Influence of Geometrical Parameters and Reynolds Number on Flat Plate Film Cooling Effectiveness

2021 ◽  
Author(s):  
Samaneh Rouina ◽  
Hamed Abdeh ◽  
Antonio Perdichizzi ◽  
Giovanna Barigozzi ◽  
Vittorio Odemondo ◽  
...  
Author(s):  
S. Rouina ◽  
H. Abdeh ◽  
A. Perdichizzi ◽  
G. Barigozzi ◽  
V. Odemondo ◽  
...  

Abstract In the present paper the influence of geometrical deviations, related to the manufacturing process or to a different hole positioning over the vane surface, and of coolant Reynolds number on flat plate film cooling through shaped holes are experimentally investigated. Hole geometrical parameters, such as the length of the cylindrical section, hole injection angle, lateral and forward expansion angles were varied and tested for blowing ratio M values between 1.0 and 2.0, also changing the coolant Reynolds number. The dual-luminophore Pressure Sensitive Paint (PSP) technique was used for measuring the adiabatic film cooling effectiveness distribution. Compared with the standard geometry, the V-shaped hole was shown to produce a better thermal protection, especially in the near hole region. Effectiveness is strongly affected by relatively small changes in the hole geometry, like the length of the cylindrical section and the forward expansion angle. A critical coolant Reynolds number was also identified, whose value changes depending on the hole geometry.


Author(s):  
Zhongran Chi ◽  
Chang Han ◽  
Xueying Li ◽  
Jing Ren ◽  
Hongde Jiang

A tripod cylindrical film hole with asymmetric side holes is studied numerically and experimentally on a flat plate for higher film cooling effectiveness. Firstly, the influences of geometrical parameters are studied and the optimum configurations of the asymmetric tripod hole are found in a DoE optimization study based on an improved numerical model for film cooling prediction, in which more than one hundred 3D CFD simulations are carried out. Then one optimum configuration of the asymmetric tripod hole is examined experimentally using pressure-sensitive paint (PSP) measurements, and compared against the experimental results of the simple cylindrical film hole and a well-designed shaped film hole. The flow and heat transfer characteristics of the asymmetric tripod holes were explored from the DoE results. The side holes can form a shear vortex system or an anti-kidney vortex system when proper spanwise distances of them are adopted, which laterally transports the coolant and form a favorable coolant coverage. According to the experimental results, the cooling performance of the optimized asymmetric tripod hole is significantly better than that of the simple cylindrical hole, especially at high blowing ratios. And the optimized asymmetric tripod hole can provide almost the same or even higher film cooling effectiveness on the flat plate compared with the shaped hole in the same flow conditions.


Author(s):  
Devaraj K

Abstract: The present computational study involves a flat plate subjected to combined effect of jet impingement and film cooling. A conjugate heat transfer model in conjunction with k-ω SST turbulence model is employed to study the turbulence effects. The effect of Reynolds number varying from 389 to 2140 on static temperature, Nusselt number and film cooling effectiveness has be discussed for the blowing ratios of 0.6, 0.8, 1.0. The variation in the size of vortices formed on the impinging surface with Reynolds number is studied. It has been observed that the local Nusselt number shows a rising trend with the increase in Reynolds number, while the static temperatures follow the downfall in its values. As a result, an enhancement in the effectiveness is observed, which is credited to the capabilities of combined impingement and film cooling. At Reynolds number of 972, the coolant jet is found to be attached to the surface, for this condition the heat transfer phenomena for blowing ratios of 0.6, 0.8, 1.0, 1.2, 1.6, 2.0, 2.4, 2.6 are studied to understand the flow distribution on the plate surface. Keywords: Jet impingement, film cooling, effectiveness, conjugate heat transfer


2016 ◽  
Vol 138 (6) ◽  
Author(s):  
Zhongran Chi ◽  
Jing Ren ◽  
Hongde Jiang ◽  
Shusheng Zang

A tripod cylindrical film hole with asymmetric side holes is studied numerically and experimentally on a flat plate for higher film cooling effectiveness. First, the influences of geometrical parameters are studied and the optimum configurations of the asymmetric tripod hole are found in a design of experiments (DoE) optimization study based on an improved numerical model for film cooling prediction, in which more than 100 3D computational fluid dynamics (CFD) simulations are carried out. Then, one optimum configuration of the asymmetric tripod hole is examined experimentally using pressure-sensitive paint (PSP) measurements and compared to the experimental results of the simple cylindrical film hole and a well-designed shaped film hole. The flow and heat transferring characteristics of the asymmetric tripod holes were explored from the DoE results. The side holes can form a shear vortex system or an antikidney vortex system when proper spanwise distances between them are adopted, which laterally transports the coolant and form a favorable coolant coverage. According to the experimental results on flat plate, the optimal configuration of the asymmetric tripod hole is significantly better than cylindrical hole, especially at high blowing ratios. Furthermore, it can provide equivalent or even higher film cooling effectiveness than a well-designed shaped hole.


Author(s):  
S. Baldauf ◽  
A. Schulz ◽  
S. Wittig

Local adiabatic film cooling effectiveness on a flat plate surface downstream a row of cylindrical holes was investigated. Geometrical parameters like blowing angle and hole pitch as well as the flow parameters blowing rate and density ratio were varied in a wide range emphasizing on engine relevant conditions. An IR-thermography technique was used to perform local measurements of the surface temperature field. A spatial resolution of up to 7 data points per hole diameter extending up to 80 hole diameters downstream of the ejection location was achieved. Since all technical surface materials have a finite thermoconductivity, no ideal adiabatic conditions could be established. Therefore, a procedure for correcting the measured surface temperature data based on a Finite Element analysis was developed. Heat loss over the backside of the testplate and remnant heat flux within the testplate in lateral and streamwise direction were taken into account. The local effectiveness patterns obtained are systematically analyzed to quantify the influence of the various parameters. As a result, a detailed description of the characteristics of local adiabatic film cooling effectiveness is given. Furthermore, the locally resolved experimental results can serve as a data base for the validation of CFD-codes predicting discrete hole film cooling.


2021 ◽  
Author(s):  
Siavash Khajehhasani

A numerical investigation of the film cooling performance on novel film hole schemes is presented using Reynolds-Averaged Navier-Stokes analysis. The investigation considers low and high blowing ratios for both flat plate film cooling and the leading edge of a turbine blade. A novel film hole geometry using a circular exit shaped hole is proposed, and the influence of an existing sister holes’ technique is investigated. The results indicate that high film cooling effectiveness is achieved at higher blowing ratios, results of which are even greater when in the presence of discrete sister holes where film cooling effectiveness results reach a plateau. Furthermore, a decrease in the strength of the counter-rotating vortex pairs is evident, which results in more attached coolant to the plate’s surface and a reduction in aerodynamic losses. Modifications are made to the spanwise and streamwise locations of the sister holes around the conventional cylindrical hole geometry. It is found that the spanwise variations have a significant influence on the film cooling effectiveness results, while only minor effects are observed for the streamwise variations. Positioning the sister holes in locations farther from the centerline increases the lateral spreading of the coolant air over the plate’s surface. This result is further verified through the flow structure analysis. Combinations of sister holes are joined with the primary injection hole to produce innovative variant sister shaped single-holes. The jet lift-off is significantly decreased for the downstream and up/downstream configurations of the proposed scheme for the flat plate film cooling. These schemes have shown notable film cooling improvements whereby more lateral distribution of coolant is obtained and less penetration of coolant into the mainstream flow is observed. The performance of the sister shaped single-holes are evaluated at the leading edge of a turbine blade. At the higher blowing ratios, a noticeable improvement in film cooling performance including the effectiveness and the lateral spread of the cooling air jet has been observed for the upstream and up/downstream schemes, in particular on the suction side. It is determined that the mixing of the coolant with the high mainstream flow at the leading edge of the blade is considerably decreased for the upstream and up/downstream configurations and more adhered coolant to the blade’s surface is achieved.


2021 ◽  
Author(s):  
Jie Wang ◽  
Chao Zhang ◽  
Xuebin Liu ◽  
Liming Song ◽  
Jun Li ◽  
...  

Abstract Aiming at investigating the effects of crossflow and vortex generator on film cooling characteristics of fan-shaped hole, the film cooling performance was measured experimentally by infrared camera. The blowing ratio is fixed at 0.5 and 1.5. The Reynolds number of the mainstream based on the hole diameter remains at 7000 and the inlet Reynolds number of crossflow is 40000. The experimental results show that the film cooling performance becomes better when the blowing ratio increases from 0.5 to 1.5 for each model, and the film cooling performance becomes worse under the influence of crossflow. When the blowing ratio is 1.5, the area-averaged film cooling effectiveness of the fan-shaped hole model with vortex generator decreases by 16.6% because of the influence of crossflow. The combined model always performs better compared with the model without vortex generator under all working conditions. When the blowing ratio becomes 1.5, under the influence of crossflow, the area-averaged film cooling effectiveness of the combined model could increase by 14.8%, compared with the model without vortex generator. To further improve the film cooling performance, the global optimization algorithm based on the Kriging method and the CFD technology are coupled to optimize the combined model under crossflow condition at the high blowing ratio, and the optimized design is verified by experiments. The experimental results show that the area-averaged film cooling effectiveness of the optimized design increases by 17.8% compared with the reference model.


2019 ◽  
Vol 141 (5) ◽  
Author(s):  
Jiaxu Yao ◽  
Jin Xu ◽  
Ke Zhang ◽  
Jiang Lei ◽  
Lesley M. Wright

The film cooling effectiveness distribution and its uniformity downstream of a row of film cooling holes on a flat plate are investigated by pressure sensitive paint (PSP) under different density ratios. Several hole geometries are studied, including streamwise cylindrical holes, compound-angled cylindrical holes, streamwise fan-shape holes, compound-angled fan-shape holes, and double-jet film-cooling (DJFC) holes. All of them have an inclination angle (θ) of 35 deg. The compound angle (β) is 45 deg. The fan-shape holes have a 10 deg expansion in the spanwise direction. For a fair comparison, the pitch is kept as 4d for the cylindrical and the fan-shape holes, and 8d for the DJFC holes. The uniformity of effectiveness distribution is described by a new parameter (Lateral-Uniformity, LU) defined in this paper. The effects of density ratios (DR = 1.0, 1.5 and 2.5) on the film-cooling effectiveness and its uniformity are focused. Differences among geometries and effects of blowing ratios (M = 0.5, 1.0, 1.5, and 2.0) are also considered. The results show that at higher density ratios, the lateral spread of the discrete-hole geometries (i.e., the cylindrical and the fan-shape holes) is enhanced, while the DJFC holes is more advantageous in film-cooling effectiveness. Mostly, a higher lateral-uniformity is obtained at DR = 2.5 due to better coolant coverage and enhanced lateral spread, but the effects of the density ratio on the lateral-uniformity are not monotonic in some cases. Utilizing the compound angle configuration leads to an increased lateral-uniformity due to a stronger spanwise motion of the jet. Generally, with a higher blowing ratio, the lateral-uniformity of the discrete-hole geometries decreases due to narrower traces, while that of the DJFC holes increases due to a stronger spanwise movement.


Author(s):  
Zachary T. Stratton ◽  
Tom I-P. Shih

Large eddy simulations (LES) were performed to investigate film cooling of a flat plate, where the cooling jets issued from a plenum through one row of circular holes of diameter D and length 4.7D that are inclined at 35° relative to the plate. The focus is on understanding the turbulent structure of the film-cooling jet and the film-cooling effectiveness. Parameters studied include blowing ratio (BR = 0.5 and 1.0) and density ratio (DR = 1.1 and 1.6). Also, two different boundary layers (BL) upstream of the film-cooling hole were investigated — one in which a laminar BL was tripped to become turbulent from near the leading edge of the flat plate, and another in which a mean turbulent BL is prescribed directly. The wall-resolved LES solutions generated were validated by comparing its time-averaged values with data from PIV and thermal measurements. Results obtained show that having an upstream BL that does not have turbulent fluctuations enhances the cooling effectiveness significantly at low velocity ratios (VR) when compared to an upstream BL that resolved the turbulent fluctuations. However, these differences diminish at higher VRs. Instantaneous flow reveals a bifurcation in the jet vorticity as it exits the hole at low VRs, one branch forming the shear-layer vortex, while the other forms the counter-rotating vortex pair. At higher VRs, the shear layer vorticity is found to reverse direction, changing the nature of the turbulence and the heat transfer. Results obtained also show the strength and structure of the turbulence in the film-cooling jet to be strongly correlated to VR.


Sign in / Sign up

Export Citation Format

Share Document