Hybrid Frequency-Selective Rasorber with Low-Frequency Diffusion and High-Frequency Absorption

Author(s):  
Lin Zhou ◽  
Zhongxiang Shen
Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1521
Author(s):  
Jihoon Lee ◽  
Seungwook Yoon ◽  
Euiseok Hwang

With the development of the internet of things (IoT), the power grid has become intelligent using massive IoT sensors, such as smart meters. Generally, installed smart meters can collect large amounts of data to improve grid visibility and situational awareness. However, the limited storage and communication capacities can restrain their infrastructure in the IoT environment. To alleviate these problems, efficient and various compression techniques are required. Deep learning-based compression techniques such as auto-encoders (AEs) have recently been deployed for this purpose. However, the compression performance of the existing models can be limited when the spectral properties of high-frequency sampled power data are widely varying over time. This paper proposes an AE compression model, based on a frequency selection method, which improves the reconstruction quality while maintaining the compression ratio (CR). For efficient data compression, the proposed method selectively applies customized compression models, depending on the spectral properties of the corresponding time windows. The framework of the proposed method involves two primary steps: (i) division of the power data into a series of time windows with specified spectral properties (high-frequency, medium-frequency, and low-frequency dominance) and (ii) separate training and selective application of the AE models, which prepares them for the power data compression that best suits the characteristics of each frequency. In simulations on the Dutch residential energy dataset, the frequency-selective AE model shows significantly higher reconstruction performance than the existing model with the same CR. In addition, the proposed model reduces the computational complexity involved in the analysis of the learning process.


Author(s):  
G. Y. Fan ◽  
J. M. Cowley

It is well known that the structure information on the specimen is not always faithfully transferred through the electron microscope. Firstly, the spatial frequency spectrum is modulated by the transfer function (TF) at the focal plane. Secondly, the spectrum suffers high frequency cut-off by the aperture (or effectively damping terms such as chromatic aberration). While these do not have essential effect on imaging crystal periodicity as long as the low order Bragg spots are inside the aperture, although the contrast may be reversed, they may change the appearance of images of amorphous materials completely. Because the spectrum of amorphous materials is continuous, modulation of it emphasizes some components while weakening others. Especially the cut-off of high frequency components, which contribute to amorphous image just as strongly as low frequency components can have a fundamental effect. This can be illustrated through computer simulation. Imaging of a whitenoise object with an electron microscope without TF limitation gives Fig. 1a, which is obtained by Fourier transformation of a constant amplitude combined with random phases generated by computer.


Author(s):  
M. T. Postek ◽  
A. E. Vladar

Fully automated or semi-automated scanning electron microscopes (SEM) are now commonly used in semiconductor production and other forms of manufacturing. The industry requires that an automated instrument must be routinely capable of 5 nm resolution (or better) at 1.0 kV accelerating voltage for the measurement of nominal 0.25-0.35 micrometer semiconductor critical dimensions. Testing and proving that the instrument is performing at this level on a day-by-day basis is an industry need and concern which has been the object of a study at NIST and the fundamentals and results are discussed in this paper.In scanning electron microscopy, two of the most important instrument parameters are the size and shape of the primary electron beam and any image taken in a scanning electron microscope is the result of the sample and electron probe interaction. The low frequency changes in the video signal, collected from the sample, contains information about the larger features and the high frequency changes carry information of finer details. The sharper the image, the larger the number of high frequency components making up that image. Fast Fourier Transform (FFT) analysis of an SEM image can be employed to provide qualitiative and ultimately quantitative information regarding the SEM image quality.


1992 ◽  
Vol 1 (4) ◽  
pp. 52-55 ◽  
Author(s):  
Gail L. MacLean ◽  
Andrew Stuart ◽  
Robert Stenstrom

Differences in real ear sound pressure levels (SPLs) with three portable stereo system (PSS) earphones (supraaural [Sony Model MDR-44], semiaural [Sony Model MDR-A15L], and insert [Sony Model MDR-E225]) were investigated. Twelve adult men served as subjects. Frequency response, high frequency average (HFA) output, peak output, peak output frequency, and overall RMS output for each PSS earphone were obtained with a probe tube microphone system (Fonix 6500 Hearing Aid Test System). Results indicated a significant difference in mean RMS outputs with nonsignificant differences in mean HFA outputs, peak outputs, and peak output frequencies among PSS earphones. Differences in mean overall RMS outputs were attributed to differences in low-frequency effects that were observed among the frequency responses of the three PSS earphones. It is suggested that one cannot assume equivalent real ear SPLs, with equivalent inputs, among different styles of PSS earphones.


1971 ◽  
Vol 36 (4) ◽  
pp. 527-537 ◽  
Author(s):  
Norman P. Erber

Two types of special hearing aid have been developed recently to improve the reception of speech by profoundly deaf children. In a different way, each special system provides greater low-frequency acoustic stimulation to deaf ears than does a conventional hearing aid. One of the devices extends the low-frequency limit of amplification; the other shifts high-frequency energy to a lower frequency range. In general, previous evaluations of these special hearing aids have obtained inconsistent or inconclusive results. This paper reviews most of the published research on the use of special hearing aids by deaf children, summarizes several unpublished studies, and suggests a set of guidelines for future evaluations of special and conventional amplification systems.


2016 ◽  
Vol 17 (1) ◽  
pp. 66
Author(s):  
Maria Lina Silva Leite
Keyword(s):  

O objetivo deste estudo foi avaliar os efeitos do Método Pilates sobre a variabilidade da frequência cardíaca, na flexibilidade e nas variáveis antropométricas em indivíduos sedentários. O presente estudo contou com 14 voluntárias do sexo feminino, na faixa etária entre 40 e 55 anos, que realizaram 20 sessões de exercícios do Método Pilates, duas vezes por semana, com duração de 45 minutos cada sessão, dividida em três fases: repouso, exercício e recuperação. As variáveis estudadas foram: os dados antropométricos, flexibilidade avaliada utilizando o teste de sentar-e-alcançar com o Banco de Wells, e intervalos R-R usando um cardiotacômetro. O processamento dos sinais da frequência cardíaca foi efetuado em ambiente MatLab 6.1®, utilizando a TWC. Os dados coletados foram submetidos ao teste de normalidade de Shapiro Wilk e foi utilizado o teste de Wilcoxon e Anova One Way (α = 0,05). Nos resultados, observou-se que não houve diferenças significativas entre os valores antropométricos e de frequência cardíaca, porém houve aumento da flexibilidade com o treinamento. Comparando a primeira e a vigésima sessão com relação aos parâmetros low frequency (LF), high frequency (HF), e relação LF/HF, não houve diferença na fase de repouso e foram constatadas diferenças significativas de LF (p = 0,04) e HF (p = 0,04) na fase de exercício e diferença significativa de LF/HF (p = 0,05) na fase de recuperação. Comparando os parâmetros nos períodos de repouso, exercícios e recuperação durante a primeira sessão e durante a vigésima sessão, não houve diferença significativa nos parâmetros LF, HF e LF/HF. Pode-se concluir que, em relação à flexibilidade, foi observada uma melhora significativa, enquanto a análise da frequência cardíaca caracterizou a intensidade do exercício de 50% da capacidade funcional das voluntárias. Em relação aos parâmetros LF, HF e LF/HF foram observados um aumento da variabilidade da frequência cardíaca, provavelmente produto da atividade do Método Pilates. A Transformada Wavelet (TWC) mostrou-se um Método adequado para as análises da variabilidade da frequência cardíaca.Palavras-chave: frequência cardíaca, Transformada Wavelet, Pilates.


Sign in / Sign up

Export Citation Format

Share Document