DC-AC inverter using hysteresis current controller with a low pass filter for WECS

Author(s):  
Khalid H. Mohamed ◽  
Taib Bin Ibrahim ◽  
Nordin Saad
Author(s):  
Siti Hajar Yusoff ◽  
Nur Shahida Midi ◽  
Sheroz Khan ◽  
Majdee Tohtayong

<span>This work investigates the usage of Model Predictive Control (MPC) for a three phase conventional matrix converter with low pass filter at the input and output side. The conventional matrix converter has 3 input and 3 output which gives 27 switching state. From this design, a MPC is incorporate to control the output voltage and the input currents for all the phases. The design of the proposed controller is based on the input current controller and output voltage controller with load observer.  The proposed MPC using cost function will select the minimized switching state to be applied to next switching. This gives a sinusoidal output voltages and input currents. A simulation and experimental studies are presented to validate the proposed control scheme.</span>


2017 ◽  
Vol E100.C (10) ◽  
pp. 858-865 ◽  
Author(s):  
Yohei MORISHITA ◽  
Koichi MIZUNO ◽  
Junji SATO ◽  
Koji TAKINAMI ◽  
Kazuaki TAKAHASHI

2016 ◽  
Vol 15 (12) ◽  
pp. 2579-2586
Author(s):  
Adina Racasan ◽  
Calin Munteanu ◽  
Vasile Topa ◽  
Claudia Pacurar ◽  
Claudia Hebedean

Author(s):  
Nanan Chomnak ◽  
Siradanai Srisamranrungrueang ◽  
Natapong Wongprommoon
Keyword(s):  

Sensors ◽  
2021 ◽  
Vol 21 (13) ◽  
pp. 4305
Author(s):  
Takamasa Terada ◽  
Masahiro Toyoura ◽  
Takahide Sato ◽  
Xiaoyang Mao

In this work, we propose a fabric electrode with a special structure that can play the role of a noise reduction filter. Fabric electrodes made of the conductive fabric have been used for long-term ECG measurements because of their flexibility and non-invasiveness; however, due to the large impedance between the skin and the fabric electrodes, noise is easily introduced into the ECG signal. In contrast to conventional work, in which chip-type passive elements are glued to the electrode to reduce noise, the proposed electrode can obtain a noise-reduced ECG by changing the structure of fabric. Specifically, the proposed electrode was folded multiple times to form a capacitor with a capacitance of about 3 nF. It is combined with the skin-electrode impedance to form a low-pass filter. In the experiment, we made a prototype of the electrodes and measured ECG at rest and during EMG-induced exercise. As a result, the SNR values at rest and during exercise were improved about 12.02 and 10.29 , respectively, compared with the fabric electrode without special structure. In conclusion, we have shown that changing the fabric electrode structure effectively removes noise in ECG measurement.


Sign in / Sign up

Export Citation Format

Share Document