measurement of thickness
Recently Published Documents


TOTAL DOCUMENTS

289
(FIVE YEARS 19)

H-INDEX

16
(FIVE YEARS 2)

Author(s):  
Carlos Romero ◽  
Vanesa Abuín Porras ◽  
Emmanuel Navarro Flores ◽  
Patricia López ◽  
Victoria Mazoteras Pardo ◽  
...  

IntroductionUltrasound imaging (USI) is useful to evaluate structures of the foot to guide treatment, but the reliability of USI technique needs to be clarified. The goal of the study was to evaluate the intra- and inter-examiner reliability of USI image capture, and measurement of the cross-sectional area (CSA) and thickness of the flexor hallucis longus (FHL) for experienced and novice examinersMaterial and methodsFHL images were captured for 20 healthy adults. Reliability of image capture was evaluated between images repeated at 10-min interval for an experienced and a novice examiner. Reliability of image-based measurements was evaluated for one experienced and one novice rater, using all images. The intra-class correlation coefficient (ICC) and the standard error of measurement (SEM) were calculatedResultsIntra-examiner reliability of image capture for the FHL muscle examined by USI was excellent for both thickness (ICC3,1, 0.944–0.976; SEM, 6.8%–10.0%) and CSA (ICC3,1, 0.954–0.979; SEM, 10.8%–16.5%), with no effect of examiner experience. Reliability was also excellent for measurement of thickness (ICC3,1, 0.954–0.972; SEM, 1.2%–9.6%) and CSA (ICC3,1, 0.961–0.986; SEM, 9.2%–14.1%), with no effects of experience.ConclusionsReliability of image capture and image-based measurements developed by USI of CSA and thickness for the FHL muscle in healthy individuals was excellent, independent of the examiner experience.


2021 ◽  
Vol 92 (2) ◽  
pp. 023307
Author(s):  
M. Bertucci ◽  
A. Bosotti ◽  
R. Campari ◽  
A. D’Ambros ◽  
A. Gresele ◽  
...  

2020 ◽  
Vol 11 (2) ◽  
pp. 124-129
Author(s):  
Lutfun Nahar ◽  
Ahmad Seraji ◽  
Md Shofiur Rahman ◽  
Md Redwan Ahsanullah

Study on the Thicknesses and the Girths of Tendoachilles of Human Cadavers. Background: Tendoachilles is the chief planter flexor of the ankle joint. It provides elastic energy storage in walking and running. The present study was planned to collect data to find out possible variations of thickness and girth between right and left leg of both male and female. Materials and methods: A cross sectional analytical type of study was conducted in the department of Anatomy, Dhaka Medical College, Dhaka, from July 2013 to June 2014. The data was collected from both right and left tendoachilles of 60 human cadaver taken from Anatomy Department of different Government and Nongovernment Medical Colleges in Dhaka city. After dissection thickness and girth of tendoachilles was measured and recorded. Results: Among 60 human cadaver, 30 are male and 30 are female. The mean thickness of tendoachilles was greater in right leg than in left leg at its junction with gastrocnemius in male, (P<0.001) at the level of 4 cm above its junction with calcaneus and at the level of its junction with calcaneus in both male and female. No significant difference was observed in the measurement of thickness of right and left tendoachilles at the level of its junction with gastrocnemius in female. Mean girth of tendoachilles was greater in right leg than in left leg at its junction with gastrocnemius, at the level of 4 cm above its junction with calcaneus and at the level of its junction with calcaneus in both male and female. Conclusions: The present study revealed that thickness and girth of tendoachilles was greater in right leg than in left leg which were statistically significant. The difference in thickness and girth can be useful during repair of rupture tendon by orthopaedic and plastic surgeon. J Shaheed Suhrawardy Med Coll, December 2019, Vol.11(2); 124-129


Sign in / Sign up

Export Citation Format

Share Document