Impact of long-period line-edge roughness (LER) on accuracy in critical dimension (CD) measurement and a new guideline for cd metrology

Author(s):  
A. Ywiaguechi ◽  
H. Fukuda ◽  
H. Kawada ◽  
T. Iizura
Nanomaterials ◽  
2020 ◽  
Vol 10 (12) ◽  
pp. 2443
Author(s):  
Tommaso Giammaria ◽  
Ahmed Gharbi ◽  
Anne Paquet ◽  
Paul Nealey ◽  
Raluca Tiron

This work reports a novel, simple, and resist-free chemo-epitaxy process permitting the directed self-assembly (DSA) of lamella polystyrene-block-polymethylmethacrylate (PS-b-PMMA) block copolymers (BCPs) on a 300 mm wafer. 193i lithography is used to manufacture topographical guiding silicon oxide line/space patterns. The critical dimension (CD) of the silicon oxide line obtained can be easily trimmed by means of wet or dry etching: it allows a good control of the CD that permits finely tuning the guideline and the background dimensions. The chemical pattern that permits the DSA of the BCP is formed by a polystyrene (PS) guide and brush layers obtained with the grafting of the neutral layer polystyrene-random-polymethylmethacrylate (PS-r-PMMA). Moreover, data regarding the line edge roughness (LER) and line width roughness (LWR) are discussed with reference to the literature and to the stringent requirements of semiconductor technology.


2005 ◽  
Author(s):  
Atsuko Yamaguchi ◽  
Hiroshi Fukuda ◽  
Hiroki Kawada ◽  
Takashi Iizumi

Sensors ◽  
2021 ◽  
Vol 22 (1) ◽  
pp. 314
Author(s):  
Jan Thiesler ◽  
Thomas Ahbe ◽  
Rainer Tutsch ◽  
Gaoliang Dai

State of the art three-dimensional atomic force microscopes (3D-AFM) cannot measure three spatial dimensions separately from each other. A 3D-AFM-head with true 3D-probing capabilities is presented in this paper. It detects the so-called 3D-Nanoprobes CD-tip displacement with a differential interferometer and an optical lever. The 3D-Nanoprobe was specifically developed for tactile 3D-probing and is applied for critical dimension (CD) measurements. A calibrated 3D-Nanoprobe shows a selectivity ratio of 50:1 on average for each of the spatial directions x, y, and z. Typical stiffness values are kx = 1.722 ± 0.083 N/m, ky = 1.511 ± 0.034 N/m, and kz = 1.64 ± 0.16 N/m resulting in a quasi-isotropic ratio of the stiffness of 1.1:0.9:1.0 in x:y:z, respectively. The probing repeatability of the developed true 3D-AFM shows a standard deviation of 0.18 nm, 0.31 nm, and 0.83 nm for x, y, and z, respectively. Two CD-line samples type IVPS100-PTB, which were perpendicularly mounted to each other, were used to test the performance of the developed true 3D-AFM: repeatability, long-term stability, pitch, and line edge roughness and linewidth roughness (LER/LWR), showing promising results.


Sign in / Sign up

Export Citation Format

Share Document