A synchronous sampling system for high precision AC measurements

Author(s):  
F. Overney ◽  
B. Jeanneret ◽  
A. Mortara
Radiocarbon ◽  
2010 ◽  
Vol 52 (2) ◽  
pp. 835-845 ◽  
Author(s):  
M Molnár ◽  
L Haszpra ◽  
É Svingor ◽  
I Major ◽  
I Svetlik

A high-precision atmospheric CO2 monitoring station was developed as a field unit. Within this, an integrating CO2 sampling system was applied to collect samples for radiocarbon measurements. One sampler was installed in the second largest city of Hungary (Debrecen station) and 2 independent 14CO2 sampling lines were installed ∼300 km from Debrecen in a rural site at Hegyhátsál station as independent background references, where high-precision atmospheric CO2 mixing ratios have been measured since 1994. Fossil fuel CO2 content in the air of the large Hungarian city of Debrecen was determined during the winter of 2008 using both the measurements of CO2 mixing ratio and 14C content of air. Fossil fuel CO2 was significantly enhanced at Debrecen relative to the clean-air site at Hegyhátsál.


2014 ◽  
Vol 981 ◽  
pp. 653-656
Author(s):  
Xin Lao Wei ◽  
Bo Zhu ◽  
Bing Pang ◽  
Tong Liu ◽  
Song Wang ◽  
...  

The induced voltage of the long-distance power cable will reach high value, so the metallic sheath of cable should be cross-linked to reduce the induced voltage. It is safe and economic enough but bring out problem of monitoring the situation of insulation. In order to solve the problem, a new method is provied and a monitoring system based on Digital Siganl Processor and Global Positioning System are designed. The composition of system has been introduced, includes the hardware and software design. The results show that the monitoring system can reflect the situation of cable insulation, and the mothod is proved to be validity and feasibility.


2006 ◽  
Vol 3 (1) ◽  
pp. 33-43
Author(s):  
Predrag Petrovic

Synchronous sampling allows alternating current (AC) quantities, such as the root mean square (RMS) values of voltage and power, to be determined with very low uncertainties (on the order of a few parts of 10-6 [1]). In this a new mathematical expression for estimating measurement uncertainties in non ideal synchronization with fundamental frequency AC signals is presented. The obtained results were compared with those obtained with a high-precision instrument for measuring basic AC values. Computer simulation demonstrating the effectiveness of these new expression, are also presented.


2012 ◽  
Vol 241-244 ◽  
pp. 190-193
Author(s):  
Xiao Ming Chang ◽  
Bin Sun ◽  
Shi Xuan Yao

Before using high-precision ADC AD7730 in analog signal sampling system, it’s required to measure the actual resolution if needed. This paper introduces the design of resolution detection system for ADC, which is used to evaluate the resolution performance parameter of ADC. First, a framework of the application system is designed, and specified at the example of 24bit ADC AD7730 application based on the Virtual Instrument Development Environment LabVIEW. Finally, actual resolutions of input channels are given and evaluated.


2014 ◽  
Vol 527 ◽  
pp. 252-258
Author(s):  
Guan Da Liu ◽  
Bo Mo ◽  
De Zhi Zhou ◽  
Shu Cen Du

Brushless DC motor (BLDCM) is adopted in the driving of a three-axis turntable. A high-speed current sampling system plays a vital role in intelligent control. This article firstly describes the working principle of a triple-closed-loop regulation system and emphatically dissects the characteristic of the current-loop among speed-loop and position-loop. Secondly, a signal acquisition-alignment circuit of three phases’ current and voltage is designed. Based on ADS8365, a scheme of high-speed current loop’s precise and synchronous sampling system is provided. Finally, experimental results have proved the validity and practicality of the scheme applied in the control of three-axis turntable.


2014 ◽  
Vol 1008-1009 ◽  
pp. 701-708
Author(s):  
Le Feng Cheng ◽  
Tao Yu

Focus on the increasingly prominent problems of power quality of dedicated users, study on solving electric energy problems, especially for harmonic pollution, was essential. This paper to study the method of testing and calculating electric energy index, then designed hardware to monitor and analyze power quality measurement data. The hardware was developed base on dual DSP2812, which was very advanced digital signal processing chip, and the hardware utilized high precision instantaneous synchronous sampling chip MAX1324, extended RAM and FLASH, RS232 communication circuit, high capacity SD card storage circuit, etc. The dual DSP power quality smart meter was tested and applied in dedicated users and its reliability, practicability, availability and accuracy was authenticated. This smart meter also has advantages of easy to carry, low cost, high precision, easy to promote, etc. can effectively meet power quality management of dedicated users.


Sign in / Sign up

Export Citation Format

Share Document