Design of Gm-C low-pass filter with a low corner frequency

Author(s):  
Ren-Yi Lin ◽  
Chia-Ling Wei ◽  
Hung-Hsien Wu
1995 ◽  
Vol 269 (6) ◽  
pp. H2141-H2146 ◽  
Author(s):  
Y. Ikeda ◽  
M. Sugimachi ◽  
T. Yamasaki ◽  
O. Kawaguchi ◽  
T. Shishido ◽  
...  

Although the artificial cardiac pacemaker has contributed to the management of patients with serious arrhythmias, its rate-responsive function is not sufficient to provide physiological regulation of heart rate (HR). To achieve truly physiological rate response in any given patient, we propose a framework to develop a pacemaker directly regulated by sympathetic nerve activity (SNA). In eight anesthetized rabbits, we quantified the dynamic transduction characteristics from SNA to HR as a transfer function. We then characterized the decoding rule as an impulse response, that is the transfer characteristics in the time domain. The transfer function was approximated by a first-order, low-pass filter with lag time (corner frequency: 0.024 +/- 0.013 Hz, lag time: 0.98 +/- 0.09 s). Predicted HR correlated well with measured HR (r = 0.80-0.98). The standard error of the prediction relative to mean HR was only 1.2 +/- 0.7%, indicating that the prediction was reasonably accurate. Direct decoding of SNA to predict instantaneous HR is possible through this analysis. This framework should enable development of a neurally regulated artificial pacemaker.


2017 ◽  
Vol E100.C (10) ◽  
pp. 858-865 ◽  
Author(s):  
Yohei MORISHITA ◽  
Koichi MIZUNO ◽  
Junji SATO ◽  
Koji TAKINAMI ◽  
Kazuaki TAKAHASHI

2016 ◽  
Vol 15 (12) ◽  
pp. 2579-2586
Author(s):  
Adina Racasan ◽  
Calin Munteanu ◽  
Vasile Topa ◽  
Claudia Pacurar ◽  
Claudia Hebedean

Author(s):  
Nanan Chomnak ◽  
Siradanai Srisamranrungrueang ◽  
Natapong Wongprommoon
Keyword(s):  

Sensors ◽  
2021 ◽  
Vol 21 (13) ◽  
pp. 4305
Author(s):  
Takamasa Terada ◽  
Masahiro Toyoura ◽  
Takahide Sato ◽  
Xiaoyang Mao

In this work, we propose a fabric electrode with a special structure that can play the role of a noise reduction filter. Fabric electrodes made of the conductive fabric have been used for long-term ECG measurements because of their flexibility and non-invasiveness; however, due to the large impedance between the skin and the fabric electrodes, noise is easily introduced into the ECG signal. In contrast to conventional work, in which chip-type passive elements are glued to the electrode to reduce noise, the proposed electrode can obtain a noise-reduced ECG by changing the structure of fabric. Specifically, the proposed electrode was folded multiple times to form a capacitor with a capacitance of about 3 nF. It is combined with the skin-electrode impedance to form a low-pass filter. In the experiment, we made a prototype of the electrodes and measured ECG at rest and during EMG-induced exercise. As a result, the SNR values at rest and during exercise were improved about 12.02 and 10.29 , respectively, compared with the fabric electrode without special structure. In conclusion, we have shown that changing the fabric electrode structure effectively removes noise in ECG measurement.


Sign in / Sign up

Export Citation Format

Share Document