Noise analysis and characterization of a charge-balancing-based capacitive sensor interface with a resistive reference

Author(s):  
Ruimin Yang ◽  
Stoyan Nihtianov
2020 ◽  
Vol 645 ◽  
pp. A23
Author(s):  
F. Zhao ◽  
G. Lo Curto ◽  
L. Pasquini ◽  
J. I. González Hernández ◽  
J. R. De Medeiros ◽  
...  

Aims. We study the 2D spectral line profile of the High Accuracy Radial Velocity Planet Searcher (HARPS), measuring its variation with position across the detector and with changing line intensity. The characterization of the line profile and its variations are important for achieving the precision of the wavelength scales of 10−10 or 3.0 cm s−1 necessary to detect Earth-twins in the habitable zone around solar-like stars. Methods. We used a laser frequency comb (LFC) with unresolved and unblended lines to probe the instrument line profile. We injected the LFC light – attenuated by various neutral density filters – into both the object and the reference fibres of HARPS, and we studied the variations of the line profiles with the line intensities. We applied moment analysis to measure the line positions, widths, and skewness as well as to characterize the line profile distortions induced by the spectrograph and detectors. Based on this, we established a model to correct for point spread function distortions by tracking the beam profiles in both fibres. Results. We demonstrate that the line profile varies with the position on the detector and as a function of line intensities. This is consistent with a charge transfer inefficiency effect on the HARPS detector. The estimate of the line position depends critically on the line profile, and therefore a change in the line amplitude effectively changes the measured position of the lines, affecting the stability of the wavelength scale of the instrument. We deduce and apply the correcting functions to re-calibrate and mitigate this effect, reducing it to a level consistent with photon noise.


2003 ◽  
Vol 18 (10) ◽  
pp. 2522-2527 ◽  
Author(s):  
E. D. Specht ◽  
A. Rar ◽  
G. M. Pharr ◽  
E. P. George ◽  
P. Zschack ◽  
...  

A technique based on synchrotron radiation was developed that allows for rapid structural and chemical characterization of ternary alloys over a wide range of composition. The technique was applied to isothermal sections of the Cr–Fe–Ni system grown on Al2O3(0001) sapphire substrates by sequential deposition of layers of graded.thickness followed by annealing to interdiffuse the elements. A film spanning the Cr–Fe–Ni ternary system was measured in 4 h at a resolution of 2 at.% by rastering the sample under a focused beam of synchrotron radiation while simultaneously measuring the diffraction pattern with a charge-coupled device detector to determine crystallographic phases, texture, and lattice parameters and also measuring the x-ray fluorescence with an energy-dispersive detector to determine elemental composition. Maps of phase composition and lattice parameter as a function of composition for several annealing treatments were found to be consistent with equilibrium values. The technique will be useful in combinatorial materials design.


2018 ◽  
Vol 30 (5) ◽  
pp. 687-697 ◽  
Author(s):  
Sabereh Golabzaei ◽  
Ramin Khajavi ◽  
Heydar Ali Shayanfar ◽  
Mohammad Esmail Yazdanshenas ◽  
Nemat Talebi

Purpose There is a developing interest in flexible sensors, especially in the new and intelligent generation of textiles. The purpose of this paper is to fabricate a flexible capacitive sensor on a PET fabric and to investigate some affecting factor on its performance. Design/methodology/approach PET fabric, coated with graphite or with graphite/PEDOT:PSS, was applied as electrodes. Two types of electrospun nanoweb layers from polyamide and polyvinyl alcohol polymers were used as dielectrics. Some factors including electrode area, fabric conductivity, fabric roughness, dielectric thickness, dielectric insulation type and vertical pressure were considered as independent variables. The capacity of the sensor and its detection threshold considered as the outcome (response) variables. Control samples were fabricated by using aluminum plates and cellulosic layer as electrodes and dielectric, respectively. Findings Results showed that post-coating with PEDOT:PSS would improve the conductivity of electrodes up to 300 Ω in comparison with just graphite-coated samples. It was also found that either by improving the conductivity or increasing the area of electrode plates the sensitivity of sample would be increased in pressure stimulating tests. Originality/value The fabric sensor showed remarkable response toward pressure with a lower detection threshold of 30mN/cm2 (obtained capacity ~ 4×104 pF) in comparison with aluminum electrode sensors.


2021 ◽  
Vol MA2021-01 (60) ◽  
pp. 1603-1603
Author(s):  
Sajjad Janfaza ◽  
Seyedehhamideh Razavi ◽  
Arash Dalili ◽  
Mina Hoorfar

Author(s):  
M. van der Velden ◽  
J.W. Spronck ◽  
R.H. Munnig Schmidt ◽  
J. Wei ◽  
P.M. Sarro
Keyword(s):  

1993 ◽  
Vol 26 (3) ◽  
pp. 141-148 ◽  
Author(s):  
D.K. Bhattacharya ◽  
T. Jayakumar ◽  
V. Moorthy ◽  
S. Vaidyanathan ◽  
Baldev Raj

Sign in / Sign up

Export Citation Format

Share Document