A three-dimensional skeleton of Goniopholididae from the Late Jurassic of Portugal: implications for the Crocodylomorpha bracing system

2019 ◽  
Vol 189 (2) ◽  
pp. 521-548 ◽  
Author(s):  
E Puértolas-Pascual ◽  
O Mateus

Abstract We here describe an articulated partial skeleton of a small neosuchian crocodylomorph from the Lourinhã Formation (Late Jurassic, Portugal). The skeleton corresponds to the posterior region of the trunk and consists of dorsal, ventral and limb osteoderms, dorsal vertebrae, thoracic ribs and part of the left hindlimb. The paravertebral armour is composed of two rows of paired osteoderms with the lateral margins ventrally deflected and an anterior process for a ‘peg and groove’ articulation. We also compare its dermal armour with that of several Jurassic and Cretaceous neosuchian crocodylomorphs, establishing a detailed description of this type of osteoderms. These features are present in crocodylomorphs with a closed paravertebral armour bracing system. The exceptional 3D conservation of the specimen, and the performance of a micro-CT scan, allowed us to interpret the bracing system of this organism to assess if previous models were accurate. The characters observed in this specimen are congruent with Goniopholididae, a clade of large neosuchians abundant in most semi-aquatic ecosystems from the Jurassic and Early Cretaceous of Laurasia. However, its small size, contrasted with the sizes observed in goniopholidids, left indeterminate whether it could have been a dwarf or juvenile individual. Future histological analyses could shed light on this.

2021 ◽  
Vol 11 (11) ◽  
pp. 5086
Author(s):  
Mazen F. Alkahtany ◽  
Saqib Ali ◽  
Abdul Khabeer ◽  
Shafqat A. Shah ◽  
Khalid H. Almadi ◽  
...  

This study aimed to investigate variations in the root canal morphology of maxillary second premolar (MSP) teeth using microcomputed tomography (micro-CT). Sixty (N = 60) human extracted MSPs were collected and prepared for micro-CT scanning. The duration for scanning a single sample ranged between 30 and 40 min and a three-dimensional (3-D) image was obtained for all the MSPs. The images were evaluated by a single observer who recorded the canal morphology type, number of roots, canal orifices, apical foramina(s), apical delta(s), and accessory canals. The root canal configuration was categorized in agreement with Vertucci’s classification, and any configuration not in agreement with Vertucci’s classification was reported as an “additional canal configuration”. Descriptive statistics (such as mean percentages) were calculated using SPSS software. The most common types agreeing with Vertucci’s classification (in order of highest to lowest incidence) were types I, III, V, VII, II, and VI. The teeth also exhibited four additional configurations that were different from Vertucci’s classification: types 2-3, 1-2-3, 2-1-2-1, and 1-2-1-3. A single root was found in 96.7% and the majority of the samples demonstrated two canals (73.3%). Further, 80% of the teeth showed one canal orifice. The number of apical foramina’s in the teeth was variable, with 56.7% having solitary apical foramen. The accessory canal was found in 33.3%, and apical delta was found in only 20% of the samples. Variable morphology of the MSPs was detected in our study. The canal configuration most prevalent was type 1; however, the results also revealed some additional canal types.


2004 ◽  
Vol 16 (3) ◽  
pp. 249-254 ◽  
Author(s):  
Francis D. Ferdinand ◽  
Mark Heiman ◽  
Sharon Ben-Or ◽  
Andrew J. Curtain ◽  
Scott M. Goldman

2009 ◽  
Vol 79 (4) ◽  
pp. 703-714 ◽  
Author(s):  
Carmen Gonzales ◽  
Hitoshi Hotokezaka ◽  
Yoshinori Arai ◽  
Tadashi Ninomiya ◽  
Junya Tominaga ◽  
...  

Abstract Objective: To investigate the precise longitudinal change in the periodontal ligament (PDL) space width and three-dimensional tooth movement with continuous-force magnitudes in living rats. Materials and Methods: Using nickel-titanium closed-coil springs for 28 days, 10-, 25-, 50-, and 100-g mesial force was applied to the maxillary left first molars. Micro-CT was taken in the same rat at 0, 1, 2, 3, 10, 14, and 28 days. The width of the PDL was measured in the pressure and tension sides from 0 to 3 days. Angular and linear measurements were used to evaluate molar position at day 0, 10, 14, and 28. The finite element model (FEM) was constructed to evaluate the initial stress distribution, molar displacement, and center of rotation of the molar. Results: The initial evaluation of PDL width showed no statistical differences among different force magnitudes. Tooth movement was registered 1 hour after force application and gradually increased with time. From day 10, greater tooth movement was observed when 10 g of force was applied. The FEM showed that the center of rotation in the molar is located in the center of five roots at the apical third of the molar roots. Conclusion: The rat's molar movement mainly consists of mesial tipping, extrusion of distal roots, intrusion of mesial root, palatal inclination, and mesial rotation. Although the initial tooth movement after the application of different force magnitudes until day 3 was not remarkably different, 10 g of force produced more tooth movement compared with heavier forces at day 28.


2007 ◽  
Vol 293 (3) ◽  
pp. H1997-H2003 ◽  
Author(s):  
Xiang-Yang Zhu ◽  
Michael D. Bentley ◽  
Alejandro R. Chade ◽  
Erik L. Ritman ◽  
Amir Lerman ◽  
...  

Changes in the structure of the artery wall commence shortly after exposure to cardiovascular risk factors, such as hypercholesterolemia (HC), but may be difficult to detect. The ability to study vascular wall structure could be helpful in evaluation of the factors that instigate atherosclerosis and its pathomechanisms. The present study tested the hypothesis that early morphological changes in coronary arteries of hypercholesterolemic (HC) pigs can be detected using the novel X-ray contrast agent OsO4 and three-dimensional micro-computed tomography (CT). Two groups of pigs were studied after they were fed a normal or an HC (2% cholesterol) diet for 12 wk. Hearts were harvested, coronary arteries were injected with 1% OsO4 solution, and cardiac samples (6-μm-thick) were scanned by micro-CT. Layers of the epicardial coronary artery wall, early lesions, and perivascular OsO4 accumulation were determined. Leakage of OsO4 from myocardial microvessels was used to assess vascular permeability, which was correlated with immunoreactivity of vascular endothelial growth factor in corresponding histological cross sections. OsO4 enhanced the visualization of coronary artery wall layers and facilitated detection of early lesions in HC in longitudinal tomographic sections of vascular segments. Increased density of perivascular OsO4 in HC was correlated with increased vascular endothelial growth factor expression and suggested increased microvascular permeability. The use of OsO4 as a contrast agent in micro-CT allows three-dimensional visualization of coronary artery wall structure, early lesion formation, and changes in vascular permeability. Therefore, this technique can be a useful tool in atherosclerosis research.


2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Michael Zenzes ◽  
Paul Zaslansky

AbstractMicro-CT provides critical data for musculoskeletal research, yielding three-dimensional datasets containing distributions of mineral density. Using high-resolution scans, we quantified changes in the fine architecture of bone in the spine of young mice. This data is made available as a reference to physiological cancellous bone growth. The scans (n = 19) depict the extensive structural changes typical for female C57BL/6 mice pups, aged 1-, 3-, 7-, 10- and 14-days post-partum, as they attain the mature geometry. We reveal the micro-morphology down to individual trabeculae in the spine that follow phases of mineral-tissue rearrangement in the growing lumbar vertebra on a micrometer length scale. Phantom data is provided to facilitate mineral density calibration. Conventional histomorphometry matched with our micro-CT data on selected samples confirms the validity and accuracy of our 3D scans. The data may thus serve as a reference for modeling normal bone growth and can be used to benchmark other experiments assessing the effects of biomaterials, tissue growth, healing, and regeneration.


Radiology ◽  
1996 ◽  
Vol 200 (3) ◽  
pp. 843-850 ◽  
Author(s):  
K E Smith ◽  
P K Commean ◽  
M W Vannier

2021 ◽  
Author(s):  
Andres Gonzalez ◽  
Zoya Heidari ◽  
Olivier Lopez

Abstract Depositional mechanisms of sediments and post-depositional process often cause spatial variation and heterogeneity in rock fabric, which can impact the directional dependency of petrophysical, electrical, and mechanical properties. Quantification of the directional dependency of the aforementioned properties is fundamental for the appropriate characterization of hydrocarbon-bearing reservoirs. Anisotropy quantification can be accomplished through numerical simulations of physical phenomena such as fluid flow, gas diffusion, and electric current conduction in porous media using multi-scale image data. Typically, the outcome of these simulations is a transport property (e.g., permeability). However, it is also possible to quantify the tortuosity of the media used as simulation domain, which is a fundamental descriptor of the microstructure of the rock. The objectives of this paper are (a) to quantify tortuosity anisotropy of porous media using multi-scale image data (i.e., whole-core CT-scan and micro-CT-scan image stacks) through simulation of electrical potential distribution, diffusion, and fluid flow, and (b) to compare electrical, diffusional, and hydraulic tortuosity. First, we pre-process the images (i.e., CT-scan images) to remove non-rock material visual elements (e.g., core barrel). Then, we perform image analysis to identify different phases in the raw images. Then, we proceed with the numerical simulations of electric potential distribution. The simulation results are utilized as inputs for a streamline algorithm and subsequent direction-dependent electrical tortuosity estimation. Next, we conduct numerical simulation of diffusion using a random walk algorithm. The distance covered by each walker in each cartesian direction is used to compute the direction-dependent diffusional tortuosity. Finally, we conduct fluid-flow simulations to obtain the velocity distribution and compute the direction-dependent hydraulic tortuosity. The simulations are conducted in the most continuous phase of the segmented whole-core CT-scan image stacks and in the segmented pore-space of the micro-CT-scan image stacks. Finally, the direction-dependent tortuosity values obtained with each technique are employed to assess the anisotropy of the evaluated samples. We tested the introduced workflow on dual energy whole-core CT-scan images and on smaller scale micro-CT-scan images. The whole-core CT-scan images were obtained from a siliciclastic depth interval, composed mainly by spiculites. Micro-CT-scan images we obtained from Berea Sandstone and Austin Chalk formations. We observed numerical differences in the estimates of direction-dependent electrical, diffusional, and hydraulic tortuosity for both types of image data employed. The highest numerical differences were observed when comparing electrical and hydraulic tortuosity with diffusional tortuosity. The observed differences were significant specially in anisotropic samples. The documented comparison provides useful insight in the selection process of techniques for estimation of tortuosity. The use of core-scale image data in the proposed workflow provides semi-continuous estimates of tortuosity and tortuosity anisotropy which is typically not attainable when using pore-scale images. Additionally, the semi-continuous nature of the tortuosity and tortuosity anisotropy estimates in whole-core CT-scan image data provides an excellent tool for the selection of core plugs coring locations.


Sign in / Sign up

Export Citation Format

Share Document