Performance analysis of newly developed point-of-care hemoglobinometer (TrueHb) against an automated hematology analyzer (Sysmex XT 1800i) in terms of precision in hemoglobin measurement

2014 ◽  
Vol 37 (4) ◽  
pp. 483-485 ◽  
Author(s):  
A. Srivastava ◽  
V. Koul ◽  
S. N. Dwivedi ◽  
A. D. Upadhyaya ◽  
A. Ahuja ◽  
...  

Anemia is a major health concern in India since many decades and is continue to rise. Therefore, Hemoglobin measurement is performed in various Pathology labs, Hospitals, Blood Banks etc. to detect Technology. Different method are used for Hemoglobin measurement like Automated Hematology Analyzer, copper sulphate gravimetric method, Hemoglobin colour scale, HICN method, point of care Hemoglobin meter etc.


2018 ◽  
Vol 42 (5) ◽  
pp. 189-193
Author(s):  
Tevfik Honca ◽  
Mehtap Honca

AbstractBackgroundThe aim of the present study was to compare hemoglobin (Hb) levels determined by point-of-care testing (POCT) HemoCue® and arterial blood gas analyzer using an automated hematology analyzer in critically ill geriatric patients.MethodsForty geriatric patients requiring intensive care treatment were included in the study. Arterial blood sample was analyzed using HemoCue® (HemoCue®; Hb 201+, Angelholm, Sweden) (HbHemoCueArterial), blood gas analyzer (Techno Medica, Gastat1800 series, Japan) (HbBGA) and an automated hematology analyzer (Cell Dyne 3700 System, Abbott Laboratories, USA) (HbLab) as a reference method. Capillary blood measurements were performed (HbHemoCueCapillary) using HemoCue® at bedside. Bland-Altman analysis was applied to the results.ResultsWe found a positive correlation between the Hb measurements of HemoCueCapillary, HemoCueArterial and automated hematology analyzer (r-values were 0.799 and 0.922, respectively) and p<0.001. There was also a positive correlation between the Hb measurements of blood gas analyzer and automated hematology analyzer (r = 0.878) and p<0.001. The bias and limits of agreement were 0.32 and −2.5±3.14 g/dL for the HbHemoCueCapillary, 0.64 and −1.03±2.31 g/dL for the HbHemoCueArterial and −1.2 and −4.45±2.05 g/dL for the HbBGA. Inotropic agent administration did not affect the Hb values in all groups.ConclusionsBoth HemoCueCapillary and HemoCueArterial are sufficiently accurate and correlated with automated hematology analyzer in geriatric critically ill patients if used correctly. In terms of Hb levels, arterial and capillary blood sample measurements with HemoCue® provided more clinically acceptable accuracy than blood gas analysis system.


PLoS ONE ◽  
2020 ◽  
Vol 15 (10) ◽  
pp. e0239931
Author(s):  
Stefan A. Nass ◽  
Ilias Hossain ◽  
Chilel Sanyang ◽  
Bakary Baldeh ◽  
Dora I. A. Pereira

Author(s):  
Gomathi Ramaswamy ◽  
Kashish Vohra ◽  
Kapil Yadav ◽  
Ravneet Kaur ◽  
Tripti Rai ◽  
...  

Abstract Introduction Globally around 47.4% of children and in India, 58% of children aged 6–59 months are anemic. Diagnosis of anemia in children using accurate technologies and providing adequate treatment is essential to reduce the burden of anemia. Point-of-care testing (POCT) devices is a potential option for estimation of hemoglobin in peripheral and field settings were the hematology analyzer and laboratory services are not available. Objectives To access the validity of the POCTs (invasive and non-invasive devices) for estimation of hemoglobin among children aged 6–59 months compared with hematology analyzer. Methods The study participants were enrolled from the pediatric outpatient department in Haryana, India, from November 2019 to January 2020. Hemoglobin levels of the study participants were estimated in Sahli’s hemoglobinometer and invasive digital hemoglobinometers (DHs) using capillary blood samples. Hemoglobin levels in non-invasive DH were assessed from the finger/toe of the children. Hemoglobin levels measured in POCTs were compared against the venous blood hemoglobin estimated in the hematology analyzer. Results A total of 120 children were enrolled. The mean (SD) of hemoglobin (g/dl) estimated in auto-analyzer was 9.4 (1.8), Sahli’s hemoglobinometer was 9.2 (1.9), invasive DH was 9.7 (1.9), and non-invasive DH was 11.9 (1.5). Sahli’s hemoglobinometer (95.5%) and invasive DH (92.2%) had high sensitivity for the diagnosis of anemia compared with non-invasive DH (24.4%). In contrast, non-invasive DH had higher specificity (96.7%) compared with invasive DH (83.3%) and Sahli’s hemoglobinometer (70%). Invasive DH took the least time (2–3 min) for estimation of hemoglobin per participant, followed by Sahli’s (4–5 min) and non-invasive DH (5–7 min). Conclusion All three POCT devices used in this study are reasonable and feasible for estimating hemoglobin in under-5 children. Invasive DHs are potential POCT devices for diagnosis of anemia among under-5 children, while Sahli’s can be considered as a possible option, where trained and skilled technicians are available. Further research and development are required in non-invasive DH to improve accuracy. Lay summary In India, anemia is a serious public health problem, where 58% of the children aged 6–59 months are anemic. Point-of-care testing (POCT) using digital hemoglobinometers (DHs) has been recommended as one of the key interventions by the Anemia Mukt Bharat program since 2018 in India. These POCT devices are easy to use, less invasive, can be carried to field, require minimal training and results are available immediately. Therefore this study assessed the validity of POCT devices—invasive DH, non-invasive DH and Sahli’s hemoglobinometer among 6–59 months children in facility setting compared with the gold standard hematology analyzer. A total of 120 children under 6–59 months of age were enrolled from the pediatric outpatient department in Haryana, India, from November 2019 to January 2020. The (mean hemoglobin in g/dl) invasive (9.7) and non-invasive DH (11.9) overestimated hemoglobin value, while Sahli’s (9.2) underestimated hemoglobin compared with hematology analyzer (9.4). Invasive DH (92.2%) and Sahli’s hemoglobinometer (95.5%) reported high ability to correctly identify those with anemia compared with non-invasive DH (24.4%). In contrast, non-invasive DH (96.73%) had higher ability to correctly identify those without the anemia compared with invasive DH (83.3%) and Sahli’s (70%).


2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Said Incir ◽  
Kerim Erhan Palaoglu

AbstractObjectivesWe performed a verification study of the Sysmex XN-3100 hematology analyzer in comparison with the XE-2100 according to the guidelines of the Clinical and Laboratory Standards Institute (CLSI) and the International Council for Standardization in Hematology (ICSH).Materials and methodsBlood samples and quality control materials were used for precision. For comparison, we used the current XE-2100 as the comparative method and analyzed 540 blood samples. The Passing-Bablok and Bland-Altman tests were performed according to the CLSI EP09-A3 and a carryover study was performed according to the CLSI H26-A2 guidelines. The flagging performance of the two analyzers was compared, using two experienced laboratory technicians as the reference method.ResultsThe Sysmex XN-3100 demonstrated high levels of precision for most parameters. For the comparison analysis, all parameters, except for MCHC, monocytes and basophils were within the systematic error limits of desirable biological variability criterion (SeDBV). The carryover was less than 0.4% for all parameters. The flagging performance of the XN-3100 was satisfactory and the overall efficiency was high.ConclusionsThe XN-3100 not only showed a strong correlation and agreement with the XE-2100 but also displayed a comparable analytical sensitivity, and increased specificity, which may result in an improved turnaround time and throughpu.


2012 ◽  
Vol 27 (5) ◽  
pp. 302-303
Author(s):  
P. Nguyen ◽  
P. Vancles ◽  
L. Rozen ◽  
D. Noubouossie ◽  
A. Demulder