scholarly journals Gender identification in Chicken (Gallus gallus) by PCR using whole blood and dried blood spot on filter paper as template: without prior DNA isolation

2016 ◽  
Author(s):  
S. Dhanasekaran ◽  
G. Dhinakar Raj ◽  
A. R. Vignesh ◽  
S. T. Selvan ◽  
B. Prakash ◽  
...  

AbstractAccurate sex identification of pure line chickens in their early age has significant economic impact in breeding industry. In the recent years, range of Polymerase Chain Reaction (PCR) based sex determination techniques are routinely used to identify the sex of parent lines in breeding industries, however purified DNA is a prerequisite. Hence this study was aimed to develop a rapid and inexpensive PCR based gender identification method for chicken using whole blood samples and dried blood spots as template for PCR without DNA extraction. In addition, practicability of two W-chromosome specific gene targets in chicken for sex determination also characterised. Successful amplification of sex specific fragments and an internal control was achieved with the range of 0.125μl and 0.250μl volume of whole blood on filter paper (~1 mm) prepared from chicken and dried blood spot. This technique does not require DNA extraction, freeze/thawing of blood samples, pre-treatment with any reagents, dilution of whole blood or dried blood spots on filter paper. It can be carried out with commercially available Taq polymerase enzymes with increased concentration of MgCl2 (3 mM) and 0.5% of DMSO without optimisation of PCR buffers. In conclusion, as compared to the existing PCR based sex identification techniques, the present approach is relatively economic, time saving, requires minimal steps and eliminates the need for DNA extraction.

Author(s):  
Olof Beck ◽  
Maria Mellring ◽  
Christian Löwbeer ◽  
Sabina Seferaj ◽  
Anders Helander

AbstractPhosphatidylethanol (PEth) is a group of phospholipids formed in cell membranes following alcohol consumption by action of the enzyme phospholipase D (PLD). PEth measurement in whole blood samples is established as a specific alcohol biomarker with clinical and forensic applications. However, in blood specimens containing ethanol, formation of PEth may continue after sampling leading to falsely elevated concentrations. This study evaluated the use of dried blood spot (DBS) and microsampling specimens to avoid post-sampling formation of PEth. Filter paper cards and three commercial devices for volumetric microsampling of finger-pricked blood were assessed, using PEth-negative and PEth-positive whole blood fortified with 2 g/L ethanol. PEth (16:0/18:1) was measured by LC–MS/MS. Post-sampling formation of PEth occurred in wet blood and in the volumetric devices, but not filter paper cards, when stored at room temperature for 48 h. Addition of an inhibitor of PLD, sodium metavanadate (NaVO3), eliminated post-sampling formation during storage and drying. In conclusion, the present study confirmed previous observations that PEth can be formed in blood samples after collection, if the specimen contains ethanol. The results further demonstrated that post-sampling formation of PEth from ethanol also occurred with commercial devices for volumetric dried blood microsampling. In order for a PEth result not to be questioned, it is recommended to use a PLD inhibitor, whether venous blood is collected in a vacutainer tube or finger-pricked blood is obtained using devices for dried blood microsampling. Graphical abstract


1985 ◽  
Vol 31 (2) ◽  
pp. 235-238 ◽  
Author(s):  
F W Spierto ◽  
T L Hearn ◽  
F H Gardner ◽  
W H Hannon

Abstract Aliquots (0.1 mL) of whole-blood pools prepared to contain various concentrations of phenylalanine were applied to filter-paper collection cards, dried, and stored in sealed bags. We measured the phenylalanine content of the dried blood spots by bioassay, fluorometry, and "high-performance" liquid chromatography, and found that the concentrations remained constant for two years when samples were kept at -20 degrees C or lower. Intra- and interlaboratory studies showed that results for phenylalanine were greater for laboratories using bioassay procedures than for those using fluorometric procedures. Further, CVs (both among- and within-laboratory) obtained with fluorometric procedures were nearly half as great as the CVs obtained by laboratories using bioassay techniques.


1986 ◽  
Vol 32 (5) ◽  
pp. 854-856 ◽  
Author(s):  
F Bassett ◽  
B A Gross ◽  
C J Eastman

Abstract In this method for estimating prolactin, 50 microL of whole blood obtained by finger puncture is spotted onto filter paper and blood-spot samples are "punched out" with a 3-mm (diameter) paper punch. The blood is extracted with aqueous buffers and the prolactin measured in large batches by radioimmunoassay. Results were identical with those for prolactin in serum. Prolactin in blood spots is stable at room temperature for up to one week and for several months at -20 degrees C. This simple technique for obtaining blood samples for prolactin estimation has particular potential for field studies of lactating women.


1994 ◽  
Vol 40 (3) ◽  
pp. 448-453 ◽  
Author(s):  
C M Worthman ◽  
J F Stallings

Abstract We describe direct immunofluorometric assays for luteinizing hormone (hLH) and follicle-stimulating hormone (hFSH) in fingerstick blood spots dried on filter paper, based on modifications of commercially available kits. Determinations are made from 2.5-mm-diameter discs (3 microL of dried blood) punched out from blood spot standards and samples. Sample dose detection limits of the assays (IU/L) are 0.26 for LH and 0.13 for FSH, with mean interassay CVs of 11.6% (LH) and 7.8% (FSH) at low concentrations. Analytical recoveries of added hormone averaged 100% for LH and 95% for FSH. Clinical studies showed that values for blood spots (x) and directly assayed plasma (y) are highly correlated, so that results from blood spots can be converted directly to plasma equivalents, as follows: yLH = 0.07 + 1.90 xLH, and yFSH = 0.424 + 2.207 xFSH. These gonadotropins are stable in blood spots for at least a year under refrigeration; LH for at least 8 weeks and FSH 6 weeks at 22 degrees C; and both hormones for a week at 37 degrees C. These methods thus allow self-sampling, serial sampling, and mailing of specimens.


2007 ◽  
Vol 14 (11) ◽  
pp. 1522-1525 ◽  
Author(s):  
Rita F. Helfand ◽  
Cesar Cabezas ◽  
Emily Abernathy ◽  
Carlos Castillo-Solorzano ◽  
Ana Cecilia Ortiz ◽  
...  

ABSTRACT Most persons with rubella virus-specific immunoglobulin M (IgM)- or IgG-positive sera tested positive (98% [n = 178] and 99% [n = 221], respectively) using paired filter paper dried blood spot (DBS) samples, provided that DBS indeterminate results were called positive. For persons with IgM- or IgG-negative sera, 97% and 98%, respectively, were negative using DBS.


2016 ◽  
Vol 62 (3) ◽  
pp. 466-475 ◽  
Author(s):  
Roanna S George ◽  
Stuart J Moat

Abstract BACKGROUND The analysis of dried blood spots has been used routinely for newborn screening since the early 1970s, and the number of disorders screened has expanded substantially in recent years. However, there is a lack of evidence regarding minimum blood spot quality acceptance criteria for sample analysis. METHODS Blood pools were spiked with phenylalanine, tyrosine, leucine, methionine, octanoylcarnitine, decanoylcarnitine, isovalerylcarnitine, glutarylcarnitine, thyroid-stimulating hormone, and immunoreactive trypsinogen to concentrations at the analytical cutoffs used in UK screening protocols. We evaluated the effect of sample volume applied to the card (10, 20, 50, 75, and 100 μL), punch location (central vs peripheral), and sample quality (double layering, applying blood to both sides of the filter paper, multispotting, applying insufficient sample, and compressing the sample after application). RESULTS Compression of blood spots produced significantly lower results (14%–44%) for all analytes measured (P < 0.001). Smaller blood spots produced significantly lower results (15%–24% for 10-μL vs 50-μL sample size) for all analytes at all concentrations measured (P < 0.001). Results obtained from peripheral punches were higher than those from a central punch, although this did not reach statistical significance for all analytes. Insufficient and multispotted samples demonstrated heterogeneous results. CONCLUSIONS All blood spots containing ≤20 μL (blood spot diameter <8 mm), those in which blood has not fully penetrated the filter paper, and all samples with evidence of compression should be rejected, since there is a risk of producing false-negative results.


Blood ◽  
2015 ◽  
Vol 126 (23) ◽  
pp. 2182-2182 ◽  
Author(s):  
Patrick T. McGann ◽  
Beverly A. Schaefer ◽  
Mary C. Paniagua ◽  
Thad A. Howard ◽  
Russell E. Ware

Abstract Sickle cell disease (SCD) is a common and life-threatening inherited disorder of hemoglobin, affecting over 400,000 newborns annually. The majority of these births occur in low-resource countries, particularly in sub-Saharan Africa, where limited access to accurate diagnostics results in early mortality. Accurate diagnosis of SCD currently relies upon analytical techniques that are relatively expensive and tedious, requiring equipment, electricity, and laboratory expertise. In Africa, outside of referral and regional hospitals, the availability of accurate SCD diagnostics is extremely scarce. A simple, rapid, accurate, and inexpensive point-of-care (POC) method for diagnosing SCD in limited resource settings would represent a tremendous advance for the management of SCD worldwide. We evaluated a novel point-of care SCD immunoassay (Sickle SCANTM, Biomedomics, Inc., Research Triangle Park, NC) that utilizes lateral flow technology and antibody-mediated detection of hemoglobin variants, with the goal of determining the accuracy, sensitivity, specificity, and ease of identifying the presence of hemoglobin A (HbA), hemoglobin S (HbS), and hemoglobin C (HbC) using blood samples from patients with a variety of hemoglobin patterns. Blood samples collected in EDTA were first tested by HPLC to determine the percentages of normal and abnormal hemoglobins and were then tested using Sickle SCAN. Mixtures of specific hemoglobin combinations were also created to determine the sensitivity of the POC assay for detecting low concentrations of HbA, HbS, and HbC. The Sickle SCAN kit includes tubes prefilled with 1.0mL of buffer, which lyses erythrocytes and releases hemoglobin. Whole blood samples were tested by adding 5µL of whole blood from the EDTA tube to the prefilled buffer container, mixing by inverting the tube three times, discarding 3 drops of the mixed solution and then applying 5 drops to the testingcartridge. Dried blood spot samples were also tested by dropping a 3mm punch into the prefilled buffer container, mixing, discarding 3 drops, and applying 5 drops to the testing cartridge. Five minutes after sample application, two independent and masked clinicians visually scored each sample for the presence/absence of each potential band (HbA, HbS, HbC, and Control). Figure 1 illustrates the visual results of common hemoglobin patterns. A total of 50 samples were evaluated using the POC device, including 32 whole blood samples, 7 dried blood spots, and 11 samples artificially created to contain known low concentrations of HbA, HbS, and HbC. Temperature and stability were evaluated using 10 additional samples that were stored at 37C for up to 30 days. In order to identify potential interference by hemoglobin variants, samples included many different types of hemoglobin (HbA2, Hb Bart's, HbD, HbE, HbF, Hb Lepore, Hb Hope, Hb I-Texas, and Hb G-Philadelphia). From whole blood samples, HbA, HbS, and HbC were easily detected in both heterozygous and homozygous samples, but the intensity of individual bands did not correlate with actual percentages. Newborn samples with high fetal hemoglobin (HbF) were also easily and accurately analyzed for the presence of HbA, HbS, and HbC, with no obvious interference from HbF. The presence of common variant hemoglobins also did not cross-react, but both observers noted a faint HbA band for a newborn sample with a HbFE pattern. For samples artificially created to contain low concentrations of HbA, HbS, or HbC, these hemoglobin were detected at concentrations of <5%. Dried blood spot samples also yielded clear positive bands, without loss of sensitivity or specificity. Devices stored at 37C and blood samples stored at 4C for up to one month gave identical results to those stored at room temperature. These analyses indicate that the Sickle SCAN POC device was simple, robust, and highly sensitive and specific for detecting HbA, HbS, and HbC, even in very low percentages. The device easily and rapidly detected common hemoglobins, but was not quantitative. Specificity was excellent even in the presence of HbF and common variants, with the possible exception of HbE. The ability to obtain rapid and accurate results with both liquid blood and dried blood spots, including those with newborn high-HbF phenotypes, suggests that this device is suitable for large-scale screening of SCD in limited resource settings. Figure 1. Figure 1. Disclosures Ware: Eli Lilly: Other: DSMB membership; Biomedomics: Research Funding; Bayer Pharmaceuticals: Consultancy; Bristol Myers Squibb: Research Funding.


Bioanalysis ◽  
2020 ◽  
Vol 12 (2) ◽  
pp. 99-109 ◽  
Author(s):  
Stuart J Moat ◽  
Catherine Dibden ◽  
Lesley Tetlow ◽  
Caroline Griffith ◽  
Jim Chilcott ◽  
...  

Aim: Dried blood spots (DBS) are used for the analysis of more than 2000 biomarkers. We assessed a range of analyte concentrations and diameters of DBS. Materials & methods: DBS samples were created by the application of increasing volumes of whole blood prepared by the UK NEQAS Quality Assurance Laboratory. Samples were analyzed in four separate laboratories. Results: Volumes less than 25 μl (8 mm) and more than 75 μl (14 mm) created unsatisfactory analytical biases. Results obtained from peripheral subpunches tended to be higher than those from a central subpunch. Conclusion: DBS diameters formed from nonvolumetric application of blood to filter paper can be used to assess whether measurement bias will be within acceptable limits according to the analyte being quantified. DBS received for newborn screening in the UK with diameters less than 8 mm and those more than 14 mm should be rejected.


Author(s):  
G Richardson ◽  
D Marshall ◽  
BG Keevil

Background When preparing dried blood spots (DBSs), haematocrit (Hct) can affect the ability of the blood to spread through the filter paper, thus resulting in varying quantities of sample being measured when fixed subpunches of the DBSs are taken. It may be important to predict the sample Hct to correct volume differences. Methods Blood (10  µL) was applied to Perkin Elmer 226® paper. The samples ( n = 165) were allowed to dry for 24 h, and the entire blood spots were cut out. Subpunch analysis was also performed on blood spots prepared from 75  µL EDTA blood, taking 6 mm subpunches centrally and peripherally from the spots ( n = 59). The spots were eluted with 100  µL water, and a 10  µL aliquot of lysate was added to sulfolyser reagent (80  µL) in a microtitre plate. Hb was measured at 550 nm using an ELISA plate reader. DBS samples were compared against blood samples measured on a routine Sysmex XN-9000 analyser. Results The Passing and Bablock regression showed Hct (DBS-predicted) = 0.99 Hct (Sysmex) −0.02, R2 = 0.87. Intra-assay imprecision measured at Hct values of 0.27, 0.40 and 0.52, gave CVs of 4.1%, 2.8% and 4.2%, respectively. Inter-assay imprecision showed CVs of 6.2%, 5.2% and 4.2%, respectively. DBS samples were stable for up to two days at 60℃, one month at room temperature and six months at 4℃. Conclusion This method provides a simple and fast estimation of predicted Hct in dried blood spots.


1981 ◽  
Vol 27 (8) ◽  
pp. 1421-1423 ◽  
Author(s):  
K Miyai ◽  
K Ishibashi ◽  
M Kawashima

Abstract We describe a sensitive, simple, and rapid two-site immunoenzymometric assay for thyrotropin in dried blood samples on filter paper, for use in screening for neonatal primary hypothyroidism. In this method, two dried-blood spots of 3 mm diameter (equivalent to about 5.4 microliter of blood) are incubated overnight with anti-thyrotropin-beta-D-galactosidase complex in an anti-thyrotropin coated tube. Then the enzyme activity in the washed tube is determined fluorophotometrically. The range of thyrotropin measurable is 10 to 160 milli-int. units/L blood. Values for thyrotropin in dried blood samples determined by this method and those determined by radioimmunoassay correlated highly (r = 0.96).