scholarly journals The impact of vital signs on the death of patients with new coronavirus pneumonia: A systematic review and meta-analysis

Author(s):  
Meixia Du ◽  
Jie Zhao ◽  
Xiaochun Yin ◽  
Nadi Zhang ◽  
Guisen Zheng

Background: Assessing the impact of vital signs (blood pressure, body temperature, heart rate, respiratory rate, and oxygen saturation) on the death of patients with new coronavirus pneumonia would provide a simple and convenient method for the monitoring of subsequent illness, and therefore, in some degree reduce treatment costs and increase the cure rate clinically. Methods: Six databases were retrieved. The software R 3.6.2 was used for meta-analysis of the included literature. Results: 12 studies were included, which comprise 8996 patients affected with COVID-19 infection. The meta-analysis study found that blood pressure (MAP, SBP and DBP), heart rate, respiration rate and SpO2 are the risk factors for disease progression in patients with COVID-19. Among them, the increase in MAP and the decrease in SpO2 have the greatest impact on the death of patients with COVID-19 [MAP: MD = 5.66, 95% CI (0.34, 10.98), SpO2: MD = -5.87, 95% CI (-9.17, -2.57), P = 0.0005]. However, comparing the body temperature of the death group and the survival group found that the body temperature was not statistically significant between the two groups [body temperature: MD = 0.21, 95% CI (-0.01, 0.43), P = 0.0661]. Conclusion: The increase in MAP, heart rate and respiratory rate, as well as the decrease in SBP, DBP and SpO2 are all independent risk factors for death in patients with COVID-19. These factors are simple and easy to monitor, and individualized treatment can be given to patients in time, reducing the mortality rate and improving treatment efficiency.

2019 ◽  
Vol 15 (2) ◽  
pp. 173-177
Author(s):  
Zulkifli Ahmad ◽  
Mohd Najeb Jamaludin ◽  
Kamaruzaman Soeed

Vital sign monitoring is an important body measurement to identify health condition and diagnose any disease and illness. In sports, physical exercise will contribute to the changes of the physiological systems, specifically for the vital signs. Therefore, the objective of this study was to determine the effect of physical fatigue exercise on the vital sign parameters. This is significant for the fitness identification and prediction of each individual when performing an exercise. Five male subjects with no history of injuries and random BMI were selected from students of biomedical engineering, Universiti Teknologi Malaysia. Based on the relationship between physical movement and physiology, the parameters considered were heart rate, blood pressure, and body temperature. Subjects were required to run on the treadmill at an initial speed of 4 km/h with an increase of 1 km/h at every 2 minutes interval. The effect of exercise was marked according to the fatigue protocol where the subject was induced to the maximum condition of performance. All parameters were measured twice, for pre and post exercise-induced protocol. The analysis of relationship of each parameter between pre and post fatigue was p<0.05. The results revealed that the heart rate and gap between blood pressure’s systolic and diastolic were greater for all categories except underweight, where the systolic blood pressure dropped to below 100mmHg at the end of exercise. Also, the body temperature was slightly declined to balance the thermoregulatory system with sweating. Hence, the vigorous physical movement could contribute to the active physiological system based on body metabolism. Heart rate and blood pressure presented significant effects from the fatiguing exercise whereas the body temperature did not indicate any distinguishable impact. The results presented might act as the basis of reference for physical exercise by monitoring the vital sign parameters.


Iproceedings ◽  
10.2196/16250 ◽  
2019 ◽  
Vol 5 (1) ◽  
pp. e16250
Author(s):  
Nicole Polanco ◽  
Sharon Odametey ◽  
Neda Derakhshani ◽  
Mark Khachaturian ◽  
Connor Devoe ◽  
...  

Background Wellness devices for health tracking have gained popularity in recent years. Additionally, portable and readily accessible wellness devices have several advantages when compared to traditional medical devices found in clinical environments The VitalWellness device is a portable wellness device that can potentially aide vital sign measuring for those interested in tracking their health. Objective In this diagnostic accuracy study, we evaluated the performance of the VitalWellness device, a wireless, compact, non-invasive device that measures four vital signs (blood pressure (BP), heart rate (HR), respiratory rate (RR), and body temperature using the index finger and forehead. Methods Volunteers age ≥18 years were enrolled to provide blood pressure (BP), heart rate (HR), respiratory rate (RR), and body temperature. We recruited participants with vital signs that fell within and outside of the normal physiological range. A sub-group of eligible participants were asked to undergo an exercise test, aerobic step test and/or a paced breathing test to analyze the VitalWellness device’s performance on vital signs outside of the normal physiological ranges for HR and RR. Vital signs measurements were collected with the VitalWellness device and FDA-approved reference devices. Mean, standard deviation, mean difference, standard deviation of difference, standard error of mean difference, and correlation coefficients were calculated for measurements collected; these measurements were plotted on a scatter plot and a Bland-Altman plot. Sensitivity analyses were performed to evaluate the performance of the VitalWellness device by gender, skin color, finger size, and in the presence of artifacts. Results 265 volunteers enrolled in the study and 2 withdrew before study completion. Majority of the volunteers were female (62%), predominately white (63%), graduated from college or post college (67%), and employed (59%). There was a moderately strong linear relationship between VitalWellness BP and reference BP (r=0.7, P<.05) and VitalWellness RR and reference RR measurements (r=0.7, P<.05). The VitalWellness HR readings were significantly in line with the reference HR readings (r=0.9, P<.05). There was a weaker linear relationship between VitalWellness temperature and reference temperature (r=0.3, P<.05). There were no differences in performance of the VitalWellness device by gender, skin color or in the presence of artifacts. Finger size was associated with differential performance for RR. Conclusions Overall, the VitalWellness device performed well in taking BP, HR, and RR when compared to FDA-approved reference devices and has potential serve as a wellness device. To test adaptability and acceptability, future research may evaluate user’s interactions and experiences with the VitalWellness device at home. In addition, the next phase of the study will evaluate transmitting vital sign information from the VitalWellness device to an online secured database where information can be shared with HCPs within seconds of measurement.


2020 ◽  
Vol 79 (Suppl 1) ◽  
pp. 914.2-914
Author(s):  
S. Boussaid ◽  
M. Ben Majdouba ◽  
S. Jriri ◽  
M. Abbes ◽  
S. Jammali ◽  
...  

Background:Music therapy is based on ancient cross-cultural beliefs that music can have a “healing” effect on mind and body. Research determined that listening to music can increase comfort and relaxation, relieve pain, lower distress, reduce anxiety, improve positive emotions and mood, and decrease psychological symptoms. Music therapy has been used greatly in various medical procedures to reduce associated anxiety and pain. Patients have a high level of anxiety when they are in the hospital, this is the case of patients with rheumatic diseases who consult regularly to have intravenous infusion of biological therapies.Objectives:The purpose of this study was to examine the effectiveness of music therapy on pain, anxiety, and vital signs among patients with chronic inflammatory rheumatic diseases during intravenous infusion of biological drugs.Methods:Fifty patients were divided into two groups: The experimental group G1 (n=25) received drug infusion while lestening to soft music (30 minutes); and the control group G2 (n=25) received only drug infusion. Measures include pain, anxiety, vital signs (blood pressure, heart rate and respiratory rate). The pain was measured using visual analogic scale (VAS). The state-trait anxiety inventory (STAI) was used for measuring anxiety, low anxiety ranges from 20 to 39, the moderate anxiety ranges from 40 to 59, and high anxiety ranges from 60 to 80. Vital signs (systolic blood pressure [SBP], diastolic blood pressure [DBP], heart rate [HR], and respiratory rate [RR]) were measured before, during and immediately after the infusion.Statistical package for social sciences (SPSS) was used for analysis.Results:The mean age in G1 was 44.45 years (26-72) with a sex ratio (M/F) of 0.8. Including the 25 patients, 12 had rheumatoid arthritis, 10 had ankylosing spondylitis and 3 had psoriatic arthritis. The mean disease duration was 8 years. In G2, the mean age was 46 years (25-70) with a sex ratio (M/F) of 0.75, 12 had rheumatoid arthritis, 11 had ankylosing spondylitis and 2 had psoriatic arthritis. The mean disease duration was 7.5 years. The biological drugs used were: Infliximab in 30 cases, Tocilizumab in 12 cases and Rituximab in 8 cases.Before the infusion, the patients of experimental group had a mean VAS of 5/10±3, a mean STAI of 50.62±6.01, a mean SBP of 13.6 cmHg±1.4, a mean DBP of 8.6 cmHg±1, a mean HR of 85±10 and a mean RR of 18±3. While in control group the mean VAS was 5.5±2, the mean STAI was 50.89±5.5, the mean SBP was 13.4±1.2, the mean DBP was 8.8±1.1, the mean HR was 82±8 and the mean RR was 19±2.During the infusion and after music intervention in G1, the mean STAI became 38.35±5 in G1 versus 46.7±5.2 in G2 (p value=0.022), the mean SBP became 12.1±0.5 in G1 versus 13±1 in G2 (p=0.035), the mean DBP became 8.1±0.8 in G1 versus 8.4±0.9 in G2 (p=0.4), the mean HR became 76±9 in G1 versus 78±7 in G2 (p=0.04) and the mean RR became 17.3±2.1 in G1 versus 18.2±1.7 in G2 (p=0.39).This study found a statistically significant decrease in anxiety, systolic blood pressure and heart rate in patients receiving music interventions during biological therapies infusion, but no significant difference were identified in diastolic blood pressure and respiratory rate.Conclusion:The findings provide further evidence to support the use of music therapy to reduce anxiety, and lower systolic blood pressure and heart rate in patients with rheumatic disease during biological therapies infusion.References:[1] Lin, C., Hwang, S., Jiang, P., & Hsiung, N. (2019).Effect of Music Therapy on Pain After Orthopedic Surgery -A Systematic review and Meta-Analysis. Pain Practice.Disclosure of Interests:None declared


Author(s):  
Musyahadah Arum Pertiwi ◽  
I Dewa Gede Hari Wisana ◽  
Triwiyanto Triwiyanto ◽  
Sasivimon Sukaphat

Heart rate and body temperature can be used to determine the vital signs of humans. Heart rate and body temperature are two important parameters used by paramedics to determine the physical health condition and mental condition of a person. Because if your heart rate or body temperature is not normal then you need to make further efforts to avoid things that are not desirable. The purpose of this study is to design a heart rate and body temperature. In this study, the heart rate is detected using a finger sensor which placed on the finger. This sensor detects the heart rate pulses through infrared absorption of blood hemoglobin, and measure the body temperature using a DS18B20 temperature sensor which is placed axially. DS18B20 sensor works by converting temperature into digital data. The measurement results will be displayed on liquid crystal display (LCD) 2 x 16 and the data will be sent to android mobile phone via Bluetooth.  After the comparision beetwen the desain and the standart, the error is 0.46% for beats per minutes (BPM) parameters and 0.31 degrees Celsius for temperature parameters.


Children ◽  
2020 ◽  
Vol 7 (8) ◽  
pp. 89
Author(s):  
Woori Bae ◽  
Kyunghoon Kim ◽  
Bongjin Lee

To effectively use vital signs as indicators in children, the magnitude of deviation from expected vital sign distribution should be determined. The purpose of this study is to derive age-specific centile charts for the heart rate and respiratory rate of the children who visited the emergency department. This study used the Korea’s National Emergency Department Information System dataset. Patients aged <16 years visiting the emergency department between 1 January 2016 and 31 December 2017 were included. Heart rate and respiratory rate centile charts were derived from the population with normal body temperature (36 to <38 °C). Of 1,901,816 data points retrieved from the database, 1,454,372 sets of heart rates and 1,458,791 sets of respiratory rates were used to derive centile charts. Age-specific centile charts and curves of heart rates and respiratory rates showed a decline in heart rate and respiratory rate from birth to early adolescence. There were substantial discrepancies in the reference ranges of Advanced Paediatric Life Support and Pediatric Advanced Life Support guidelines. Age-based heart rate and respiratory rate centile charts at normal body temperature, derived from children visiting emergency departments, serve as new evidence-based data and can be used in follow-up studies to improve clinical care for children.


CJEM ◽  
2020 ◽  
Vol 22 (5) ◽  
pp. 648-651
Author(s):  
Brit Long ◽  
Elisha Targonsky ◽  
Alex Koyfman

A 63-year-old female patient presents with abdominal pain, vomiting, and abdominal distention. She has previously had a cholecystectomy and hysterectomy. She has had no prior similar episodes, and denies fever, hematemesis, or diarrhea. She takes no medications. Vital signs include blood pressure 123/61 mm Hg, heart rate 97, oral temperature 37.2°C, respiratory rate 18, oxygen saturation 97% on room air. Her abdomen is diffusely tender and distended.


2020 ◽  
Vol 34 (10) ◽  
pp. 1155-1162
Author(s):  
Lorena Catarina Del Sant ◽  
Luciana Maria Sarin ◽  
Eduardo Jorge Muniz Magalhães ◽  
Ana Cecília Lucchese ◽  
Marco Aurélio Tuena ◽  
...  

Introduction and objectives: The impact of multiple subcutaneous (s.c.) esketamine injections on the blood pressure (BP) and heart rate (HR) of patients with unipolar and bipolar treatment-resistant depression (TRD) is poorly understood. This study aimed to assess the cardiovascular safety of multiple s.c. doses of esketamine in patients with TRD. Methods: Seventy TRD patients received 394 weekly s.c. esketamine injections in conjunction with oral antidepressant therapy for up to six weeks. Weekly esketamine doses were 0.5, 0.75 or 1.0 mg/kg according to each patient’s response to treatment. Participants were monitored before each treatment and every 15 minutes thereafter for 120 minutes. We assessed systolic blood pressure (SBP), diastolic blood pressure (DBP), and HR measurements for the entire treatment course. Results: BP increased after the first s.c. esketamine injection, reaching maximum mean SBP/DBP levels of 4.87/5.54 mmHg within 30–45 minutes. At the end of monitoring, 120 minutes post dose, vital signs returned to pretreatment levels. We did not detect significant differences in BP between doses of 0.5, 0.75, and 1 mg/kg esketamine. Mean HR did not differ significantly between doses or before and after s.c. esketamine injection. Conclusions: The BP changes observed with repeated s.c. esketamine injections were mild and well tolerated for doses up to 1 mg/kg. The s.c. route is a simple and safe method of esketamine administration, even for patients with clinical comorbidities, including obesity, hypertension, diabetes, and dyslipidemia. However, 14/70 patients experienced treatment-emergent transient hypertension (SBP >180 mmHg and/or a DBP >110 mmHg). Therefore, we strongly recommend monitoring BP for 90 minutes after esketamine dosing. Since s.c. esketamine is cheap, requires less frequent dosing (once a week), and is a simpler procedure compared to intravenous infusions, it might have an impact on public health.


2020 ◽  
Vol 20 (1) ◽  
Author(s):  
Waqas Ahmed Farooqui ◽  
Mudassir Uddin ◽  
Rashid Qadeer ◽  
Kashif Shafique

Abstract Background Acute organophosphorus (OP) poisoning is one of the major causes of mortality among patients presenting to emergency departments in developing countries. Although various predictors of mortality among OP poisoning patients have been identified, the role of repeated measurements of vital signs in determining the risk of mortality is not yet clear. Therefore, the present study examined the relationship between trajectories of vital signs and mortality among OP poisoning patients using latent class growth analysis (LCGA). Methods This was a retrospective cohort study using data for 449 OP poisoning patients admitted to Civil-Hospital Karachi from Aug’10 to Sep’16. Demographic data and vital signs, including body temperature, blood pressure, heart rate, respiratory rate, and partial-oxygen pressure, were retrieved from medical records. The trajectories of vital signs were formed using LCGA, and these trajectories were applied as independent variables to determine the risk of mortality using Cox-proportional hazards models. P-values of < 0.05 were considered statistically significant. Results Data for 449 patients, with a mean age of 25.4 years (range 13–85 years), were included. Overall mortality was 13.4%(n = 60). In trajectory analysis, a low-declining systolic blood pressure, high-declining heart rate trajectory, high-remitting respiratory rate trajectory and normal-remitting partial-oxygen pressure trajectory resulted in the greatest mortality, i.e. 38.9,40.0,50.0, and 60.0%, respectively, compared with other trajectories of the same parameters. Based on multivariable analysis, patients with low-declining systolic blood pressure were three times [HR:3.0,95%CI:1.2–7.1] more likely to die compared with those who had a normal-stable systolic blood pressure. Moreover, patients with a high-declining heart rate were three times [HR:3.0,95%CI:1.5–6.2] more likely to die compared with those who had a high-stable heart rate. Patients with a high-remitting respiratory rate were six times [HR:5.7,95%CI:1.3–23.8] more likely to die than those with a high-stable respiratory rate. Patients with normal-remitting partial oxygen pressure were five times [HR:4.7,95%CI:1.4–15.1] more likely to die compared with those who had a normal-stable partial-oxygen pressure. Conclusion The trajectories of systolic blood pressure, heart rate, respiratory rate and partial-oxygen pressure were significantly associated with an increased risk of mortality among OP poisoning patients.


2021 ◽  
pp. 1357633X2110118
Author(s):  
Nobuyuki Kagiyama ◽  
Makoto Hiki ◽  
Yuya Matsue ◽  
Tomotaka Dohi ◽  
Wataru Matsuzawa ◽  
...  

Introduction In the ongoing COVID-19 pandemic, the development of a system that would prevent the infection of healthcare providers is in urgent demand. We sought to investigate the feasibility and validity of a telemedicine-based system in which healthcare providers remotely check the vital signs measured by patients with COVID-19. Methods Patients hospitalized with confirmed or suspected COVID-19 measured and uploaded their vital signs to secure cloud storage. Additionally, the respiratory rates were monitored using a mat-type sensor placed under the bed. We assessed the time until the values became available on the Cloud and the agreements between the patient-measured vital signs and simultaneous healthcare provider measurements. Results Between 26 May–23 September 2020, 3835 vital signs were measured and uploaded to the cloud storage by the patients ( n=16, median 72 years old, 31% women). All patients successfully learned how to use these devices with a 10-minute lecture. The median time until the measurements were available on the cloud system was only 0.35 min, and 95.2% of the vital signs were available within 5 min of the measurement. The agreement between the patients’ and healthcare providers’ measurements was excellent for all parameters. Interclass coefficient correlations were as follows: systolic (0.92, p<0.001), diastolic blood pressure (0.86, p<0.001), heart rate (0.89, p<0.001), peripheral oxygen saturation (0.92, p<0.001), body temperature (0.83, p<0.001), and respiratory rates (0.90, p<0.001). Conclusions Telemedicine-based self-assessment of vital signs in patients with COVID-19 was feasible and reliable. The system will be a useful alternative to traditional vital sign measurements by healthcare providers during the COVID-19 pandemic.


Sign in / Sign up

Export Citation Format

Share Document