scholarly journals Direct observation of surface-state thermal oscillations in SmB6 oscillators

2018 ◽  
Vol 97 (3) ◽  
Author(s):  
Brian Casas ◽  
Alex Stern ◽  
Dmitry K. Efimkin ◽  
Zachary Fisk ◽  
Jing Xia
2017 ◽  
Vol 8 (1) ◽  
Author(s):  
Biao Yang ◽  
Qinghua Guo ◽  
Ben Tremain ◽  
Lauren E. Barr ◽  
Wenlong Gao ◽  
...  

2008 ◽  
Vol 607 ◽  
pp. 17-21
Author(s):  
D.B. Cassidy ◽  
S.H.M. Deng ◽  
R.G. Greaves ◽  
N. Lopez-Valdez ◽  
V. Meligne ◽  
...  

Recent observations of molecular positronium (Ps2) were based on a correlation between changes in positronium (Ps) lifetime spectra associated with the density of an incident positron beam and the population of a positronium (or positron) surface state. While the evidence for molecule formation is compelling it is nevertheless an indirect observation, and has not provided any information about the properties of Ps2 beyond its likely creation. Here we discuss the prospects for a direct observation via laser spectroscopy of a predicted 1S2P excited molecular state. Such a measurement would provide a direct and unambiguous signal of Ps2 formation and would also allow us to determine some properties of the molecule, namely the lifetime of the excited state and the 1S1S-1S2P energy interval.


Author(s):  
R. W. Anderson ◽  
D. L. Senecal

A problem was presented to observe the packing densities of deposits of sub-micron corrosion product particles. The deposits were 5-100 mils thick and had formed on the inside surfaces of 3/8 inch diameter Zircaloy-2 heat exchanger tubes. The particles were iron oxides deposited from flowing water and consequently were only weakly bonded. Particular care was required during handling to preserve the original formations of the deposits. The specimen preparation method described below allowed direct observation of cross sections of the deposit layers by transmission electron microscopy.The specimens were short sections of the tubes (about 3 inches long) that were carefully cut from the systems. The insides of the tube sections were first coated with a thin layer of a fluid epoxy resin by dipping. This coating served to impregnate the deposit layer as well as to protect the layer if subsequent handling were required.


Author(s):  
John M. Wehrung ◽  
Richard J. Harniman

Water tables in aquifer regions of the southwest United States are dropping off at a rate which is greater than can be replaced by natural means. It is estimated that by 1985 wells will run dry in this region unless adequate artificial recharging can be accomplished. Recharging with surface water is limited by the plugging of permeable rock formations underground by clay particles and organic debris.A controlled study was initiated in which sand grains were used as the rock formation and water with known clay concentrations as the recharge media. The plugging mechanism was investigated by direct observation in the SEM of frozen hydrated sand samples from selected depths.


Author(s):  
N. E. Paton ◽  
D. de Fontaine ◽  
J. C. Williams

The electron microscope has been used to study the diffusionless β → β + ω transformation occurring in certain titanium alloys at low temperatures. Evidence for such a transformation was obtained by Cometto et al by means of x-ray diffraction and resistivity measurements on a Ti-Nb alloy. The present work shows that this type of transformation can occur in several Ti alloys of suitable composition, and some of the details of the transformation are elucidated by means of direct observation in the electron microscope.Thin foils were examined in a Philips EM-300 electron microscope equipped with a uniaxial tilt, liquid nitrogen cooled, cold stage and a high resolution dark field device. Selected area electron diffraction was used to identify the phases present and the ω-phase was imaged in dark field by using a (101)ω reflection. Alloys were water quenched from 950°C, thinned, and mounted between copper grids to minimize temperature gradients in the foil.


Author(s):  
R. E. Worsham ◽  
J. E. Mann ◽  
E. G. Richardson

This superconducting microscope, Figure 1, was first operated in May, 1970. The column, which started life as a Siemens Elmiskop I, was modified by removing the objective and intermediate lenses, the specimen chamber, and the complete vacuum system. The large cryostat contains the objective lens and stage. They are attached to the bottom of the 7-liter helium vessel and are surrounded by two vapor-cooled radiation shields.In the initial operational period 5-mm and 2-mm focal length objective lens pole pieces were used giving magnification up to 45000X. Without a stigmator and precision ground pole pieces, a resolution of about 50-100Å was achieved. The boil-off rate of the liquid helium was reduced to 0.2-0.3ℓ/hour after elimination of thermal oscillations in the cryostat. The calculated boil-off was 0.2ℓ/hour. No effect caused by mechanical or electrical instability was found. Both 4.2°K and 1.7-1.9°K operation were routine. Flux pump excitation and control of the lens were quite smooth, simple, and, apparently highly stable. Alignment of the objective lens proved quite awkward, however, with the long-thin epoxy glass posts used for supporting the lens.


Author(s):  
J.L. Williams ◽  
K. Heathcote ◽  
E.J. Greer

High Voltage Electron Microscope already offers exciting experimental possibilities to Biologists and Materials Scientists because the increased specimen thickness allows direct observation of three dimensional structure and dynamic experiments on effectively bulk specimens. This microscope is designed to give maximum accessibility and space in the specimen region for the special stages which are required. At the same time it provides an ease of operation similar to a conventional instrument.


Author(s):  
B. Jouffrey ◽  
D. Dorignac ◽  
A. Bourret

Since the early works on GP zones and the model independently proposed by Preston and Guinier on the first steps of precipitation in supersaturated solid solution of aluminium containing a few percent of copper, many works have been performed to understand the structure of different stages in the sequence of precipitation.The scheme which is generally admitted can be drawn from a work by Phillips.In their original model Guinier and Preston analysed a GP zone as composed of a single (100) copperrich plane surrounded by aluminum atomic planes with a slightly shorter distance from the original plane than in the solid solution.From X-ray measurements it has also been shown that GP1 zones were not only copper monolayer zones. They could be up to a few atomic planes thick. Different models were proposed by Guinier, Gerold, Toman. Using synchrotron radiation, proposals have been recently made.


1998 ◽  
Vol 3 (2) ◽  
pp. 4-5
Author(s):  
Glenn Pransky

Abstract According to the AMA Guides to the Evaluation of Permanent Impairment, a functional capacity evaluation (FCE) measures an individual's physical abilities via a set of activities in a structured setting and provides objective data about the relationship between an impairment and maximal ability to perform work activities. A key distinction between FCEs and self-reported activities of daily living is that the former involve direct observation by professional evaluators. Numerous devices can quantify the physical function of a specific part of the musculoskeletal system but do not address the performance of whole body tasks in the workplace, and these devices have not been shown to predict accurately the ability to perform all but the simplest job tasks. Information about reliability has been proposed as a way to identify magnification and malingering, but variability due to pain and poor comprehension of instructions may cause variations in assessments. Structured work capacity evaluations involve a set of activities but likely underestimate the individual's ability to do jobs that involve complex or varying activities. Job simulations involve direct observation of an individual performing actual job tasks, require a skilled and experienced evaluator, and raise questions about expense, time, objectivity and validity of results, and interpretation of results in terms of the ability to perform specific jobs. To understand the barriers to return to work, examiners must supplement FCEs with information regarding workplace environment, accommodations, and demotivators.


Sign in / Sign up

Export Citation Format

Share Document