scholarly journals The PHEMU15 catalogue and astrometric results of the Jupiter's Galilean satellite mutual occultation and eclipse observations made in 2014–2015

2017 ◽  
Vol 474 (4) ◽  
pp. 4730-4739 ◽  
Author(s):  
E Saquet ◽  
N Emelyanov ◽  
V Robert ◽  
J-E Arlot ◽  
P Anbazhagan ◽  
...  
1948 ◽  
Vol 26a (3) ◽  
pp. 137-144 ◽  
Author(s):  
C. W. McLeish

The results are presented of ionosphere measurements made in the region of totality during the eclipse of July 9, 1945. An analysis of the results shows effective recombination coefficients of 1.6 × 10−8 for E region, 1.4 × 10−8 for F1 region, and 1.0 × 10−9 for F2 region. Evidence of a variable coefficient for E region agrees with the suggestion of Massey and others of a high negative ion density at this level.


1983 ◽  
Vol 74 ◽  
pp. 51-59
Author(s):  
Jay H. Lieske

It is known that early (i.e. 17th-l8th century) visual observations of Jupiter's Galilean satellites are approximately as accurate as modern visually observed eclipses (Lieske 1982). In the early days the clocks were the primary source of error while in present days problems related to the Earth's and Jupiter's atmospheres have become the primary limiting factor. The early observations were generally made in local apparent time (i.e. related to the real hour angle of the sun). After the development by Huygens in 1656 of the pendulum clock, these early observations, when reduced to a modern UT system, have been shown to be quite accurate.


1966 ◽  
Vol 24 ◽  
pp. 118-119
Author(s):  
Th. Schmidt-Kaler

I should like to give you a very condensed progress report on some spectrophotometric measurements of objective-prism spectra made in collaboration with H. Leicher at Bonn. The procedure used is almost completely automatic. The measurements are made with the help of a semi-automatic fully digitized registering microphotometer constructed by Hög-Hamburg. The reductions are carried out with the aid of a number of interconnected programmes written for the computer IBM 7090, beginning with the output of the photometer in the form of punched cards and ending with the printing-out of the final two-dimensional classifications.


1994 ◽  
Vol 144 ◽  
pp. 82
Author(s):  
E. Hildner

AbstractOver the last twenty years, orbiting coronagraphs have vastly increased the amount of observational material for the whitelight corona. Spanning almost two solar cycles, and augmented by ground-based K-coronameter, emission-line, and eclipse observations, these data allow us to assess,inter alia: the typical and atypical behavior of the corona; how the corona evolves on time scales from minutes to a decade; and (in some respects) the relation between photospheric, coronal, and interplanetary features. This talk will review recent results on these three topics. A remark or two will attempt to relate the whitelight corona between 1.5 and 6 R⊙to the corona seen at lower altitudes in soft X-rays (e.g., with Yohkoh). The whitelight emission depends only on integrated electron density independent of temperature, whereas the soft X-ray emission depends upon the integral of electron density squared times a temperature function. The properties of coronal mass ejections (CMEs) will be reviewed briefly and their relationships to other solar and interplanetary phenomena will be noted.


1984 ◽  
Vol 75 ◽  
pp. 407-422
Author(s):  
William K. Hartmann

ABSTRACTThe nature of collisions within ring systems is reviewed with emphasis on Saturn's rings. The particles may have coherent icy cores and less coherent granular or frosty surface layers, consistent with thermal eclipse observations. Present-day collisions of such ring particles do not cause catastrophic fragmentation of the particles, although some minor surface erosion and reaccretion is possible. Evolution by collisional fragmentation is thus not as important as in the asteroid belt.


Author(s):  
J. Temple Black ◽  
William G. Boldosser

Ultramicrotomy produces plastic deformation in the surfaces of microtomed TEM specimens which can not generally be observed unless special preparations are made. In this study, a typical biological composite of tissue (infundibular thoracic attachment) infiltrated in the normal manner with an embedding epoxy resin (Epon 812 in a 60/40 mixture) was microtomed with glass and diamond knives, both with 45 degree body angle. Sectioning was done in Portor Blum Mt-2 and Mt-1 microtomes. Sections were collected on formvar coated grids so that both the top side and the bottom side of the sections could be examined. Sections were then placed in a vacuum evaporator and self-shadowed with carbon. Some were chromium shadowed at a 30 degree angle. The sections were then examined in a Phillips 300 TEM at 60kv.Carbon coating (C) or carbon coating with chrom shadowing (C-Ch) makes in effect, single stage replicas of the surfaces of the sections and thus allows the damage in the surfaces to be observable in the TEM. Figure 1 (see key to figures) shows the bottom side of a diamond knife section, carbon self-shadowed and chrom shadowed perpendicular to the cutting direction. Very fine knife marks and surface damage can be observed.


Author(s):  
M. Ashraf ◽  
F. Thompson ◽  
S. Miki ◽  
P. Srivastava

Iron is believed to play an important role in the pathogenesis of ischemic injury. However, the sources of intracellular iron in myocytes are not yet defined. In this study we have attempted to localize iron at various cellular sites of the cardiac tissue with the ferrocyanide technique.Rat hearts were excised under ether anesthesia. They were fixed with coronary perfusion with 3% buffered glutaraldehyde made in 0.1 M cacodylate buffer pH 7.3. Sections, 60 μm in thickness, were cut on a vibratome and were incubated in the medium containing 500 mg of potassium ferrocyanide in 49.5 ml H2O and 0.5 ml concentrated HC1 for 30 minutes at room temperature. Following rinses in the buffer, tissues were dehydrated in ethanol and embedded in Spurr medium.The examination of thin sections revealed intense staining or reaction product in peroxisomes (Fig. 1).


Author(s):  
J.M. Titchmarsh

The advances in recent years in the microanalytical capabilities of conventional TEM's fitted with probe forming lenses allow much more detailed investigations to be made of the microstructures of complex alloys, such as ferritic steels, than have been possible previously. In particular, the identification of individual precipitate particles with dimensions of a few tens of nanometers in alloys containing high densities of several chemically and crystallographically different precipitate types is feasible. The aim of the investigation described in this paper was to establish a method which allowed individual particle identification to be made in a few seconds so that large numbers of particles could be examined in a few hours.A Philips EM400 microscope, fitted with the scanning transmission (STEM) objective lens pole-pieces and an EDAX energy dispersive X-ray analyser, was used at 120 kV with a thermal W hairpin filament. The precipitates examined were extracted using a standard C replica technique from specimens of a 2¼Cr-lMo ferritic steel in a quenched and tempered condition.


Author(s):  
T. R. Dinger

Zirconia (ZrO2) is often added to ceramic compacts to increase their toughness. The mechanisms by which this toughness increase occurs are generally accepted to be those of transformation toughening and microcracking. The mechanism of transformation toughening is based on the presence of metastable tetragonal ZrO2 which transforms to the monoclinic allotrope when stressed by a propagating crack. The decrease in volume which accompanies this transformation effectively relieves the applied stress at the crack tip and toughens the material; microcrack toughening arises from the deflection of a propagating crack around sharply angular inclusions.These mechanisms, however, do not explain the toughness increases associated with the class of composites investigated here. Analytical electron microscopy (AEM) has been used to determine whether solid solution effects could be the cause of this increased toughness. Specimens of a mullite (3Al2O3·2SiO2) + 15 vol. % ZrO2 were prepared by the usual technique of mechanical thinning followed by ion beam milling. All observations were made in a Philips EM400 TEM/STEM microscope fitted with EDXS and EELS spectrometers.


Sign in / Sign up

Export Citation Format

Share Document