scholarly journals Intracavitary electrocardiography for femorally inserted central catheter tip location in adult patients

Author(s):  
YingFang Duan ◽  
XiaoYan Hu ◽  
YuXin Zhu ◽  
Xi Zhao ◽  
XinXin Yin ◽  
...  
2005 ◽  
Vol 53 (1) ◽  
pp. S127.1-S127
Author(s):  
P. Fliman ◽  
R. deRegnier ◽  
M. DeUngria ◽  
R. Shore ◽  
R. Steinhorn

2016 ◽  
Vol 15 (2) ◽  
Author(s):  
Keline Soraya Santana Nobre ◽  
Maria Vera Lúcia Moreira Leitão Cardoso ◽  
Juliana Lopes Teixeira ◽  
Márcia Maria Coelho Oliveira Lopes ◽  
Fernanda Cavalcante Fontenele

Aim:  analyze  the  use  of  peripherally  inserted  central  catheter  in terms of the aspects of technique, positioning and maintenance, as well as the influence on the number of venous dissections in hospitalized infants in a neonatal unit. Method: descriptive,  retrospective,  quantitative  study,  in  reference  maternity  unit  of  a  city  in northeastern  Brazil.  Sample  composed  of  1,599  peripherally  inserted  central  catheter insertions in 1,204 infants during the years 2006 to 2013. Instruments were used that recorded  aspects  of  the  insertion  of  peripherally  inserted  central  catheter  and  venous dissection.  Results:  most  babies  were  premature,  of  low  birth  weight  and  male.  The veins  of  the  cubital  region  were  the  most  punctured  with  insertion  success  until  the fourth  puncture.  The  central  positioning  of  the  catheter  tip predominated,  with  a permanency  time  between  11  and  20  days,  removing  it  at  the  end  of  the  treatment. Over  the  years,  the  number  of  venous  dissections  was  inversely  proportional  to  the insertion  of  peripherally  inserted  central  catheter.  Conclusion:  this  transvenous  device was  shown  to  be  important  for  the  treatment  of  hospitalized  newborns,  favoring reduction of venous dissections.


2022 ◽  
Vol 75 (2) ◽  
Author(s):  
Andreia Tomazoni ◽  
Patrícia Kuerten Rocha ◽  
Mavilde da Luz Gonçalves Pedreira ◽  
Elisa da Conceição Rodrigues ◽  
Bruna Figueiredo Manzo ◽  
...  

ABSTRACT Objective: to analyze the results of insertion procedures of Peripherally Inserted Central Catheters in newborns using two measurement methods. Methods: this is a randomized clinical trial, presenting descriptive and exploratory results of variables. It was held at a Neonatal Intensive Care Unit. Data were collected between September 2018 and 2019. The sample analyzed was 88 catheter insertion procedures, distributed in two groups. Study approved by an Institutional Review Board and obtained registration in the country and abroad. Descriptive analysis and logistic regression of data. Results: modified measurement obtained a significant difference for the central catheter tip location. Elective removals and adverse events were not significant between groups; however, poor positioning was related to adverse events. Conclusions: between the two methods analyzed, the modified measurement obtained better results in the proper catheter tip positioning and, consequently, less risk to patients.


2020 ◽  
Vol 21 (5) ◽  
pp. 732-737
Author(s):  
Chunli Liu ◽  
Dingbiao Jiang ◽  
Tao Jin ◽  
Chuanyin Chen ◽  
Ruchun Shi ◽  
...  

Purpose: To evaluate the influence of body posture change on the peripherally inserted central catheter tip position in Chinese cancer patients. Methods: A prospective observational trial was conducted in a tertiary cancer hospital from August to September 2018. After the insertion of peripherally inserted central catheter, chest X-ray films were taken to check the catheter tip in the upright and supine positions, respectively. The distance from the carina to the catheter tip was separately measured on both chest films by nurses. The primary study outcome was the distance and direction of the catheter tip movement. The secondary study outcome was to analyze the influence factors on the catheter tip movement. The third study outcome was to observe the related adverse events caused by the catheter tip movement. Results: A total of 79 patients were included, the results showed that 61 moved cephalad, 14 moved caudally, and 4 did not move with body change from the supine to the upright position. When moved cephalad, the mean distance was 19.34 ± 11.95 mm; when moved caudally, the mean distance was –15.83 ± 8.97 mm. The difference between the two positions was statistically significant ( p < 0.001). There was also a statistically significant difference between catheter tip movement direction and body mass index ( p = 0.009) and height ( p = 0.015). Two patients developed arrhythmias; no cardiac tamponade was found due to body posture change. Conclusion: The results of this work implied that the tips of the catheter tend to shift toward the cephalad with body change from the supine to the upright position. A study involving a larger sample size is needed to find more information in the future.


Open Medicine ◽  
2017 ◽  
Vol 12 (1) ◽  
pp. 125-130 ◽  
Author(s):  
Lian-juan Zhou ◽  
Hong-zhen Xu ◽  
Mei-fang Xu ◽  
Yan Hu ◽  
Xiao-Fang Lou

AbstractObjectiveTo explore the clinical application of the intracavitary electrocardiogram (IC-ECG) guided Peripherally Inserted Central Catheter (PICC) tip placement among neonates.Backgroundthe ECGs of neonates are difficult to perform and their wave shapes are of doubtful accuracy due to various interfering factorsMethod115 neonates were admitted to perform PICC guided by IC-ECG. Logistic regression was performed to analyze all possible influencing factors of the accuracy from the tip placement. The puncture site of the PICC, gestational age, height, weight, basal P/R amplitude and positioning P/R amplitude might be related to the accuracy of IC-ECG location.ResultThe accuracy in the lower extremity was higher than that in the upper extremity. Multivariate logistic regression analysis showed that the weight (Odds Ratio (OR)=1.93, 95%Confidence Interval(CI):1.06-3.50) and positioning P/R amplitude (OR=32.33, 95%CI: 2.02-517.41) are statistically significant risks to the accuracy PICC tip placement.ConclusionsPossible methods to improve the accuracy might be Catheterizing through lower extremity, keeping the neonates calm, enhancing the electrocardiogram signal and strengthening technical training. Therefore it is practical to perfrom a tip placement by the dynamic change in the P waves from an electrocardiogram (ECG) guided PICC among neonates and as reliable as using X-rays.


2019 ◽  
Vol 21 (2) ◽  
pp. 259-264 ◽  
Author(s):  
Mark D Weber ◽  
Adam S Himebauch ◽  
Thomas Conlon

Introduction: Peripherally inserted central catheter tip migration is an infrequent event that occurs in neonatal, pediatric, and adult patients. We discuss a novel technique of utilizing intracavitary electrocardiogram to help confirm proper peripherally inserted central catheter tip repositioning, thereby reducing the need for serial radiographs. Case presentation: A case series of four patients will be discussed. The first three patients had peripherally inserted central catheter tips that were initially appropriately positioned but had later peripherally inserted central catheter tip migration. The use of intracavitary electrocardiogram was able to confirm the appropriate repositioning of the peripherally inserted central catheters without the need for serial radiographs. The fourth patient had several central lines in place, which led to difficulty in identifying the peripherally inserted central catheter tip location. The use of intracavitary electrocardiogram confirmed proper positioning of his peripherally inserted central catheter tip when standard radiographs could not provide clarity. Discussion: Several techniques have been published on methods to reposition a migrated peripherally inserted central catheter tip back to the superior vena cava/right atrial junction. These repositioning techniques often require fluoroscopic guidance or a confirmatory radiograph to assess the appropriate peripherally inserted central catheter tip location. At times, several radiographs may be required before the tip is successfully repositioned. This novel application of intracavitary electrocardiogram can help to minimize radiographs when peripherally inserted central catheter tip repositioning is required.


2020 ◽  
Vol 48 (1) ◽  
pp. 486-486
Author(s):  
Ryan Meinen ◽  
Adam Bauer ◽  
Kelly Devous ◽  
Awni Al-Subu ◽  
Eileen Cowan

Sign in / Sign up

Export Citation Format

Share Document