Manipulating the Barrier Function of a Cell Monolayer Using a High-power Miniature Ultrasonic Transducer

Author(s):  
Mihnea V. Turcanu ◽  
Alexandru C. Moldovan ◽  
Maya Thanou ◽  
Inke Nathke ◽  
Sandy Cochran
2009 ◽  
Vol 1239 ◽  
Author(s):  
Bhavana Mohanraj ◽  
Nathan Schiele ◽  
Anne Hynes ◽  
Zijie Yan ◽  
David T. Corr ◽  
...  

AbstractElectric Cell-Impedance Sensing (ECIS) is a real-time transduction system that can be used to detect the presence of foreign particles or pathogens by measuring the changes in impedance or resistance of a cell monolayer grown on an electrode. Herein, we present the use of ECIS for the detection of the toxicity of silver nanoparticles on Madine Derby Canine Kidney (MDCK) epithelial cells as a function of changes in the cell confluence and barrier function of the cell monolayer. The barrier function is a measure of the number of tight junctions formed between confluent cells in a monolayer; tighter confluence leads to an increase in a barrier function and thus in the measured resistance. We were able to detect exposures as low as 1 μg of 20 nm silver nanoparticles per 105 cells within 2 hours; those exposures were quantified as a significant drop in impedance and a gradual decrease in the barrier function as compared to the controls. Future work would include the detection of protein toxins using impedance sensing as well as further analysis of the barrier function using fluorescent staining.


Biosensors ◽  
2018 ◽  
Vol 8 (4) ◽  
pp. 90 ◽  
Author(s):  
Andrea Gu ◽  
Dan Kho ◽  
Rebecca Johnson ◽  
E. Graham ◽  
Simon O’Carroll

Electric Cell-Substrate Impedance Sensing (ECIS) can produce reproducible wounding models by mechanically disrupting a cell monolayer. This study compared in vitro wound-healing using human cerebral microvascular endothelial cells (hCMVEC) with both single electrode (8W1E) and multiple electrodes (8W10E+) arrays. Measurements of hCMVEC migration and barrier functions were conducted, revealing variable levels of barrier disruption could be achieved by altering the duration and magnitude of the applied current. In all scenarios, the barrier (Rb) did not recover the strength observed prior to injury. Localization of junctional proteins following wounding were analyzed by immunocytochemistry. Following wounding, cell migration was generally faster on the 8W10E+ than the 8W1E array. Immunohistochemical analysis revealed non-viable cells remained on the 8W1E electrodes but not the 8W10E+ electrodes. However, viable cells partially remained on the 8W10E+ electrodes following wounding. In addition, the 8W10E+ electrodes demonstrated variation in cell loss across electrodes within the same well. This suggests the type of wounding is different on the two array types. However, our data show both arrays can be used to model incomplete barrier recovery and therefore both have potential for testing of drugs to improve endothelial barrier function. This is the first time that the possibility of using the 8W10E+ array as a wounding model is addressed. We highlight the differences in wounding produced between the two arrays, and can be used to study the underlying causes for impaired barrier function following CNS injuries.


2019 ◽  
Vol 35 (6) ◽  
pp. 87-90
Author(s):  
S.V. Nikulin ◽  
V.A. Petrov ◽  
D.A. Sakharov

The real-time monitoring of electric capacitance (impedance spectroscopy) allowed obtaining evidence that structures which look like intestinal villi can be formed during the cultivation under static conditions as well as during the cultivation in microfluidic chips. It was shown in this work via transcriptome analysis that the Hh signaling pathway is involved in the formation of villus-like structures in vitro, which was previously shown for their formation in vivo. impedance spectroscopy, intestine, villi, electric capacitance, Hh The study was funded by the Russian Science Foundation (Project 16-19-10597).


2017 ◽  
Vol 64 (11) ◽  
pp. 4636-4643 ◽  
Author(s):  
Shuai Na ◽  
Zhou Zheng ◽  
Albert I-Hsiang Chen ◽  
Lawrence L. P. Wong ◽  
Zhenhao Li ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document