Cooling of a Heated Surface by Mist Flow

1994 ◽  
Vol 116 (1) ◽  
pp. 167-172 ◽  
Author(s):  
S. L. Lee ◽  
Z. H. Yang ◽  
Y. Hsyua

Cooling requirements in modern industrial applications, such as the removal of heat from electronic equipments, often demand the simultaneous attainment of a high heat flux and a low and relatively uniform and steady temperature of the heated surface to be cooled. The conventional single-phase convection cooling obviously cannot be expected to function adequately, since the heat flux there is directly proportional to the temperature difference between the heated surface and the surrounding medium. To maintain a high heat flux, the temperature of the heated surface usually must be kept at a high level. An attractive alternative is cooling by a spray, which takes advantage of the significant latent heat of evaporation of the liquid. However, in conventional industrial spray coolings, such as in the case of the cooling tower of a power plant, the temperature of the heated surface usually remains relatively high and is nonuniform and unsteady containing numerous flashy hot spots. In order to optimize the performance of the spray cooling of a heated surface by a mist flow, a clear understanding is required of (1) the dynamic interaction between the droplets and the carrier fluid and (2) the thermal reception of the droplets at the heated surface. It is the dynamic interaction between the phases that is causing the droplets to deposit onto the heated surface. The thermal reception at the heated wall develops mass and heat transfer leading to the mode of cooling of the heated surface. In the present study, an experimental investigation was made of the combination of the dynamic depositional behavior of droplets in a water droplet-air mist flow with the use of a specially designed particle-sizing two-dimensional laser-Doppler anemometer. Also, the heat transfer characteristics at the heated surface were investigated in relation to droplet deposition on the heated surface for wide ranges of droplet size, droplet concentration, mist flow velocity, and heat flux. It was discovered that over a certain suitable range of combination of these parameters, a superbly effective cooling scheme could be established by the evaporation on the outside surface of an ultrathin liquid film. Such a film was formed on the heated surface by the continuous deposition of fine droplets from the mist flow. Under these conditions, the heat flux is primarily related to the evaporation of the ultrathin liquid film on the heated surface and thus depends less on the temperature difference between the heated surf ace and the ambient mist flow. The heated surface is quenched to a low, relatively uniform and steady temperature at a very high level of heat flux. Heat transfer enhancement as high as seven times has been found so far. This effective heat transfer scheme is here termed mist cooling.

2016 ◽  
Vol 138 (2) ◽  
Author(s):  
Taolue Zhang ◽  
Jorge Alvarado ◽  
J. P. Muthusamy ◽  
Anoop Kanjirakat ◽  
Reza Sadr

The objective of this study is to investigate the effects of droplet-induced crown propagation regimes (spreading and splashing) on liquid film hydrodynamics and heat transfer. In this work, the effects of high frequency droplet train impingement on spreading-splashing transition, liquid film hydrodynamics and surface heat transfer were investigated experimentally. HFE-7100 droplet train was generated using a piezo-electric droplet generator at a fixed flow rate of 165 mL/h. Optical and IR images were captured at stable droplet impingement conditions to visualize the thermal physical process. The droplet-induced crown propagation transition phenomena from spreading to splashing were observed by increasing the droplet Weber number. The liquid film hydrodynamics induced by droplet train impingement becomes more complex when the surface was heated. Bubbles and micro-scale fingering phenomena were observed outside the impact crater under low heat flux conditions. Dry-out was observed outside the impact craters under high heat flux conditions. IR images of the heater surface show that heat transfer was most effective within the droplet impact crater zone due to high fluid inertia including high radial momentum caused by high-frequency droplet impingement. Time-averaged heat transfer measurements indicate that the heat flux-surface temperature curves are linear at low surface temperature and before the onset of dry-out. However, a sharp increase in surface temperature can be observed when dry-out appears on the heater surface. Results also show that strong splashing (We = 850) is unfavorable for heat transfer at high heat flux conditions due to instabilities of the liquid film, which lead to the onset of dry-out. In summary, the results show that droplet Weber number is a significant factor in the spreading-splashing transition, liquid film hydrodynamics and heat transfer.


2012 ◽  
Vol 134 (12) ◽  
Author(s):  
Sergio Escobar-Vargas ◽  
Jorge E. Gonzalez ◽  
Drazen Fabris ◽  
Ratnesh Sharma ◽  
Cullen Bash

This work is aimed at cooling small surfaces (1.3 mm × 2 mm and 3 mm × 5 mm) using spray from thermal ink jet (TIJ) atomizers. Particular interests in this work include obtaining heat fluxes near the critical heat flux (CHF), understanding the correlation between the heat dissipation efficiency (η) and the liquid film thickness (δ) through experimental data, and understanding the primary mode of heat transfer on spray cooling at different liquid film thickness. Current experimental results indicate that high heat fluxes (∼4 × 107 W/m2) are obtained for controlled conditions of cooling mass flow rate, higher efficiencies are achieved at smaller liquid film thickness (δ ≈ 5 μm → η ≈ 0.9), and the heat transfer by conduction through the film becomes dominant as δ decreases.


2020 ◽  
Vol 142 (7) ◽  
Author(s):  
Junye Li ◽  
Yuhao Lin ◽  
Wei Li ◽  
Kan Zhou

Abstract An experimental study of saturated flow boiling in a high-aspect-ratio one-side-heating rectangular microchannel was conducted with de-ionized water as the working fluid. ZnO microrods with the average diameter of about 1 μm and length of about 7 μm were synthesized on the Ti wafer surface, which was used to fabricate the heated bottom surface of the microchannel. The ZnO microrod surface appeared to be hydrophobic and the capillary wetting effect on the surface was found after being wet. The heat transfer and pressure drop characteristics of saturated flow boiling in the microchannel were studied and the flow patterns were photographed with a high-speed camera. Almost all the flow patterns observed in this experiment featured the main annular flow and abrupt flush of bubbly flow. Because of the capillary wetting effect on the ZnO microrod surface, the local dryout and rewetting phenomenon did not appear in this study. However, due to the numerous nucleation sites on ZnO microrod surface, the abrupt bubble flow caused much more disruption to the liquid film of annular flow when compared to the regular silicon surface. The abrupt bubble flow flushed through the annular liquid film and caused the fluctuation and nonuniformity of the liquid film and heat transfer deterioration, which was severer in the high heat flux conditions. Otherwise, the capillary effect on the ZnO microrod surface was able to restrict the nonuniformity of the liquid film under high heat flux and low mass flux conditions; thus, the deterioration of heat transfer performances diminished.


1998 ◽  
Vol 35 (9) ◽  
pp. 671-678 ◽  
Author(s):  
Md. Shafiqul ISLAM ◽  
Ryutaro HINO ◽  
Katsuhiro HAGA ◽  
Masanori MONDE ◽  
Yukio SUDO

Author(s):  
Shinichi Miura ◽  
Yukihiro Inada ◽  
Yasuhisa Shinmoto ◽  
Haruhiko Ohta

Advance of an electronic technology has caused the increase of heat generation density for semiconductors densely integrated. Thermal management becomes more important, and a cooling system for high heat flux is required. It is extremely effective to such a demand using flow boiling heat transfer because of its high heat removal ability. To develop the cooling system for a large area at high heat flux, the cold plate structure of narrow channels with auxiliary unheated channel for additional liquid supply was devised and confirmed its validity by experiments. A large surface of 150mm in heated length and 30mm in width with grooves of an apex angle of 90 deg, 0.5mm depth and 1mm in pitch was employed. A structure of narrow rectangular heated channel between parallel plates with an unheated auxiliary channel was employed and the heat transfer characteristics were examined by using water for different combinations of gap sizes and volumetric flow rates. Five different liquid distribution modes were tested and their data were compared. The values of CHF larger than 1.9×106W/m2 for gap size of 2mm under mass velocity based on total volumetric flow rate and on the cross section area of main heated channel 720kg/m2s or 1.7×106W/m2 for gap size of 5mm under 290kg/m2s were obtained under total volumetric flow rate 4.5×10−5m3/s regardless of the liquid distribution modes. Under several conditions, the extensions of dry-patches were observed at the upstream location of the main heated channel resulting burnout not at the downstream but at the upstream. High values of CHF larger than 2×106W/m2 were obtained only for gap size of 2mm. The result indicates that higher mass velocity in the main heated channel is more effective for the increase in CHF. It was clarified that there is optimum flow rate distribution to obtain the highest values of CHF. For gap size of 2mm, high heat transfer coefficient as much as 7.4×104W/m2K were obtained at heat flux 1.5×106W/m2 under mass velocity 720kg/m2s based on total volumetric flow rate and on the cross section area of main heated channel. Also to obtain high heat transfer coefficient, it is more useful to supply the cooling liquid from the auxiliary unheated channel for additional liquid supply in the transverse direction perpendicular to the flow in the main heated channel.