Comparative evaluation of chromogenic agar CM1046 and mFC agar for detection of E. coli and thermotolerant coliform bacteria from water samples

2011 ◽  
Vol 53 (2) ◽  
pp. 155-160 ◽  
Author(s):  
T.D. Wohlsen
2021 ◽  
Author(s):  
Mirjana Grujović ◽  
◽  
Katarina Mladenović ◽  
Zoran Simić ◽  
Simona Đuretanović

This research aimed to investigate the quality of drinking water from the rural area of village Pajsijević (Šumadija, central Serbia). The water is consumed as raw since it is not purified or chlorinated before consumption. The water was collected at three sampling points – in the spring of Kotlenik Mountain stream (W1 sample), in the local reservoir (W2 sample), and from the tap (W3 sample). Also, the sediment samples (soil and sand) were analyzed, too. The health risks related to the presence and concentration of some major and trace elements (Ca, Cr, Cu, Fe, Mg, Mn, Ni, Zn) and N, NO, NN3, NH4, P, P2O5, and PO4 were evaluated. Additionally, the presence and the number of total coliform bacteria and Escherichia coli (as an indicator of fecal contamination) were evaluated. The concentrations of analyzed major and trace elements in all water samples were below those at which toxic effects may occur. The exception was the concentrations of Fe (2.02 – 2012 mg/L), which were higher than is allowed. The origin of Fe in water is from sediment (soil and sand), which also showed high content of Fe (3006.0 mg/g and 2229.9 mg/g, respectively). The results of the Colorimetric test indicated the presence of coliform bacteria as well as the presence of E. coli in all water samples. Further research needs to include characterization of isolated coliform bacteria and serological investigation of E. coli strains in order to evaluate the risks of consumption related to waterborne illness.


Jurnal BIOMA ◽  
2017 ◽  
Vol 11 (1) ◽  
pp. 73
Author(s):  
Rezki Rachmawati ◽  
Muzajjanah Muzajjanah ◽  
Yoswita Rustam

Refill Water Depot is currently more widely circulated and used as an alternative drinking water supply by the public. However the still unclear about the quality of the drinking water refill generated primarily of biological content. Parameters of biological contamination in drinking water caused by the Escherichia coli and coliform bacterium. This study aims to identify E. coli and coliforms in drinking water refill. Refill drinking water samples obtained from 16 drinking water refill from Jagakarsa subdsitrict. The method used is descriptive. Refill drinking water samples was taken and tested in the MPN (Most Probable Number) method and then to be tested in identification of E. coli. The results of testing the drinking water refill obtained 15 samples positive for coliform bacteria. Samples were positive for E. coli bacteria that sample B.1 and F.2.


2021 ◽  
Vol 10 (1) ◽  
pp. 23
Author(s):  
Muhammad Rayhan Braja Gitawama ◽  
Netti Suharti ◽  
Nora Harminarti

The National Food and Drug Agency has controlled the refill drinking water in drinking water depots and also controlled food at school canteens ranging from elementary, junior high, to high school, but the National Food and Drug Agency never do food quality controlling in canteens at universities. Objectives: To identified the contamination by coliform and E. coli bacteria in drinking water at Andalas University canteen. Methods: This research was descriptive to identify coliform bacteria on  15 drinking water at the Andalas University faculty canteens.  Samples were taken directly using a sterile bottle, while data analysis using Most Probable Number  (MPN)  tables 5-1-1 and the presence of E. coli bacteria colonies from drinking water samples. Results: 9 of 15 water samples were contaminated by coliform bacteria with the highest MPN index of 240/100 ml that was found in 2 samples. From 9 samples containing coliform bacteria, all of them were found to contain E. coli bacteria. Conclusion: Most of the samples were contaminated by coliform and E. coli bacteria. Drinking water served using a kettle was more contaminated than drinking water served using gallons.Keywords: Coliform, Escherichia coli, MPN


1997 ◽  
Vol 35 (11-12) ◽  
pp. 419-422
Author(s):  
G. McFeters ◽  
M. Pickett ◽  
S. Broadaway ◽  
B. Pyle

This study compared a chromogenic and fluorogenic substrate based medium, Colisure, with the conventional fermentation based medium, lauryl tryptose broth (LTB), for the recovery of chlorine-injured and non-injured coliforms and E. coli. Mixed natural populations of coliforms from sewage, with and without chlorine exposure, and untreated surface water samples were examined following a USEPA established procedure. Colisure and LTB were examined after 20, 24, 28 and 48h incubation and reactions verified. There were slight increases in positive reactions over time with unchlorinated samples, for which the two media gave similar kinetic patterns. The increases over time with chlorinated samples were much greater than with unchlorinated samples. LTB gave significantly lower total positive responses and had a more pronounced lag period than did Colisure. Total coliform bacteria from surface water samples gave somewhat different reactions with more of an increase with time. Colisure recovered comparable or higher numbers of total coliforms and E. coli in 20–28h than LTB after 48h. These results confirm that Colisure gives improved recovery of chlorine-injured total coliforms and E. coli under conditions simulating treated drinking and source water, resulting in a more realistic estimate of the actual population of indicator bacteria in public water supplies.


2012 ◽  
Vol 66 (12) ◽  
pp. 2674-2681 ◽  
Author(s):  
Selpha Opisa ◽  
Maurice R. Odiere ◽  
Walter G. Z. O. Jura ◽  
Diana M. S. Karanja ◽  
Pauline N. M. Mwinzi

High levels of environmental contamination, often associated with improper waste and excreta management, are widespread among informal settlements within urban areas in developing countries. We determined the level of faecal contamination in domestic water sources and evaluated the potential contribution of these water sources to intestinal helminthiases in seven informal settlements of Kisumu City, western Kenya. Membrane filtration technique was used for enumeration of total and faecal (Escherichia coli) coliform bacteria in water samples collected from dams, rivers, springs and wells. Out of the 80 water sources sampled, 76 (95%) were highly contaminated with E coli. All water samples from unprotected wells (26) and 92.6% of samples from protected wells (25) were positive for E. coli. The highest and lowest E. coli densities were observed in samples from dams (3,800 ± 1,807 coliforms per 100 ml) and boreholes (419 ± 223 coliforms per 100 ml), respectively (p = 0.0321). Distance from pit latrines was negatively associated with E. coli coliform density for wells (r = −0.34, n = 53, p = 0.0142). Untreated well-water may not be suitable for human consumption, and its continued use constitutes a major health risk for the inhabitants of these informal settlements.


2011 ◽  
Vol 64 (7) ◽  
pp. 1435-1442 ◽  
Author(s):  
Michael Hügler ◽  
Karin Böckle ◽  
Ingrid Eberhagen ◽  
Karin Thelen ◽  
Claudia Beimfohr ◽  
...  

Monitoring of microbiological contaminants in water supplies requires fast and sensitive methods for the specific detection of indicator organisms or pathogens. We developed a protocol for the simultaneous detection of E. coli and coliform bacteria based on the Fluorescence in situ Hybridization (FISH) technology. This protocol consists of two approaches. The first allows the direct detection of single E. coli and coliform bacterial cells on the filter membranes. The second approach includes incubation of the filter membranes on a nutrient agar plate and subsequent detection of the grown micro-colonies. Both approaches were validated using drinking water samples spiked with pure cultures and naturally contaminated water samples. The effects of heat, chlorine and UV disinfection were also investigated. The micro-colony approach yielded very good results for all samples and conditions tested, and thus can be thoroughly recommended for usage as an alternative method to detect E. coli and coliform bacteria in water samples. However, during this study, some limitations became visible for the single cell approach. The method cannot be applied for water samples which have been disinfected by UV irradiation. In addition, our results indicated that green fluorescent dyes are not suitable to be used with chlorine disinfected samples.


Jurnal BIOMA ◽  
2017 ◽  
Vol 11 (1) ◽  
pp. 73
Author(s):  
Rezki Rachmawati ◽  
Muzajjanah Muzajjanah ◽  
Yoswita Rustam

Refill Water Depot is currently more widely circulated and used as an alternative drinking water supply by the public. However the still unclear about the quality of the drinking water refill generated primarily of biological content. Parameters of biological contamination in drinking water caused by the Escherichia coli and coliform bacterium. This study aims to identify E. coli and coliforms in drinking water refill. Refill drinking water samples obtained from 16 drinking water refill from Jagakarsa subdsitrict. The method used is descriptive. Refill drinking water samples was taken and tested in the MPN (Most Probable Number) method and then to be tested in identification of E. coli. The results of testing the drinking water refill obtained 15 samples positive for coliform bacteria. Samples were positive for E. coli bacteria that sample B.1 and F.2.


2019 ◽  
Vol 14 (1) ◽  
pp. 1-8 ◽  
Author(s):  
Banin Maghfirotin Marta ◽  
Utami Tyas ◽  
Cahyanto Muhammad Nur ◽  
Widada Jaka ◽  
Rahayu Endang Sutriswati

Consumption of probiotics is known to influence the gut microbiota. The aim of this study was to assess the effect of probiotic powder containing Lactobacillus plantarum Dad-13 on bacterial composition in the gut by examining fecal samples of school-age children in Yogyakarta, Indonesia. This is a randomized, double-blind, placebo-controlled study. A total of 40 healthy subjects were recruited for this study and were divided into two groups: placebo group and probiotic group. The placebo group consumed skim milk and the probiotic group consumed probiotic powder containing L. plantarum Dad-13 (2 × 109 CFU/g) for 65 days. The results showed that placebo intake had no significant effect on gut microbiota; however, probiotic caused a significant increase in L. plantarum and Lactobacillus population, while decreasing the population of E. coli and non-E. coli coliform bacteria by 55% and 75%, respectively and Bifidobacteria count did not change significantly. The study concluded that consumption of probiotic powder L. plantarum Dad-13 could increase propionic acid thereby decreasing the gut pH which has an effect on the microbial population.


2004 ◽  
Vol 4 (2) ◽  
pp. 39-45 ◽  
Author(s):  
M.-L. Hänninen ◽  
R. Kärenlampi

The sources for drinking water in Finland are surface water, groundwater or artificially recharged groundwater. There are approximately 1400 groundwater plants in Finland that are microbiologically at a high risk level because in most cases they do not use any disinfection treatment. Campylobacter jejuni has caused waterborne epidemics in several countries. Since the middle of the 1980s, C. jejuni has been identified as the causative agent in several waterborne outbreaks in Finland. Between 1998 and 2001, C. jejuni or C. upsaliensis caused seven reported waterborne epidemics. In these epidemics approximately 4000 people acquired the illness. Most of the outbreaks occurred in July, August , September or October. In four of them source water and net water samples were analysed for total coliforms or fecal coliforms, E. coli and campylobacters. We showed that large volumes of water samples in studies of indicator organisms (up to 5000 ml) and campylobacters (4000–20,000 ml) increased the possibility to identify faecal contamination and to detect the causative agent from suspected sources.