Characterization of a 3.3-kV Si-SiC Hybrid Power Module in Half-Bridge Topology for Traction Inverter Application

2020 ◽  
Vol 35 (12) ◽  
pp. 13429-13440 ◽  
Author(s):  
Daohui Li ◽  
Xiang Li ◽  
Guiqin Chang ◽  
Fang Qi ◽  
Matthew Packwood ◽  
...  
Keyword(s):  
2018 ◽  
Vol 924 ◽  
pp. 854-857
Author(s):  
Ming Hung Weng ◽  
Muhammad I. Idris ◽  
S. Wright ◽  
David T. Clark ◽  
R.A.R. Young ◽  
...  

A high-temperature silicon carbide power module using CMOS gate drive technology and discrete power devices is presented. The power module was aged at 200V and 300 °C for 3,000 hours in a long-term reliability test. After the initial increase, the variation in the rise time of the module is 27% (49.63ns@1,000h compared to 63.1ns@3,000h), whilst the fall time increases by 54.3% (62.92ns@1,000h compared to 97.1ns@3,000h). The unique assembly enables the integrated circuits of CMOS logic with passive circuit elements capable of operation at temperatures of 300°C and beyond.


IEEE Access ◽  
2020 ◽  
Vol 8 ◽  
pp. 182600-182609
Author(s):  
Xiang Li ◽  
Daohui Li ◽  
Guiqin Chang ◽  
Matthew Packwood ◽  
Daniel Pottage ◽  
...  

Author(s):  
Shiladitya Chakravorty ◽  
Bahgat Sammakia ◽  
Varaprasad Calmidi

Improved performance of semiconductor devices in recent years has resulted in consequent increase in power dissipation. Hence thermal characterization of components becomes important from an overall thermal design perspective of the system. This study looks at a high performance non-isolated point of load power module (a DC to DC converter) meant for advanced computing and server applications. Thermal characteristics of the module were experimentally analyzed by placing the power module on a bare test board (with no insulation) inside a wind tunnel with thermocouples attached to it. There were three devices on this module that dissipate power. There were two FETs (Field Effect Transistors) and an inductor which can be considered as sources. The consolidated power dissipation from the module was calculated by measuring the input voltage and input current while keeping the output voltage and current constant. Temperatures at various points on the module and the test card were recorded for different air flow velocities and overall power dissipation. Subsequently this set up was numerically analyzed using a commercially available computational fluid dynamics (CFD) code with the objective of comparing the results with experimental data previously obtained.


2010 ◽  
Vol 7 (14) ◽  
pp. 1008-1013 ◽  
Author(s):  
Tsuyoshi Funaki ◽  
Hiroyasu Inoue ◽  
Masashi Sasagawa ◽  
Takashi Nakamura

Sign in / Sign up

Export Citation Format

Share Document