scholarly journals Li abundances for solar twins in the open cluster M67

2019 ◽  
Vol 492 (1) ◽  
pp. 245-249
Author(s):  
Marília Carlos ◽  
Jorge Meléndez ◽  
José-Dias do Nascimento ◽  
Matthieu Castro

ABSTRACT We determine lithium (Li) abundances for solar twins in the M67 open cluster to add valuable information about the correlation between Li depletion and stellar age and, then, better understand stellar structure and evolution. We use high resolution and good signal-to-noise ratio spectra to characterize Li depletion in three solar twins from M67, using spectral synthesis in the region of the asymmetric 6707.75 Å Li i feature. The mean Li abundance value of A(Li) = 1.6 ± 0.2 dex for our sample of M67 solar twins (our three stars plus a fourth solar twin from a previous analysis in the literature) presents Li abundance expected for its age. Also, the scatter estimated from the standard deviation of the Li abundances in this work is similar to the typical scatter found in a sample of field solar twins presented in the literature.

1998 ◽  
Vol 39 (1) ◽  
pp. 60-63 ◽  
Author(s):  
T. Nishiharu ◽  
Y. Yamashita ◽  
I. Ogata ◽  
S. Sumi ◽  
K. Mitsuzaki ◽  
...  

Purpose: to compare the value of a retrospective targeted high-resolution spiral CT to the standard reconstruction technique in the assessment of pancreatic diseases Material and Methods: Spiral CT pancreatic images of a standard-size reconstruction protocol were compared prospectively with those of a retrospective targeted high-spatial-resolution reconstruction protocol in 30 patients. Prior to clinical evaluation, a phantom study was performed to evaluate the spatial resolution and signal-to-noise ratio of both protocols Results: the high-resolution protocol achieved a good signal-to-noise ratio with acceptable spatial resolution. Phantom studies revealed increased image noise (+17%) with an increase in spatial resolution (+100%). in patients studied with the high-resolution protocol, the increase in noise was not significant but there was a marked improvement in the definition of small details Conclusion: Images obtained with a targeted high-spatial-resolution reconstruction protocol showed superior lesion definition and vascular opacification compared with those obtained with a standard-size reconstruction protocol. This technique may have potential in the evaluation of small pancreatic abnormalities


1997 ◽  
Vol 51 (5) ◽  
pp. 718-720 ◽  
Author(s):  
O.-P. Sievänen

In this article a new method to estimate optimum filter length in linear prediction is described. Linear prediction was used to enhance resolution of a spectrum. In particular, the dependence of prediction error on filter length has been studied. With calculations of simulated spectra it is shown that the prediction error falls rapidly when the filter length attains its optimum value. This effect is quite pronounced when the spectrum has a good signal-to-noise ratio and the modified covariance method is used to calculate prediction filter coefficients. The method is illustrated with applications to real Raman spectra.


Author(s):  
Michael Radermacher ◽  
Teresa Ruiz

Biological samples are radiation-sensitive and require imaging under low-dose conditions to minimize damage. As a result, images contain a high level of noise and exhibit signal-to-noise ratios that are typically significantly smaller than 1. Averaging techniques, either implicit or explicit, are used to overcome the limitations imposed by the high level of noise. Averaging of 2D images showing the same molecule in the same orientation results in highly significant projections. A high-resolution structure can be obtained by combining the information from many single-particle images to determine a 3D structure. Similarly, averaging of multiple copies of macromolecular assembly subvolumes extracted from tomographic reconstructions can lead to a virtually noise-free high-resolution structure. Cross-correlation methods are often used in the alignment and classification steps of averaging processes for both 2D images and 3D volumes. However, the high noise level can bias alignment and certain classification results. While other approaches may be implicitly affected, sensitivity to noise is most apparent in multireference alignments, 3D reference-based projection alignments and projection-based volume alignments. Here, the influence of the image signal-to-noise ratio on the value of the cross-correlation coefficient is analyzed and a method for compensating for this effect is provided.


1996 ◽  
Vol 75 (6) ◽  
pp. 2280-2293 ◽  
Author(s):  
R. Wessel ◽  
C. Koch ◽  
F. Gabbiani

1. The coding of time-varying electric fields in the weakly electric fish, Eigenmannia, was investigated in a quantitative manner. The activity of single P-type electroreceptor afferents was recorded while the amplitude of an externally applied sinusoidal electric field was stochastically modulated. The amplitude modulation waveform (i.e., the stimulus) was reconstructed from the spike trains by mean square estimation. 2. From the stimulus and the reconstructions we calculated the following: 1) the signal-to-noise ratio and thus an effective temporal bandwidth of the units; 2) the coding fraction, i.e., a measure of the fraction of the time-varying stimulus encoded in single spike trains; and 3) the mutual information provided by the reconstructions about the stimulus. 3. Signal-to-noise ratios as high as 7:1 were observed and the bandwidth ranged from 0 up to 200 Hz, consistent with the limit imposed by the sampling theorem. Reducing the cutoff frequency of the stimulus increased the signal-to-noise ratio at low frequencies, indicating a nonlinearity in the receptors' response. 4. The coding fraction and the rate of mutual information transmission increased in parallel with the standard deviation (i.e., the contrast) of the stimulus as well as the mean firing rate of the units. Significant encoding occurred 20-40 Hz above the spontaneous discharge of a unit. 5. When the temporal cutoff frequency of the stimulus was increased between 80 and 400 Hz, 1) the coding fraction decreased, 2) the rate of mutual information transmission remained constant over the same frequency range, and 3) the reconstructed filter changed. This is in agreement with predictions obtained in a simplified neuronal model. 6. Our results suggest that 1) the information transmitted by single spike trains of primary electrosensory afferents to higherorder neurons in the fish brain depends on the contrast and the cutoff frequency of the stimulus as well as on the mean firing rate of the units; and 2) under optimal conditions, more than half of the information about a Gaussian stimulus that can in principle be encoded is carried in single spike trains of P-type afferents at rates up to 200 bits per second.


1983 ◽  
Vol 54 (6) ◽  
pp. 1579-1584 ◽  
Author(s):  
T. K. Aldrich ◽  
J. M. Adams ◽  
N. S. Arora ◽  
D. F. Rochester

We studied the power spectrum of the diaphragm electromyogram (EMG) at frequencies between 31 and 246 Hz in four young normal subjects and five patients with chronic obstructive lung disease (COPD). Diaphragm EMGs were analyzed during spontaneous breathing and maximum inspiratory efforts to determine the effect of signal-to-noise ratio on the power spectrum and if treadmill exercise to dyspnea was associated with diaphragm fatigue. We found that the centroid frequencies of the power spectra (fc) were strongly correlated (r = 0.93) with ratios of power at high frequencies to power at low frequencies (H/L) for all subjects. Of the two indices, H/L had the largest standard deviation expressed as a percentage of the mean. The mean values of both of these decreased significantly after exercise, fc from 100.2 to 97.3 and H/L from 1.07 to 0.97. Signal-to-noise ratios were higher in maximal inspiratory efforts and after exercise in normal subjects and higher in COPD patients. The signal-to-noise ratio was correlated negatively with fc and H/L, indicating that these indices of the shape of the power spectrum are influenced by signal strength and noise levels as well as muscle function. We conclude that the fc and H/L index similar qualities of the power spectrum, that they are partially determined by the signal-to-noise ratio, and that, in some cases, exercise to dyspnea is associated with apparently mild diaphragm fatigue.


2019 ◽  
Vol 9 (11) ◽  
pp. 2181
Author(s):  
Anuradha Goswami ◽  
Jia-Qian Jiang

This research aims to depict the comparative performance of micropollutants’ removal by FeSO4- and zero-valent iron (Fe(0))-catalytic Fenton oxidation and to explore the possibilities of minimising the sludge production from the process. The emerging micropollutants used for the study were gabapentin, sulfamethoxazole, diuron, terbutryn and terbuthylazine. The Taguchi method, which evaluates the signal-to-noise ratio instead of the standard deviation, was used to develop robust experimental conditions. Though both FeSO4- and Fe(0)-catalytic Fenton oxidation were able to completely degrade the stated micropollutants, the Fe(0)-catalytic Fenton process delivered better removal of dissolved organic carbon (DOC; 70%) than FeSO4 catalytic Fenton oxidation (45%). Fe(0)-catalytic Fenton oxidation facilitated heterogeneous treatment functions, which eliminated toxicity from contaminated solution and there was no recognisable sludge production.


1998 ◽  
Vol 4 (S2) ◽  
pp. 400-401
Author(s):  
R. Wagner ◽  
A.F. de Jong ◽  
A.G. Koster ◽  
R. Morrison ◽  
F. Tothill ◽  
...  

In order to reduce beam damage, biological TEM specimens are often observed at temperatures close to the boiling point of liquid nitrogen (77 K). Recently, encouraging results on single particles as well as on 2D crystals have appeared, derived from images taken near liquid helium temperature (4 K), in dedicated TEMs. At these temperatures the high resolution frequencies are much better preserved, increasing the allowable dose and thus the signal to noise ratio.4 Here we present the design of a new dedicated Philips He-TEM which combines the full functionality of a CM300 TWIN with a vacuum transfer system and a liquid helium cooled specimen holder.A schematic overview of the Cryo-TEM is shown in figure 1. The key differences compared to a standard CM microscope are: 1) The tip of the specimen rod is cooled below 10 K and the rod itself cannot be taken out of the goniometer (CompuStage). 2) The specimen enters the column on the opposite side.


2002 ◽  
Vol 185 ◽  
pp. 236-237
Author(s):  
J.-M. Le Contel ◽  
P. Mathias ◽  
E. Chapellier ◽  
J.-C. Valtier

The star 53 Psc (HD 3379, B2.5IV) has been observed as variable by several authors (Sareyan et al., 1979) with frequencies around 10 c d–1 and has been classified as a β Cephei star. Conversely, other authors (e.g. Percy, 1971) found it to be constant.New high resolution, high signal-to-noise ratio, Spectroscopic observations have been performed at the Observatoire de Haute-Provence in 1996 over 11 nights. The spectral domain covers around 200 Å and is centered on Hδ. Radial velocities were deduced from an auto-correlation technique with a scatter around 0.4kms−1.No high frequency variations are observed. Three frequencies have been detected with a false alarm detection above the 1 % level. A fourth one may be present but its amplitude is below this 1 % level. Results are displayed in Table 1.


Sign in / Sign up

Export Citation Format

Share Document