no safety signals regarding mortality odds, QTc interval prolongation (mostly clinically insignificant) and hypotension (mostly transitory). Conclusion Current evidence suggests that ranolazine provides an effective and safe option for a chemical rhythm control strategy in AF management, a field in which medical breakthroughs are desperately needed. Funding Acknowledgement Type of funding source: None


JMIR Cardio ◽  
10.2196/14857 ◽  
2020 ◽  
Vol 4 (1) ◽  
pp. e14857 ◽  
Author(s):  
Tomohiko Inui ◽  
Hiroki Kohno ◽  
Yohei Kawasaki ◽  
Kaoru Matsuura ◽  
Hideki Ueda ◽  
...  

Background Wearable devices with photoplethysmography (PPG) technology can be useful for detecting paroxysmal atrial fibrillation (AF), which often goes uncaptured despite being a leading cause of stroke. Objective This study is the first part of a 2-phase study that aimed at developing a method for immediate detection of paroxysmal AF using PPG-integrated wearable devices. In this study, the diagnostic performance of 2 major smart watches, Apple Watch Series 3 and Fitbit (FBT) Charge HR Wireless Activity Wristband, each equipped with a PPG sensor, was compared, and the pulse rate data outputted from those devices were analyzed for precision and accuracy in reference to the heart rate data from electrocardiography (ECG) during AF. Methods A total of 40 subjects from patients who underwent cardiac surgery at a single center between September 2017 and March 2018 were monitored for postoperative AF using telemetric ECG and PPG devices. AF was diagnosed using a 12-lead ECG by qualified physicians. Each subject was given a pair of smart watches, Apple Watch and FBT, for simultaneous pulse rate monitoring. The heart rate of all subjects was also recorded on the telemetry system. Time series pulse rate trends and heart rate trends were created and analyzed for trend pattern similarities. Those trend data were then used to determine the accuracy of PPG-based pulse rate measurements in reference to ECG-based heart rate measurements during AF. Results Of the 20 AF events in group FBT, 6 (30%) showed a moderate or higher correlation (cross-correlation function>0.40) between pulse rate trend patterns and heart rate trend patterns. Of the 16 AF events in group Apple Watch (workout [W] mode), 12 (75%) showed a moderate or higher correlation between the 2 trend patterns. Linear regression analyses also showed a significant correlation between the pulse rates and the heart rates during AF in the subjects with Apple Watch. This correlation was not observed with FBT. The regression formula for Apple Watch W mode and FBT was X=14.203 + 0.841Y and X=58.225 + 0.228Y, respectively (where X denotes the mean of all average pulse rates during AF and Y denotes the mean of all corresponding average heart rates during AF), and the coefficient of determination (R2) was 0.685 and 0.057, respectively (P<.001 and .29, respectively). Conclusions In this validation study, the detection precision of AF and measurement accuracy during AF were both better with Apple Watch W mode than with FBT.


2019 ◽  
Author(s):  
Tomohiko Inui ◽  
Hiroki Kohno ◽  
Yohei Kawasaki ◽  
Kaoru Matsuura ◽  
Hideki Ueda ◽  
...  

BACKGROUND Wearable devices with photoplethysmography (PPG) technology can be useful for detecting paroxysmal atrial fibrillation (AF), which often goes uncaptured despite being a leading cause of stroke. OBJECTIVE This study is the first part of a 2-phase study that aimed at developing a method for immediate detection of paroxysmal AF using PPG-integrated wearable devices. In this study, the diagnostic performance of 2 major smart watches, Apple Watch Series 3 and Fitbit (FBT) Charge HR Wireless Activity Wristband, each equipped with a PPG sensor, was compared, and the pulse rate data outputted from those devices were analyzed for precision and accuracy in reference to the heart rate data from electrocardiography (ECG) during AF. METHODS A total of 40 subjects from patients who underwent cardiac surgery at a single center between September 2017 and March 2018 were monitored for postoperative AF using telemetric ECG and PPG devices. AF was diagnosed using a 12-lead ECG by qualified physicians. Each subject was given a pair of smart watches, Apple Watch and FBT, for simultaneous pulse rate monitoring. The heart rate of all subjects was also recorded on the telemetry system. Time series pulse rate trends and heart rate trends were created and analyzed for trend pattern similarities. Those trend data were then used to determine the accuracy of PPG-based pulse rate measurements in reference to ECG-based heart rate measurements during AF. RESULTS Of the 20 AF events in group FBT, 6 (30%) showed a moderate or higher correlation (cross-correlation function&gt;0.40) between pulse rate trend patterns and heart rate trend patterns. Of the 16 AF events in group Apple Watch (workout [W] mode), 12 (75%) showed a moderate or higher correlation between the 2 trend patterns. Linear regression analyses also showed a significant correlation between the pulse rates and the heart rates during AF in the subjects with Apple Watch. This correlation was not observed with FBT. The regression formula for Apple Watch W mode and FBT was X=14.203 + 0.841Y and X=58.225 + 0.228Y, respectively (where X denotes the mean of all average pulse rates during AF and Y denotes the mean of all corresponding average heart rates during AF), and the coefficient of determination (<i>R</i><sup>2</sup>) was 0.685 and 0.057, respectively (<i>P</i>&lt;.001 and .29, respectively). CONCLUSIONS In this validation study, the detection precision of AF and measurement accuracy during AF were both better with Apple Watch W mode than with FBT.


Author(s):  
Lisa Y. W. Tang ◽  
Nathaniel M. Hawkins ◽  
Kendall Ho ◽  
Roger Tam ◽  
Marc W. Deyell ◽  
...  

Background The natural history of autonomic alterations following catheter ablation of drug‐refractory paroxysmal atrial fibrillation is poorly defined, largely because of the historical reliance on non‐invasive intermittent rhythm monitoring for outcome ascertainment. Methods and Results The study included 346 patients with drug‐refractory paroxysmal atrial fibrillation undergoing pulmonary vein isolation using contemporary advanced‐generation ablation technologies. All patients underwent insertion of a Reveal LINQ (Medtronic) implantable cardiac monitor before ablation. The implantable cardiac monitor continuously recorded physical activity, heart rate variability (measured as the SD of the average normal‐to‐normal), daytime heart rate, and nighttime heart rate. Longitudinal autonomic data in the 2‐month period leading up to the date of ablation were compared with the period from 91 to 365 days following ablation. Following ablation there was a significant decrease in SD of the average normal‐to‐normal (mean difference versus baseline of 19.3 ms; range, 12.9–25.7; P <0.0001), and significant increases in daytime and nighttime heart rates (mean difference versus baseline of 9.6 bpm; range, 7.4–11.8; P <0.0001, and 7.4 bpm; range, 5.4–9.3; P <0.0001, respectively). Patients free of arrhythmia recurrence had significantly faster daytime (11±11 versus 8±12 bpm, P =0.001) and nighttime heart rates (8±9 versus 6±8 bpm, P =0.049), but no difference in SD of the average normal‐to‐normal ( P =0.09) compared with those with atrial fibrillation recurrence. Ablation technology and cryoablation duration did not influence these autonomic nervous system effects. Conclusions Pulmonary vein isolation results in significant sustained changes in the heart rate parameters related to autonomic function. These changes are correlated with procedural outcome and are independent of the ablation technology used. Registration URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01913522.


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
A Abu Rmilah ◽  
G Lin ◽  
J Hermann

Abstract Objective QTc interval prolongation can lead to life-threatening complications such as torsade de pointes (TdP), ventricular tachycardia (VT), and sudden cardiac death (SCD). It can occur with various tyrosine kinase inhibitors (TKIs) but comparative analyses on the incidence and complication rates are scarce. We thus conducted a comprehensive analysis of TKI use and QTc prolongation in clinical practice. Methods We retrospectively reviewed the electronic medical records of all cancer patients who were treated with TKI between 01/2005 and 12/2018 at our institution. QTc prolongation was defined as a QTc ≥450 ms or 460 ms among male or female patients, respectively. For each type of TKIs, we determined the administration rate and incidence of QTc interval prolongation. We also studied the frequency of QTc prolongation ≥500 ms, the rate of increase of the QTc interval by ≥60 ms, and the development of complications (VT, TdP, and SCD). Results In the present study, we analyzed the data of 685 cancer patients (431 male and 254 female), including 299 patients with RCC, 188 with chronic leukemia, 55 with acute leukemia, 65 with thyroid cancer, 48 with lung cancer and 39 with GIST. These patients received 902 TKI administrations and QTc prolongation was reported in 1/3 of these (289 administrations). The highest frequency was seen with imatinib, nilotinib, and dasatinib (30, 40 and 50%). Among cases of QTc prolongation, a QTc interval ≥500 ms was documented in 53 (18.3%) and QTc progression ≥60 ms in 72 (25%). Complications were found in 14 cases (5%) including VT in 9, TdP in 2 and SCD in 3 administrations. Table 1 demonstrates the findings for each TKI. Findings for TKIs in all patients Total Prolonged QTc QTc ≥500 QTc progression ≥60 VT SCD TdP Imatinib 165 54 13 10 2 Nilotinib 75 33 8 19 Dasatinib 115 58 10 16 2 1 Sunitinib 134 31 1 2 1 1 Pazopanib 165 36 5 6 2 1 Others 248 77 16 18 2 1 1 Conclusion The current findings suggest that TKI therapy leads to QTc prolongation in 1/3 of patients on average and most commonly with the Bcr-Abl TKIs, imatinib, nilotinib, and dasatinib. While SCD is rare (1%) it can still evolve and in 5% of all QTc prolongations with TKIs are potentially life-threatening. These data support recommendations for serial ECGs in cancer patients undergoing TKI therapy. Acknowledgement/Funding None


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
A Chikata ◽  
T Kato ◽  
K Ududa ◽  
S Fujita ◽  
K Otowa ◽  
...  

Abstract Introduction Pulmonary vein isolation (PVI) affects ganglionated plexi (GP) around the atrium, leading to a modification of the intrinsic cardiac autonomic system (ANS). In animal models, GP ablation has a potential risk of QT prolongation and ventricular arrhythmias. However, the impact of PVI on QT intervals in humans remains unclear. Purpose This study aims to evaluate the Impact of PVI on QT interval in patients with paroxysmal atrial fibrillation. Methods We analyzed consecutive 117 PAF patients for their first PVI procedures. 12-lead ECG was evaluated at baseline, 4 hr, day 1, 1 month, and 3 months after ablation. Only patients with sinus rhythm on 12-lead ECG at each evaluation point without antiarrhythmic drugs were included. Results Heart rate significantly increased at 4 hr, day 1, and 1 month. Raw QT interval prolonged at 4 hr (417.1±41.6 ms, P&lt;0.001) but shortened at day 1 (376.4±34.1 ms, P&lt;0.001), 1 month (382.2±31.5 ms, P&lt;0.001), and 3 months (385.1±32.8 ms, P&lt;0.001) compared to baseline (391.6±31.4 ms). Bazett- and Fridericia- corrected QTc intervals significantly prolonged at 4hr (Bazett: 430.8±27.9 ms, P&lt;0.001; Fridericia: 425.8±27.4 ms, P&lt;0.001), day1 (Bazett: 434.8±22.3 ms, P&lt;0.001; Fridericia: 414.1±23.7 ms, P&lt;0.001), 1M (Bazett: 434.8±22.3 ms, P&lt;0.001; Fridericia: 408.2±21.0 ms, P&lt;0.05), and 3M (Bazett: 420.1±21.8 ms, P&lt;0.001; Fridericia: 407.8±21.1 ms, P&lt;0.05) compared to baseline (Bazett: 404.9±25.2 ms; Fridericia: 400.0±22.6 ms). On the other hand, Framingham- and Hodges- corrected QTc interval significantly prolonged only at 4hr (Framingham: 424.1±26.6 ms, P&lt;0.001; Hodges: 426.8±28.4 ms, P&lt;0.001) and at day1 (Framingham: 412.3±29.3 ms, P&lt;0.01; Hodges: 410.6±40.2 ms, P&lt;0.05) compared to baseline (Framingham: 399.2±22.7 ms; Hodges: 400.7±22.8 ms). At 4 hr after ablation, raw QT and QTc of all formulas significantly prolonged than baseline. Raw QT and QTc prolongation at 4hr after ablation were more frequently observed in female patients. Multiple regression analysis revealed that female patient is a significant predictor of raw QT and QTc interval prolongation of all formulas 4hr after PVI. Conclusions Raw QT and QTc prolonged after PVI, especially in the acute phase. Female patient is a risk factor for QT prolongation in the acute phase after PVI. Funding Acknowledgement Type of funding source: None


Sign in / Sign up

Export Citation Format

Share Document