Effects of Inserting a Pressensor Film Into Articular Joints on the Actual Contact Mechanics

1998 ◽  
Vol 120 (5) ◽  
pp. 655-659 ◽  
Author(s):  
J. Z. Wu ◽  
W. Herzog ◽  
M. Epstein

Fuji film has been widely used in studies aimed at obtaining the contact mechanics of articular joints. Once sealed for practical use in biological joints, Fuji Pressensor film has a total effective thickness of 0.30 mm, which is comparable to the cartilage thickness in the joints of many small animals. The average effective elastic modulus of Fuji film is approximately 100 MPa in compression, which is larger by a factor of 100–300 compared to that of normal articular cartilage. Therefore, inserting a Pressensor film into an articular joint will change the contact mechanics of the joint. The measurement precision of the Pressensor film has been determined systematically; however, the changes in contact mechanics associated with inserting the film into joints have not been investigated. This study was aimed at quantifying the changes in the contact mechanics associated with inserting sealed Fuji Pressensor film into joints. Spherical and cylindrical articular joint contact mechanics with and without Pressensor film and for varying degrees of surface congruency were analyzed and compared by using finite element models. The Pressensor film was taken as linearly elastic and the cartilage was assumed to be biphasic, composed of a linear elastic solid phase and an inviscid fluid phase. The present analyses showed that measurements of the joint contact pressures with Fuji Pressensor film will change the maximum true contact pressures by 10–26 percent depending on the loading, geometry of the joints, and the mechanical properties of cartilage. Considering this effect plus the measurement precision of the film (approximately 10 percent), the measured joint contact pressures in a joint may contain errors as large as 14–28 percent.

2021 ◽  
Vol 115 ◽  
pp. 110163
Author(s):  
Mao Li ◽  
Mikko S. Venäläinen ◽  
Shekhar S. Chandra ◽  
Rushabh Patel ◽  
Jurgen Fripp ◽  
...  

2007 ◽  
Vol 129 (11) ◽  
pp. 1415-1421 ◽  
Author(s):  
Joseph Borowsky ◽  
Timothy Wei

An experimental investigation of a two-phase pipe flow was undertaken to study kinematic and dynamic parameters of the fluid and solid phases. To accomplish this, a two-color digital particle image velocimetry and accelerometry (DPIV∕DPIA) methodology was used to measure velocity and acceleration fields of the fluid phase and solid phase simultaneously. The simultaneous, two-color DPIV∕DPIA measurements provided information on the changing characteristics of two-phase flow kinematic and dynamic quantities. Analysis of kinematic terms indicated that turbulence was suppressed due to the presence of the solid phase. Dynamic considerations focused on the second and third central moments of temporal acceleration for both phases. For the condition studied, the distribution across the tube of the second central moment of acceleration indicated a higher value for the solid phase than the fluid phase; both phases had increased values near the wall. The third central moment statistic of acceleration showed a variation between the two phases with the fluid phase having an oscillatory-type profile across the tube and the solid phase having a fairly flat profile. The differences in second and third central moment profiles between the two phases are attributed to the inertia of each particle type and its response to turbulence structures. Analysis of acceleration statistics provides another approach to characterize flow fields and gives some insight into the flow structures, even for steady flows.


2014 ◽  
Vol 136 (4) ◽  
Author(s):  
Joshua E. Johnson ◽  
Phil Lee ◽  
Terence E. McIff ◽  
E. Bruce Toby ◽  
Kenneth J. Fischer

Joint injuries and the resulting posttraumatic osteoarthritis (OA) are a significant problem. There is still a need for tools to evaluate joint injuries, their effect on joint mechanics, and the relationship between altered mechanics and OA. Better understanding of injuries and their relationship to OA may aid in the development or refinement of treatment methods. This may be partially achieved by monitoring changes in joint mechanics that are a direct consequence of injury. Techniques such as image-based finite element modeling can provide in vivo joint mechanics data but can also be laborious and computationally expensive. Alternate modeling techniques that can provide similar results in a computationally efficient manner are an attractive prospect. It is likely possible to estimate risk of OA due to injury from surface contact mechanics data alone. The objective of this study was to compare joint contact mechanics from image-based surface contact modeling (SCM) and finite element modeling (FEM) in normal, injured (scapholunate ligament tear), and surgically repaired radiocarpal joints. Since FEM is accepted as the gold standard to evaluate joint contact stresses, our assumption was that results obtained using this method would accurately represent the true value. Magnetic resonance images (MRI) of the normal, injured, and postoperative wrists of three subjects were acquired when relaxed and during functional grasp. Surface and volumetric models of the radiolunate and radioscaphoid articulations were constructed from the relaxed images for SCM and FEM analyses, respectively. Kinematic boundary conditions were acquired from image registration between the relaxed and grasp images. For the SCM technique, a linear contact relationship was used to estimate contact outcomes based on interactions of the rigid articular surfaces in contact. For FEM, a pressure-overclosure relationship was used to estimate outcomes based on deformable body contact interactions. The SCM technique was able to evaluate variations in contact outcomes arising from scapholunate ligament injury and also the effects of surgical repair, with similar accuracy to the FEM gold standard. At least 80% of contact forces, peak contact pressures, mean contact pressures and contact areas from SCM were within 10 N, 0.5 MPa, 0.2 MPa, and 15 mm2, respectively, of the results from FEM, regardless of the state of the wrist. Depending on the application, the MRI-based SCM technique has the potential to provide clinically relevant subject-specific results in a computationally efficient manner compared to FEM.


1977 ◽  
Vol 99 (2) ◽  
pp. 163-172 ◽  
Author(s):  
Joseph M. Mansour ◽  
Van C. Mow

Fluid flow and mass transport mechanisms associated with articular cartilage function are important biomechanical processes of normal and pathological synovial joints. A three-layer permeable, two-phase medium of an incompressible fluid and a linear elastic solid are used to model the flow and deformational behavior of articular cartilage. The frictional resistance of the relative motion of the fluid phase with respect to the solid phase is given by a linear diffusive dissipation term. The subchondral bony substrate is represented by an elastic solid. The three-layer model of articular cartilage is chosen because of the known histological, ultrastructural, and biomechanical variations of the tissue properties. The calculated flow field shows that for material properties of normal healthy articular cartilage the tissue creates a naturally lubricated surface. The movement of the interstitial fluid at the surface is circulatory in manner, being exuded in front and near the leading half of the moving surface load and imbibed behind and near the trailing half of the moving load. The flow fields of healthy tissues are capable of sustaining a film of fluid at the articular surface whereas pathological tissues cannot.


Author(s):  
Andrew E. Anderson ◽  
Steve A. Maas ◽  
Benjamin J. Ellis ◽  
Jeffrey A. Weiss

Simplified analytical approaches to estimate hip joint contact pressures using perfectly spherical geometry have been described in the literature (rigid body spring models); however, estimations based on these simulations have not corresponded well with experimental in vitro data. Recent evidence from our laboratory suggests that finite element (FE) models of the hip joint that incorporate detailed geometry for cartilage and bone can predict cartilage pressures in good agreement with experimental data [1]. However, it is unknown whether this degree of model complexity is necessary. The objective of this study was to compare cartilage contact pressure predictions from FE models with varying degrees of simplicity to elucidate which aspects of hip morphology are required to obtain accurate predictions of cartilage contact pressure. Models based on 1) subject-specific (SS) geometry, 2) spheres, and 3) rotational conchoids were analyzed.


2019 ◽  
Vol 2 (2) ◽  
pp. 61-77
Author(s):  
Puskar R. Pokhrel ◽  
Bhadra Man Tuladhar

In this paper, we present simple and exact eigenvalues for both the solid- and fluid-phases of the real two-phase general model developed by Pudasaini (2012); we call these phase-eigenvalues, the solid- phase-eigenvalues and the fluid-phase-eigenvalues. Results are compared by applying the derived phase- eigenvalues that incorporate the phase-interactions in the two-phase debris movements against the simple and classical solid and fluid eigenvalues without any phase interaction. We have constructed several different set of eigenvalues including the coupled phase eigenvalues by using rational factorization method. At first, we consider for general debris height; factorizing the solid and fluid lateral pressure contributions by considering the negligible pressure gradient; negligible solid lateral pressure; negligible fluid lateral pressure; negligible solid and fluid lateral pressure. Secondly, for a thin debris ow height, we also construct the fourth set of eigenvalues in three different cases. These phase-eigenvalues incorporate strong interaction between the solid and fluid dynamics. The simulation results are produced by taking all these different sets of coupled phase-eigenvalues and are compared with the classical uncoupled set of solid and fluid eigenvalues. The results indicate the importance of phase-eigenvalues and supports for a complete description of the phase- eigenvalues for the enhanced description of real two-phase debris flows and landslide motions.


2006 ◽  
Vol 11 (6) ◽  
pp. 575-595 ◽  
Author(s):  
L. Fusi ◽  
A. Farina ◽  
D. Ambrosi

The mechanical behavior of a mixture composed by an elastic solid and a fluid that exchange mass is investigated. Both the liquid flow and the solid deformation depend on how the solid phase has increased (diminished) its mass, i.e. on the mass conversion between constituents. The model is developed introducing a decomposition of the solid phase deformation gradient. In particular, exploiting the criterion of maximization of the rate of entropy production, we determine an explicit evolution equation for the so-called growth tensor which involves directly the solid stress tensor. An example of a possible choice of the constitutive functions is also presented.


2009 ◽  
Vol 30 (8) ◽  
pp. 767-772 ◽  
Author(s):  
Dong Gil Lee ◽  
Brian L. Davis

Background: One of the more serious diabetic complications is Charcot neuroarthropathy (CN), a disease that results in arch collapse and permanent foot deformity. However, very little is known about the etiology of CN. From a mechanical standpoint, it is likely that there is a “vicious circle” in terms of (i) arch collapse causing increased midfoot joint pressures, and (ii) increased joint contact pressures exacerbating the collapse of midfoot bones. This study focused on assessment of peak joint pressure difference between diabetic and non-diabetic cadaver feet during simulated walking. We hypothesized that joint pressures are higher for diabetics than normal population. Materials and Methods: Sixteen cadaver foot specimens (eight control and eight diabetic specimens) were used in this study. Human gait at 25% of typical walking speed (averaged stance duration of 3.2s) was simulated by a custom-designed Universal Musculoskeletal Simulator. Four medial midfoot joint pressures (the first metatarsocuneiform, the medial naviculocuneiform, the middle naviculocuneiform, and the first intercuneiform) were measured dynamically during full stance. Results: The pressures in each of the four measured midfoot joints were significantly greater in the diabetic feet ( p = 0.015, p = 0.025, p < 0.001, and p = 0.545, respectively). Conclusion: Across all four tested joints, the diabetic cadaver specimens had, on average, 46% higher peak pressures than the control cadaver feet during the simulated stance phase. Clinical Relevance: This finding suggests that diabetic patients could be predisposed to arch collapse even before there are visible signs of bone or joint abnormalities.


2018 ◽  
Vol 4 (1) ◽  
pp. 203-205
Author(s):  
Mehdi Saeidi ◽  
Maziar Ramezani ◽  
Piaras Kelly ◽  
Mohd Sabri Hussin ◽  
Thomas Neitzert

AbstractThis research aimed to study the efficacy of a novel implant for osteoarthritic knees. This implant is designed to eliminate excessive loads through the knee and to provide suitable conditions for possible tibiofemoral cartilage regeneration. The implant was designed for the medial side of the knee joint. Finite Element Analysis (FEA) was performed for an extended knee position of the knee joint. Contact pressure distributions on the medial and lateral compartments were investigated as well as stress distributions throughout the implant’s plates. Results with and without the implant were compared, and it was seen that the contact pressures on the surface of the distal femur were reduced by more than 90% after the introduction of the implant.


1992 ◽  
Vol 82 (5) ◽  
pp. 2263-2273
Author(s):  
M. D. Sharma

Abstract Philippacopoulos (1988) discusses axisymmetric wave propagation in a fluid-saturated porous solid half-space. The disturbance is considered to be produced by the concentrated load P0exp(iωt) acting vertically at the surface. Boundary conditions chosen imply that a vertical force acting on the surface of fluid-saturated porous solid exerts no pressure on the interstitial liquid. These boundary conditions do not seem appropriate. In the present study, the boundary conditions have been changed in order to satisfy the concept of porosity. These are also in accordance with those discussed by Deresiewicz and Skalak (1963) for the special case of interface between liquid and liquid-saturated porous media. Analytic expressions have been derived for the displacements at the surface. The limiting case of a dry elastic solid is also deduced. Effects of intergranular energy losses due to solid phase and of dissipation due to flow of pore fluid are exhibited on the displacements at the surface. Contrary to Philippacopoulos (1988), the displacements in saturated poroelastic solids are found to be larger than those in a dry elastic solid with same Lamb's moduli.


Sign in / Sign up

Export Citation Format

Share Document