Design of automatic power consumption control system using smart grid — A review

Author(s):  
P. Sakthivel ◽  
S. Ganeshkumaran
Author(s):  
Anitha. A

Transformation to Smart Grid needs proper design of good communication and monitoring infrastructure for the Smart meters as well as understanding the power use pattern of the individual users for providing them uniform power supply as per the individual consumer’s requirement.In the proposed system, the meter monitors and calculates the power and if the consumer exceeds the prescribed load limit it alarms. In case the consumer does not reduce his load meter automatically it cuts off the particular loads in consumer connection. GSM communications network are used to transfer electricity consumed data to the consumer as per programmed in the Arduino kit.


2016 ◽  
Vol 62 (4) ◽  
pp. 362-370 ◽  
Author(s):  
Qiong Tang ◽  
Ángel M. Groba ◽  
Eduardo Juarez ◽  
Cesar Sanz ◽  
Fernando Pescador

Sensors ◽  
2020 ◽  
Vol 20 (13) ◽  
pp. 3635 ◽  
Author(s):  
Guoming Zhang ◽  
Xiaoyu Ji ◽  
Yanjie Li ◽  
Wenyuan Xu

As a critical component in the smart grid, the Distribution Terminal Unit (DTU) dynamically adjusts the running status of the entire smart grid based on the collected electrical parameters to ensure the safe and stable operation of the smart grid. However, as a real-time embedded device, DTU has not only resource constraints but also specific requirements on real-time performance, thus, the traditional anomaly detection method cannot be deployed. To detect the tamper of the program running on DTU, we proposed a power-based non-intrusive condition monitoring method that collects and analyzes the power consumption of DTU using power sensors and machine learning (ML) techniques, the feasibility of this approach is that the power consumption is closely related to the executing code in CPUs, that is when the execution code is tampered with, the power consumption changes accordingly. To validate this idea, we set up a testbed based on DTU and simulated four types of imperceptible attacks that change the code running in ARM and DSP processors, respectively. We generate representative features and select lightweight ML algorithms to detect these attacks. We finally implemented the detection system on the windows and ubuntu platform and validated its effectiveness. The results show that the detection accuracy is up to 99.98% in a non-intrusive and lightweight way.


2013 ◽  
Vol 303-306 ◽  
pp. 1657-1660
Author(s):  
Zhi Guang Zhang ◽  
Wei Hu ◽  
Xiao Qiong Li ◽  
Xue Fei Lv ◽  
Min Ping Zhang ◽  
...  

For the precision rotor position control of stream selector, a control system based on direct current motor (DC motor) has been constructed. The DC motor, with a high-precision incremental encoder used as the driving force, was assembled with the stream selector rotor through a shaft coupling. Following the motor rotation, the encoder generated two-channel quadrature pulses and one channel index pulses. An ultralow-power consumption microcontroller (msp430f2232) received theses pulses and calculated them. The position of the slot was determined by the number of pulses counted from the index pulse. Operator can set and monitored the slot positions of five stream selectors simultaneously through the program which was written with LabVIEW on the host computer. This module featured high reliability and low power consumption compared with the one driven by step motor. Beyond that, it was much smaller and lighter.


Sign in / Sign up

Export Citation Format

Share Document