scholarly journals P1138Cardiac shear wave velocity in healthy individualsP1139Do still we need E/E prime ratio in predicting left ventricular filling pressures in heart failure with reduced ejection fraction?P1140Evaluation of myocardial dysfunction in children with Beta Thalassemia majorP1141Association of left ventricular size and septal mechanics with right ventricular function and transplant-free survival in infants with hypoplastic left heart syndromeP1142Predictive value of speckle tracking of chronic rejection in middle-aged heart transplant patientsP1143Determinants of the left atrial stiffness in systemic sclerosisP1144Could right atrial peak global longitudinal strain be useful in assessment of right heart function in pulmonary arterial hypertension?P1145Utility of speckle tracked strain assessment of the right ventricle following lung resectionP1146Edge-to-edge-repair in patients with dilated cardiomyopathy and secondary mitral regurgitation: effect on myocardial function as assessed by echocardiographic speckle tracking analysisP1147Decongestion, arterial stiffness and ventricular-arterial coupling in AHFP1148Myocardial disfunction in Anderson-Fabry disease (AFD) without left ventricular hypertrophyP1149Assessment of left ventricular twist-untwist mechanics in cardiac amyloidosis using three-dimensional speckle-tracking echocardiographyP1150Three-dimensional principal strain analysis for the dependency of preload changes

2016 ◽  
Vol 17 (suppl 2) ◽  
pp. ii242-ii245 ◽  
Author(s):  
M. Strachinaru ◽  
G. Romano ◽  
AA. Tantawy ◽  
D. Forsha ◽  
R. Pavasini ◽  
...  
2010 ◽  
Vol 299 (3) ◽  
pp. H664-H672 ◽  
Author(s):  
Noa Bachner-Hinenzon ◽  
Offir Ertracht ◽  
Marina Leitman ◽  
Zvi Vered ◽  
Sara Shimoni ◽  
...  

The rat heart is commonly used as an experimental model of the human heart in both health and disease states, assuming that heart function of rats and humans is alike. When studying a rat model, echocardiography is usually performed on sedated rats, whereas standard echocardiography on adult humans does not require any sedation. Since echocardiography results of sedated rats are usually inferred to alert humans, in the present study, we tested the hypothesis that differences in left ventricular (LV) function may be present between rats sedated by a low dose of ketamine-xylazine and alert humans. Echocardiography was applied to 110 healthy sedated rats and 120 healthy alert humans. Strain parameters were calculated from the scans using a layer-specific speckle tracking echocardiography program. The results showed that layer longitudinal strain is equal in rats and humans, whereas segmental strain is heterogeneous ( P < 0.05) in a different way in rats and humans ( P < 0.05). Furthermore, layer circumferential strain is larger in humans ( P < 0.001), and the segmental results showed different segmental heterogeneity in rats and humans ( P < 0.05). Radial strain was found to be homogeneous at the apex and papillary muscle levels in humans and heterogeneous in rats ( P < 0.001). Additionally, whereas LV twist was equal in rats and humans, in rats the rotation was larger at the apex ( P < 0.01) and smaller at the base ( P < 0.001). The torsion-to-shortening ratio parameter, which indicates the transmural distribution of contractile myofibers, was found to be equal in rats and humans. Thus, when evaluating LV function of sedated rats under ketamine-xylazine, it is recommended to measure the global longitudinal strain, LV twist, and torsion-to-shortening ratio, since no scaling is required when converting these parameters and inferring them to humans.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Saikrishna Ananthapadmanabhan ◽  
Giau Vo ◽  
Tuan Nguyen ◽  
Hany Dimitri ◽  
James Otton

Abstract Background Cardiac magnetic resonance feature tracking (CMR-FT) and speckle tracking echocardiography (STE) are well-established strain imaging modalities. Multilayer strain measurement permits independent assessment of endocardial and epicardial strain. This novel and layer specific approach to evaluating myocardial deformation parameters may provide greater insight into cardiac contractility when compared to whole-layer strain analysis. The aim of this study is to validate CMR-FT as a tool for multilayer strain analysis by providing a direct comparison between multilayer global longitudinal strain (GLS) values between CMR-FT and STE. Methods We studied 100 patients who had an acute myocardial infarction (AMI), who underwent CMR imaging and echocardiogram at baseline and follow-up (48 ± 13 days). Dedicated tissue tracking software was used to analyse single- and multi-layer GLS values for CMR-FT and STE. Results Correlation coefficients for CMR-FT and STE were 0.685, 0.687, and 0.660 for endocardial, epicardial, and whole-layer GLS respectively (all p < 0.001). Bland Altman analysis showed good inter-modality agreement with minimal bias. The absolute limits of agreement in our study were 6.4, 5.9, and 5.5 for endocardial, whole-layer, and epicardial GLS respectively. Absolute biases were 1.79, 0.80, and 0.98 respectively. Intraclass correlation coefficient (ICC) values showed moderate agreement with values of 0.626, 0.632, and 0.671 respectively (all p < 0.001). Conclusion There is good inter-modality agreement between CMR-FT and STE for whole-layer, endocardial, and epicardial GLS, and although values should not be used interchangeably our study demonstrates that CMR-FT is a viable imaging modality for multilayer strain


Medicina ◽  
2021 ◽  
Vol 57 (6) ◽  
pp. 562
Author(s):  
Rima Šileikienė ◽  
Karolina Adamonytė ◽  
Aristida Ziutelienė ◽  
Eglė Ramanauskienė ◽  
Jolanta Justina Vaškelytė

Background and objectives: Childhood obesity has reached epidemic levels in the world. Obesity in children is defined as a body mass index (BMI) equal to or above the 95th percentile for age and sex. The aim of this study was to determine early changes in cardiac structure and function in obese children by comparing them with their nonobese peers, using echocardiography methods. Materials and methods: The study enrolled 35 obese and 37 age-matched nonobese children. Standardized 2-dimensional (2D), pulsed wave tissue Doppler, and 2D speckle tracking echocardiography were performed. The z-score BMI and lipid metabolism were assessed in all children. Results: Obese children (aged 13.51 ± 2.15 years; 20 boys; BMI z-score of 0.88 ± 0.63) were characterized by enlarged ventricular and atrial volumes, a thicker left ventricular posterior wall, and increased left ventricular mass. Decreased LV and RV systolic and diastolic function was found in obese children. Atrial peak negative (contraction) strain (−2.05% ± 2.17% vs. −4.87% ± 2.97%, p < 0.001), LV and RV global longitudinal strain (−13.3% ± 2.88% vs. −16.87% ± 3.39%; −12.51% ± 10.09% vs. −21.51% ± 7.42%, p < 0.001), and LV global circumferential strain (−17.0 ± 2.7% vs. −19.5 ± 2.9%, p < 0.001) were reduced in obese children. LV torsion (17.94° ± 2.07° vs. 12.45° ± 3.94°, p < 0.001) and normalized torsion (2.49 ± 0.4°/cm vs. 1.86 ± 0.61°/cm, p = 0.001) were greater in obese than nonobese children. A significant inverse correlation was found between LV and RV global longitudinal strain and BMI (r = −0.526, p < 0.01; r = −0.434, p < 0.01) and total cholesterol (r = −0.417, p < 0.01). Multivariate analysis revealed that the BMI z-score was independently related to LV and RV global longitudinal strain as well as LV circumferential and radial strain. Conclusion: 2D speckle tracking echocardiography is beneficial in the early detection of regional LV systolic and diastolic dysfunctions, with preserved ejection fraction as well as additional RV and atrial involvement, in obese children. Obesity may negatively influence atrial and ventricular function, as measured by 2D speckle tracking echocardiography. Obese children, though they are apparently healthy, may have subclinical myocardial dysfunction.


scholarly journals P260Right cardiac chambers remodeling in marathon and ultra-trail athletes detected by speckle-tracking echocardiographyP261Speckle tracking determination of tissue motion annular displacement: comparison with strain and ejection fraction, and association with outcomes in haemodialysis patientsP262Value of right ventricular 2D-speckle tracking parameters in predicting the TIMI flow grade of the RCA in patients with acute RV infarctionP263The correlation between left atrial deformation indices and the CHA2DS2 - VASc risk score in patients with atrial fibrillationP264Right atrial and ventricular function evaluated with speckle tracking in patients with acute pulmonary embolismP265Enhanced accuracy of a speckle tracking strain based artificial intelligence model to differentiate ischaemic myocardial disease and cardiomyopathyP266Detection of early left ventricular and left atrial dysfunction in type I diabetes mellitus using 2D speckle tracking echocardiographyP267Two-dimensional left ventricular global longitudinal strain dynamics after percutaneous coronary intervention in stable single-vessel coronary artery disease patientsP268Left ventricular twist, torsion and strain in the fetus by 3D echocardiography: feasibility and comparisons with 2DP269Left atrial deformation analysis in acromegaly - a three-dimensional speckle-tracking echocardiographic studyP270Impact of hemodialysis on three-dimensional left ventricular myocardial deformation in end-stage renal disease: relationships with preload reductionP271Right atrial function in noncompaction cardiomyopathy - a three-dimensional speckle-tracking echocardiographic studyP272CABG failure in the era of cardiac computed tomography - after 8 years half the patients have at least one graft affected

2016 ◽  
Vol 17 (suppl 2) ◽  
pp. ii45-ii48 ◽  
Author(s):  
K. Ujka ◽  
D Y Y Chiu ◽  
H. Tayel ◽  
SHAIMA Mostafa ◽  
E. Ramberg ◽  
...  

Circulation ◽  
2015 ◽  
Vol 132 (suppl_3) ◽  
Author(s):  
Meihua Zhu ◽  
Cole Streiff ◽  
Tao He ◽  
Muhammad Ashraf ◽  
Jiahui Zhang ◽  
...  

Introduction: Obesity may affect cardiac function, which is hard to detect by traditional echocardiography in the early stages. Speckle tracking imaging (STI) is sensitive to subtle myocardial dysfunction. The aim of this study was to determine the influence of obesity on left ventricular (LV) myocardial function in diet-induced obesity (DIO) mice using two-dimensional (2D) speckle tracking echocardiography (STE). Hypothesis: 2D STE is useful to detect obesity-caused myocardial dysfunction. Methods: Twenty newborn mice were divided into two groups: a DIO group (high-fat diet) and a control group (regular-fat diet). 2D image loops were acquired at the end of each month for 6 months. Global longitudinal strain (GLS) and global circumferential strain (GCS) were analyzed at feeding periods over 3 months and 6 months, and compared between the two groups. Results: The control group gained 64% of its initial weight, while the DIO group gained 82% of its initial weight at the 3 month feeding period; and the two groups gained 88% (control) and 125% (DIO) respectively at 6 months. STE analysis revealed an insignificant decrease in strain values in the DIO mice after 3 months; however, after 6 months, the DIO group demonstrated a significant decrease in strain values (P<0.05) despite normal ejection fractions in both groups. Conclusions: 2D STE is highly feasible to detect the myocardial dysfunction caused by obesity in earlier stage. These strain values appear to be related to the severity of obesity.


2020 ◽  
Vol 21 (Supplement_1) ◽  
Author(s):  
O Seckin ◽  
S Unlu ◽  
G Tacoy

Abstract Background The function of both ventricles have been suggested to be affected in patients with mitral stenosis. In this study, it was aimed to investigate deformation properties of right (RV) and left ventricles (LV) in mild and moderate rheumatic mitral stenosis (MS) patients with three-dimensional speckle tracking echocardiography (3D-STE). Methods A total of 60 patients were included in the study (20 patients with mild MS diagnosis, 20 patients with moderate MS diagnosis and 20 healthy volunteers). Three-dimensional echocardiography datasets were obtained for both ventricles in all patients. An example for RV assessment is shown in Figure 1. LV global longitudinal strain (GLS), LV torsion, RV free wall (FW) LS and interventricular septal (IVS) LS measurements were analyzed. Results The LV ejection fraction (EF), RV fractional area change and tricuspid annular plane systolic excursion values were statistically similar and in the normal range. The LV GLS measurements were significantly different among the groups by being highest in the control group and least in the moderate stenosis group (ANOVA,p &lt; 0.001) (Table 1). Patients with MS showed higher torsional values, correlated with MS severity (ANOVA,p &lt; 0.001) (Table 1). IVS LS, RVFW LS values obtained by RV analysis also differed significantly among groups. The FW-GLS values only showed significant difference between the control group and moderate MS group (Table 1). Conclusion Patients with mitral stenosis showed lower LV-GLS and higher LV torsion values. Although the LV GLS is affected; the LV EF was detected to be normal due to increase in LV torsion. RV deformation indices showed signıficant decrease in correlation with the severity of the mitral stenosis. In conclusion, our data suggest that subclinical LV and RV systolic dysfunction is present in mild-moderate MS patients and this dysfunction can be detected by 3D-STE. Table 1 Parameters Control group Mild MS Moderate MS P LV GLS (%) 23.3 ± 2.08 18.9 ± 1.3 17.5 ± 1.8 &lt;0.001 LV torsion 1.5 ± 0.6 2.1 ± 0.6 2.6 ± 0.5 &lt;0.001 IVS LS (%) 23 ± 3.0% 20 ± 2.6 17.1 ± 2.9 &lt;0.001 RV FW LS (%) 25.4 ± 5 22.7 ± 3.2 21.1 ± 4.8 &lt;0.001 FW; free-wall, GLS; global longitudinal strain, IVS; interventricular septum, LV; left ventricular, RV; right ventricular Abstract 1187 Figure 1


2016 ◽  
Vol 17 (suppl 2) ◽  
pp. ii9-ii11
Author(s):  
O. Mirea ◽  
O. Mirea ◽  
A. Karuzas ◽  
E. Nestaas ◽  
BK. Lakatos ◽  
...  

2018 ◽  
Vol 28 (9) ◽  
pp. 1106-1114 ◽  
Author(s):  
Jing Wang ◽  
Rui-Qi Guo ◽  
Jian-Ying Guo ◽  
Lei Zuo ◽  
Chang-Hui Lei ◽  
...  

AbstractBackgroundWe previously reported four heterozygous missense mutations of MYH7, KCNQ1, MYLK2, and TMEM70 in a single three-generation Chinese family with dual Long QT and hypertrophic cardiomyopathy phenotypes for the first time. However, the clinical course among the family members was various, and the potential myocardial dysfunction has not been investigated.ObjectivesThe objective of this study was to investigate the echocardiographic and electrocardiographic characteristics in a genetic positive Chinese family with hypertrophic cardiomyopathy and further to explore the association between myocardial dysfunction and electric activity, and the identified mutations.MethodsA comprehensive echocardiogram – standard two-dimensional Doppler echocardiography and three-dimensional speckle tracking echocardiography – and electrocardiogram were obtained for members in this family.ResultsAs previously reported, four missense mutations – MYH7-H1717Q, KCNQ1-R190W, MYLK2-K324E, and TMEM70-I147T – were identified in this family. The MYH7-H1717Q mutation carriers had significantly increased left ventricular mass indices, elevated E/e’ ratio, deteriorated global longitudinal stain, but enhanced global circumferential and radial strain compared with those in non-mutation patients (all p<0.05). The KCNQ1-R190W carriers showed significantly prolonged QTc intervals, and the MYLK2-K324E mutation carriers showed inverted T-waves (both p<0.05). However, the TMEM70-I147T mutation carriers had similar echocardiography and electrocardiographic data as non-mutation patients.ConclusionsThree of the identified four mutations had potential pathogenic effects in this family: MYH7-H1717Q was associated with increased left ventricular thickness, elevated left ventricular filling pressure, and altered myocardial deformation; KCNQ1-R190W and MYLK2-K324E mutations were correlated with electrocardiographic abnormalities reflected in long QT phenotype and inverted T-waves, respectively.


Author(s):  
Ferit Onur Mutluer ◽  
Daniel J. Bowen ◽  
Roderick W. J. van Grootel ◽  
Jolien W. Roos-Hesselink ◽  
Annemien E. Van den Bosch

AbstractThree dimensional speckle tracking echocardiography (3D-STE) is a novel modality for the assessment of left ventricular strain (LVS). The aim of our study is to provide single vendor normative strain values measured with 3D-STE in healthy adult caucasians. One hundred fifty-five healthy subjects aged 20 to 72 years (≥ 28 subjects per decile) were prospectively included and examined with 2D and 3D transthoracic echocardiography. In 105 both 3D and 2D-STE were feasible (71%, mean age 44 ± 14 years, 51% female). Mean 3D tangential strain (3D-TS) was − 32 ± 2.9%. 3D global longitudinal strain (3D-GLS) demonstrated a significant but not very strong correlation with 2D-GLS values (− 19.7 ± 1.8% vs − 20.4 ± 2.2%, r = 0.462, p < 0.001). No gender difference was observed in 3D strain parameters. 3D-GLS decreased with increasing age stratum (p = 0.024). LVEF was associated with 3D-TS and 3D-GLS (r =  − 0.819, p ≤ 0.001 for 3D-TS, p =  − 0.477, r < 0.001, p = 0.001 for 3D-GLS). In this single vendor study age and gender-specific normative LV 3D-TS values were reported for healthy adult caucasians. In a significant proportion of the subjects 3D-STE was not feasible, but when feasible, 3D-STE shows excellent association with LVEF, and is therefore a promising novel modality for the assessment of the myocardial function, provided that issues of limited feasibility and temporal resolution are addressed.


2020 ◽  
Vol 21 (Supplement_1) ◽  
Author(s):  
K Shiino ◽  
Y Mori ◽  
N Kawasaki ◽  
C Nakashima ◽  
M Nakashima ◽  
...  

Abstract Background Right atrial (RA) deformation by two-dimensional speckle tracking echocardiography has a relatively new technique to evaluate right heart function with pulmonary hypertension and cardiomyopathy. Reproducibility between observers of this technique is important to develop into a robust and reliable tool. Experience may pose significant challenges. Purpose The aim of this study is to evaluate reproducibility of RA strain (global and regional) between novice and expert. Methods One hundred thirty-three patients (n = 133) underwent 2D-Speckle tracking derived RA strain analysis by 3 independent blinded readers (expert and 2 novices). The novice observers were medical interns with no prior experience in performing strain analysis. Echocardiographic images were acquired from iE33 (Philips Medical System) but were analysed offline using single vendor dependent software (QLAB version 11.0; Philips Medical System). The result of novice observer was calculated by the average of novice observers. RA strain parameters were assessed: global RA strain and segmental (Basal, Mid, Roof). Intraobserver and interobserver analyses were performed using intra class correlation coefficients (ICC) between expert and novice. Results Expert and novice observer demonstrated good interobserver reproducibility of global RA strain (ICC 0.88) and segmental parameters (Basal: ICC 0.89, Mid: ICC 0.87, Roof: ICC 0.84). Of all parameters, the basal segment of RA strain showed the greatest interobserver agreement. Intraobserver agreement for novice observer was excellent for global RA strain and segmental parameters (ICC &gt; 0.88). Conclusions Global RA strain and segmental parameters were highly reproducible by novice and expert strain observer.


Sign in / Sign up

Export Citation Format

Share Document