scholarly journals Determination of carcinogenic herbicides in milk samples using green non-ionic silicone surfactant of cloud point extraction and spectrophotometry

2018 ◽  
Vol 5 (4) ◽  
pp. 171500 ◽  
Author(s):  
N. I. Mohd ◽  
N. N. M. Zain ◽  
M. Raoov ◽  
S. Mohamad

A new cloud point methodology was successfully used for the extraction of carcinogenic pesticides in milk samples as a prior step to their determination by spectrophotometry. In this work, non-ionic silicone surfactant, also known as 3-(3-hydroxypropyl-heptatrimethylxyloxane), was chosen as a green extraction solvent because of its structure and properties. The effect of different parameters, such as the type of surfactant, concentration and volume of surfactant, pH, salt, temperature, incubation time and water content on the cloud point extraction of carcinogenic pesticides such as atrazine and propazine, was studied in detail and a set of optimum conditions was established. A good correlation coefficient ( R 2 ) in the range of 0.991–0.997 for all calibration curves was obtained. The limit of detection was 1.06 µg l −1 (atrazine) and 1.22 µg l −1 (propazine), and the limit of quantitation was 3.54 µg l −1 (atrazine) and 4.07 µg l −1 (propazine). Satisfactory recoveries in the range of 81–108% were determined in milk samples at 5 and 1000 µg l −1 , respectively, with low relative standard deviation, n  = 3 of 0.301–7.45% in milk matrices. The proposed method is very convenient, rapid, cost-effective and environmentally friendly for food analysis.

2013 ◽  
Vol 2013 ◽  
pp. 1-7 ◽  
Author(s):  
Boonyadist Vongsak ◽  
Pongtip Sithisarn ◽  
Wandee Gritsanapan

Moringa oleiferaLamarck (Moringaceae) is used as a multipurpose medicinal plant for the treatment of various diseases. Isoquercetin, astragalin, and crypto-chlorogenic acid have been previously found to be major active components in the leaves of this plant. In this study, a thin-layer-chromatography (TLC-)densitometric method was developed and validated for simultaneous quantification of these major components in the 70% ethanolic extracts ofM. oleiferaleaves collected from 12 locations. The average amounts of crypto-chlorogenic acid, isoquercetin, and astragalin were found to be 0.0473, 0.0427, and 0.0534% dry weight, respectively. The method was validated for linearity, precision, accuracy, limit of detection, limit of quantitation, and robustness. The linearity was obtained in the range of 100–500 ng/spot with a correlation coefficient (r) over 0.9961. Intraday and interday precisions demonstrated relative standard deviations of less than 5%. The accuracy of the method was confirmed by determining the recovery. The average recoveries of each component from the extracts were in the range of 98.28 to 99.65%. Additionally, the leaves from Chiang Mai province contained the highest amounts of all active components. The proposed TLC-densitometric method was simple, accurate, precise, and cost-effective for routine quality controlling ofM. oleiferaleaf extracts.


2015 ◽  
Vol 69 (4) ◽  
Author(s):  
Teodora S. Stefanova ◽  
Kiril K. Simitchiev ◽  
Kiril B. Gavazov

AbstractLiquid-liquid extraction (LLE) and cloud point extraction (CPE) of vanadium(V) ternary complexes with 4-(2-pyridylazo)resorcinol (PAR) and 2,3,5-triphenyl-2H-tetrazolum chloride (TTC) were investigated. The optimal conditions for vanadium extraction and spectrophotometric determination were identified. The composition (V : PAR : TTC) of the extracted species was 1 : 2 : 3 (optimal conditions; LLE), 2 : 2 : 2 (low reagents concentrations; LLE), 1 : 1 : 1 (short heating time; CPE), and 1 : 1 : 1 + 1 : 1 : 0 (optimal extraction conditions; CPE). LLE, performed in the presence of 1,2-diaminocyclohexane-N,N,N’,N’-tetraacetic acid and NH4F as masking agents, afforded the sensitive, selective, precise, and inexpensive spectrophotometric determination of vanadium. The absorption maximum, molar absorptivity, limit of detection, and linear working range were 559 nm, 1.95 × 105 dm3 mol−1 cm−1, 0.7 ng cm−3, and 2.2-510 ng cm−3, respectively. The procedure thus developed was applied to the analysis of drinking waters and steels. The relative standard deviations for V(V) determination were below 9.4 % (4-6 × 10−7 mass %; water samples) and 2.12 % (1-3 mass %; steel samples).


2013 ◽  
Vol 634-638 ◽  
pp. 1586-1590
Author(s):  
Su Fang Wang ◽  
Shou Jie Zhang ◽  
Chun Hong Dong ◽  
Guo Qing Wang ◽  
Jun Feng Guo ◽  
...  

A method for simultaneous determination of residuals of four herbicides and pesticides, simazine, carboxin, diflubenzuron and rotenone, in Chinese green tea was developed. In the proposed method, the tea powder was placed in a centrifuge tube with a plug, extracted in saturated aqueous sodium chloride solution and acetonitrile, agitated using vortex oscillator, and then centrifuged 5 min at 4000 rpm. The supernatant solution was purified by primary secondary amine (PSA) sorbent, C18 power, and graphitized carbon black powder, respectively. Then the purified extracts were dissolved with acetonitrile:0.1% formic acid aqueous solution (40:60, V/V) and agitated, filtered using a syringe with 0.22 μm nylon filter prior to UPLC-MS/MS analysis. The UPLC analysis was performed on an ACQUITY UPLC® HSS T3 column (2.1 mm×100 mm, 1.8 µm), using acetonitrile-0.1% formic acid as mobile phase with the flow rate as 0.3 mL•min-1. Injection volume was 10 µL. Positive ionization mode was applied, and the ions were monitored in the multiple reaction monitoring (MRM) mode with curtain gas 0.069 MPa, collision gas 0.052 MPa, ESI ion spray voltage 5000 V, temperature 550 °C, nebulizer gas 0.24 MPa, and turbo gas 0.28 MPa. The limit of detection (LOD) and limit of quantitation (LOQ) of the proposed method are 1 μg•kg-1and 5 μg•kg-1, respectively. The average recoveries of the four pesticides at 10, 20, and 50 µg•kg-1spiking levels range from 77.4% to 95.3%. TheSupersSuperscript textcript textrelative standard deviation (RSD) (n=6) range form 11.83% to 4.52%.


2017 ◽  
Vol 9 (2) ◽  
pp. 34
Author(s):  
N. Balaji ◽  
Sayeeda Sultana

Objective: An efficient, high performance liquid chromatographic method has been developed and validated for the quantification of related substances in pioglitazone hydrochloride drug substance.Methods: This method includes the determination of three related substances in pioglitazone hydrochloride. The mobile phase A is 0.1% w/v triethylamine in water with pH 2.5 adjusted by dilute phosphoric acid. The mobile phase B is premixed and degassed mixtures of acetonitrile and methanol. The flow rate was 1 ml/min. The elution used was gradient mode. The HPLC column used for the analysis was symmetry C18 with a length of 250 mm, the internal diameter of 4.6 mm and particle size of 5.0 microns.Results: The developed method was found to be linear with the range of 0.006-250% with a coefficient of correlation 0.99. The precision study revealed that the percentage relative standard deviation was within the acceptable limit. The limit of detection and limit of quantitation of the impurities was less than 0.002%and 0.006% with respect to pioglitazone hydrochloride test concentration of 2000 µg/ml respectively. This method has been validated as per ICH guidelines Q2 (R1).Conclusion: A reliable, economical HPLC method was magnificently established for quantitative analysis of related substances of pioglitazone hydrochloride drug substance.


2007 ◽  
Vol 90 (3) ◽  
pp. 720-724
Author(s):  
Sevgi Tatar Ulu

Abstract A sensitive and selective high-performance liquid chromatographic method has been developed for the determination of tianeptine (Tia) in tablets. The method is based on derivatization of Tia with 4-chloro-7-nitrobenzofurazan (NBD-Cl). A mobile phase consisting of acetonitrile10 mM orthophosphoric acid (pH 2.5; 77 + 23) was used at a flow rate of 1 mL/min on a C18 column. The Tia-NBD derivative was monitored using a fluorescence detector, with emission set at 520 nm and excitation at 458 nm. Gabapentin was selected as an internal standard. Linear calibration graphs were obtained in the concentration range of 45300 ng/mL. The lower limit of detection (LOD) was 10 ng/mL at a signal-to-noise ratio of 4. The lower limit of quantitation (LOQ) was 45 ng/mL. The relative standard values for intra- and interday precision were <0.46 and <0.57%, respectively. The recovery of the drug samples ranged between 98.89 and 99.85%. No chromatographic interference from the tablet excipients was found. The proposed method was validated in terms of precision, robustness, recovery, LOD, and LOQ. All the validation parameters were within the acceptance range. The proposed method was applied for the determination of Tia in commercially available tablets. The results were compared with those obtained by an ultraviolet spectrophotometric method using t- and F-tests.


2009 ◽  
Vol 92 (1) ◽  
pp. 302-306 ◽  
Author(s):  
Xiao-Jing Yan ◽  
Xiao-Mei Liang ◽  
Yan-Jun Xu ◽  
Shu-Hui Jin ◽  
Dao-Quan Wang

Abstract A method was developed for the determination of 7B3 (12-propyloxyimino-1,15-pentadecanlactam), a novel macrolactam fungicide, by liquid chromatography/mass spectrometry (LC/MS) with positive electrospray ionization (ESI+). The method used a reversed-phase C18 column and acetonitrilewater (60 + 40, v/v) mobile phase. The quick, easy, cheap, effective, rugged, and safe method was used for extraction of 7B3 from cotton plants, which involved the extraction of 10 g homogenized sample with 10 mL acetonitrile, followed by the addition of 4 g anhydrous MgSO4 and 1.0 g NaCl. After centrifugation, 1 mL of the buffered acetonitrile extract was transferred into a tube containing 50 mg primary secondary amine sorbent and 100 mg anhydrous MgSO4. After shaking and centrifugation, the final extract was transferred to an autosampler vial for concurrent analysis by LC/MS. The results of 7B3 determined by LC/MS in the selective ion monitoring mode were linear, and the matrix effect of the method was evaluated. The average recoveries of 7B3 fortified at different levels were within 84.1100.2, and the relative standard deviations were <7.5 for all samples analyzed. The method limit of detection and the limit of quantitation values were 0.03 and 0.1 mg/kg, respectively. The proposed method was successfully applied to determine 7B3 residues in practical samples. This method is sensitive, accurate, reliable, simple, and safe.


Author(s):  
Jaspreet Kaur ◽  
Daljit Kaur ◽  
Sukhmeet Singh

Objective: A simple, accurate, and selective ultraviolet-spectrophotometric method has been developed for the estimation of febuxostat in the bulk and pharmaceutical dosage forms.Method: The method was developed and validated according to International Conference on Harmonization (ICH Q2 R1) guidelines. The developed method was validated statistically with respect to linearity, range, precision, accuracy, ruggedness, limit of detection (LOD), limit of quantitation (LOQ), and recovery. Specificity of the method was demonstrated by applying different stressed conditions to drug samples such as acid hydrolysis, alkaline hydrolysis, oxidative, photolytic, and thermal degradation.Results: The study was conducted using phosphate buffer pH 6.8 and λmax was found to be 312 nm. Standard plot having a concentration range of 1–10 μg/ml showed a good linear relationship with R2=0.999. The LOD and LOQ were found to be 0.118 μg/ml and 0.595 μg/ml, respectively. Recovery and percentage relative standard deviations were found to be 100.157±0.332% and <2%, respectively.Conclusion: Proposed method was successfully applicable to the pharmaceutical formulations containing febuxostat. Thus, the developed method is found to be simple, sensitive, accurate, precise, reproducible, and economical for the determination of febuxostat in pharmaceutical dosage forms.


2013 ◽  
Vol 2013 ◽  
pp. 1-7 ◽  
Author(s):  
Mohammad Reza Jamali ◽  
Mohammad Gholinezhad ◽  
Saiedeh Balarostaghi ◽  
Reyhaneh Rahnama ◽  
Seyed Hojjat Allah Rahimi

A new, simple, and versatile cloud-point extraction (CPE) methodology has been developed for the separation and preconcentration of cobalt. The cobalt ions in the initial aqueous solution were complexed with 4-Benzylpiperidinedithiocarbamate, and Triton X-114 was added as surfactant. Dilution of the surfactant-rich phase with acidified ethanol was performed after phase separation, and the cobalt content was measured by flame atomic absorption spectrometry. The main factors affecting CPE procedure, such as pH, concentration of ligand, amount of Triton X-114, equilibrium temperature, and incubation time were investigated and optimized. Under the optimal conditions, the limit of detection (LOD) for cobalt was 0.5 μg L-1, with sensitivity enhancement factor (EF) of 67. Calibration curve was linear in the range of 2–150 μg L-1, and relative standard deviation was 3.2% (c=100 μg L-1;n=10). The proposed method was applied to the determination of trace cobalt in real water samples with satisfactory analytical results.


2013 ◽  
Vol 830 ◽  
pp. 345-348
Author(s):  
Lin Gao ◽  
Sheng Jie Chen ◽  
Fang Chen ◽  
Wen Hong Zhou ◽  
Jun Long Yao

A simple, sensitive, green and low cost detection method based on the cloud point extraction (CPE) separation and spectrophotometry was proposed for the determination of lead. In pH=9.0 H3BO3 buffer solution, Pb(II) reacts with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) in the presence of Triton X-100 yielding a hydrophobic complex, which then is extracted into micro-volume surfactant-rich phase. The calibration graph was linear in the range of 20-400 µg/L (at 560 nm). Under the optimized conditions, the detection limits of 10.94 µg/L and the relative standard deviations(RSD) of 2.0% (n=5) for Lead(II) were found, respectively. The sensitivity and absorbance of this method are at least five times higher when compared with that of usual 5-Br-PADAP spectrophotometry without CPE, and the proposed method has been applied to the determination of Lead in environment water samples with satisfactory results.


Sign in / Sign up

Export Citation Format

Share Document