Letterbox Trailing Edge Heat Transfer: Effects of Blowing Rate, Reynolds Number, and External Turbulence on Heat Transfer and Film Cooling Effectiveness

2009 ◽  
Vol 132 (1) ◽  
Author(s):  
N. J. Fiala ◽  
I. Jaswal ◽  
F. E. Ames

Heat transfer and film cooling distributions have been acquired for a vane trailing edge with letterbox partitions. Additionally, pressure drop data have been experimentally determined across a pin fin array and a trailing edge slot with letterbox partitions. The pressure drop across the array and letterbox trailing edge arrangement was measurably higher than for the gill slot geometry. Experimental data for the partitions and the inner suction surface region downstream from the slot have been acquired over a four-to-one range in vane exit condition Reynolds number (500,000, 1,000,000, and 2,000,000), with low (0.7%), grid (8.5%), and aerocombustor (13.5%) turbulence conditions. At these conditions, both heat transfer and adiabatic film cooling distributions have been documented over a range of blowing ratios (0.47≤M≤1.9). Heat transfer distributions on the inner suction surface downstream from the slot ejection were found to be dependent on both ejection flow rate and external conditions. Heat transfer on the partition side surfaces correlated with both exit Reynolds number and blowing ratio. Heat transfer on partition top surfaces largely correlated with exit Reynolds number but blowing ratio had a small effect at higher values. Generally, adiabatic film cooling levels on the inner suction surface are high but decrease near the trailing edge and provide some protection for the trailing edge. Adiabatic effectiveness levels on the partitions correlate with blowing ratio. On the partition sides adiabatic effectiveness is highest at low blowing ratios and decreases with increasing flow rate. On the partition tops adiabatic effectiveness increases with increasing blowing ratio but never exceeds the level on the sides. The present paper, together with a companion paper that documents letterbox trailing edge aerodynamics, is intended to provide engineers with the heat transfer and aerodynamic loss information needed to develop and compare competing trailing edge designs.

Author(s):  
N. J. Fiala ◽  
I. Jaswal ◽  
F. E. Ames

Heat transfer and film cooling distributions have been acquired for a vane trailing edge with letterbox partitions. Additionally, pressure drop data have been experimentally determined across a pin fin array and a trailing edge slot with letterbox partitions. The pressure drop across the array and letterbox trailing edge arrangement was measurably higher than for the gill slot geometry. Experimental data for the partitions and the inner suction surface region downstream from the slot have been acquired over a four to one range in vane exit condition Reynolds number (500,000, 1,000,000 and 2,000,000), with low (0.7%), grid (8.5%), and aero-combustor (13.5%) turbulence conditions. At these conditions, both heat transfer and adiabatic film cooling distributions have been documented over a range of blowing ratios (0.47 ≤ M ≤ 1.9). Heat transfer distributions on the inner suction surface downstream from the slot ejection were found to be dependent on both ejection flow rate and external conditions. Heat transfer on the partition side surfaces correlated on both exit Reynolds number and blowing ratio. Heat transfer on partition top surfaces largely correlated on exit Reynolds number but blowing ratio had a small effect at higher values. Generally, adiabatic film cooling levels on the inner suction surface are high but decrease near the trailing edge and provide some protection for the trailing edge. Adiabatic effectiveness levels on the partitions correlate with blowing ratio. On the partition sides adiabatic effectiveness is highest at low blowing ratios and decreases with increasing flow rate. On the partition tops adiabatic effectiveness increases with increasing blowing ratio but never exceeds the level on the sides. The present paper, together with a companion paper which documents letterbox trailing edge aerodynamics, is intended to provide engineers with the heat transfer and aerodynamic loss information needed to develop and compare competing trailing edge designs.


Author(s):  
F. E. Ames ◽  
N. J. Fiala ◽  
J. D. Johnson

Heat transfer and film cooling distributions have been acquired downstream from the exit of a nozzle guide vane gill slot (or cutback). Additionally, heat transfer and pressure drop data have been experimentally determined for a pin fin array within the gill slot geometry. Generally, average row pin fin heat transfer levels for the converging channel correlate quite well with archival literature. However, no generalized flow friction factor correlation was found to predict the pressure drop within the array. Experimental data for the region downstream from the gill slot have been acquired over a four to one range in vane exit condition Reynolds number, with low, grid, and aero-combustor turbulence conditions. At these conditions, both heat transfer and adiabatic film cooling distributions have been documented over a range of blowing ratios. Heat transfer distributions downstream from the gill slot ejection were found to be dependent on both ejection flow rate and external conditions. Generally, adiabatic film cooling levels are high but dissipate toward the trailing edge and provide some protection on the trailing edge. Heat transfer levels on the trailing edge are affected largely by the chord exit Reynolds number and the suction surface boundary layer condition. The present paper, together with a companion paper which documents gill slot aerodynamics, is intended to provide designers with the heat transfer and aerodynamic loss information needed to compare competing trailing edge designs.


2012 ◽  
Vol 134 (5) ◽  
Author(s):  
Shakeel Nasir ◽  
Trey Bolchoz ◽  
Wing-Fai Ng ◽  
Luzeng J. Zhang ◽  
Hee Koo Moon ◽  
...  

This paper experimentally investigates the effect of blowing ratio and exit Reynolds number/Mach number on the film cooling performance of a showerhead film cooled first stage turbine vane. The vane midspan was instrumented with single-sided platinum thin film gauges to experimentally characterize the Nusselt number and film cooling effectiveness distributions over the surface. The vane was arranged in a two-dimensional, linear cascade in a heated, transonic, blow-down wind tunnel. Three different exit Mach numbers of Mex = 0.57, 0.76 and 1.0—corresponding to exit Reynolds numbers based on vane chord of 9.7 × 105, 1.1 × 106 and 1.5 × 106, respectively—were tested with an inlet free stream turbulence intensity (Tu) of 16% and an integral length scale normalized by vane pitch (Λx/P) of 0.23. A showerhead cooling scheme with five rows of cooling holes was tested at blowing ratios of BR = 0, 1.5, 2.0, and 2.5 and a density ratio of DR = 1.3. Nusselt number and adiabatic film cooling effectiveness distributions were presented on the vane surface over a range of s/C = −0.58 on the pressure side to s/C = 0.72 on the suction side of the vane. The primary effects of coolant injection were to augment the Nusselt number and reduce the adiabatic wall temperature downstream of the injection on the vane surface as compared to no film injection case (BR = 0) at all exit Mach number conditions. In general, an increase in blowing ratio (BR = 1.5 to 2.5) showed noticeable Nusselt number augmentation on pressure surface as compared to suction surface at exit Mach 0.57 and 0.75; however, the Nusselt number augmentation for these blowing ratios was found to be negligible on the vane surface for exit Mach 1.0 case. At exit Mach 1.0, an increase in blowing ratio (BR = 1.5 to 2.5) was observed to have an adverse effect on the adiabatic effectiveness on the pressure surface but had negligible effect on suction surface. The effectiveness trend on the suction surface was also found to be influenced by a favorable pressure gradient due to Mach number and boundary layer transition in the region s/C = 0.28 to s/C = 0.45 at all blowing ratio and exit Mach number conditions. An increase in Reynolds number from exit Mach 0.76 to 1.0 increased heat transfer levels on the vane surface at all blowing ratio conditions. A large increase in Reynolds number adversely affected adiabatic effectiveness on the pressure surface at all blowing ratio conditions. On the suction surface, a large increase in Reynolds number also affected adiabatic effectiveness in the favorable pressure gradient and boundary layer transition region.


Author(s):  
S. Nasir ◽  
T. Bolchoz ◽  
W. F. Ng ◽  
L. J. Zhang ◽  
H. K. Moon ◽  
...  

This paper experimentally investigates the effect of blowing ratio and exit Reynolds number/Mach number on the film cooling performance of a showerhead film cooled first stage turbine vane. The vane midspan was instrumented with single-sided platinum thin film gauges to experimentally characterize the Nusselt number and film cooling effectiveness distributions over the surface. The vane was arranged in a two-dimensional, linear cascade in a heated, transonic, blow-down wind tunnel. Three different exit Mach numbers of Mex = 0.57, 0.76 and 1.0—corresponding to exit Reynolds numbers based on vane chord of 9.7 × 105, 1.1 × 106 and 1.5 × 106, respectively—were tested with an inlet free stream turbulence intensity (Tu) of 16% and an integral length scale normalized by vane pitch (Λx/P) of 0.23. A showerhead cooling scheme with five rows of cooling holes was tested at blowing ratios of BR = 0, 1.5, 2.0, and 2.5 and a density ratio of DR = 1.3. Nusselt number and adiabatic film cooling effectiveness distributions were presented on the vane surface over a range of s/C = −0.58 on the pressure side to s/C = 0.72 on the suction side of the vane. The primary effects of coolant injection were to augment the Nusselt number and reduce the adiabatic wall temperature downstream of the injection on the vane surface as compared to no film injection case (BR = 0) at all exit Mach number conditions. In general, an increase in blowing ratio (BR = 1.5 to 2.5) showed noticeable Nusselt number augmentation on pressure surface as compared to suction surface at exit Mach 0.57 and 0.75; however, the Nusselt number augmentation for these blowing ratios was found to be negligible on the vane surface for exit Mach 1.0 case. At exit Mach 1.0, an increase in blowing ratio (BR = 1.5 to 2.5) was observed to have an adverse effect on the adiabatic effectiveness on the pressure surface but had negligible effect on suction surface. The effectiveness trend on the suction surface was also found to be influenced by a favorable pressure gradient due to Mach number and boundary layer transition in the region s/C = 0.28 to s/C = 0.45 at all blowing ratio and exit Mach number conditions. An increase in Reynolds number from exit Mach 0.76 to 1.0 increased heat transfer levels on the vane surface at all blowing ratio conditions. A large increase in Reynolds number adversely affected adiabatic effectiveness on the pressure surface at all blowing ratio conditions. On the suction surface, a large increase in Reynolds number also affected adiabatic effectiveness in the favorable pressure gradient and boundary layer transition region.


Author(s):  
L. W. Soma ◽  
F. E. Ames ◽  
S. Acharya

The trailing edge of a vane is one of the most difficult areas to cool due to a narrowing flow path, high external heat transfer rates, and deteriorating external film cooling protection. Converging pedestal arrays are often used as a means to provide internal cooling in this region. The thermally induced stresses in the trailing edge region of these converging arrays have been known to cause failure in the pedestals of conventional solidity arrays. The present paper documents the heat transfer and pressure drop through two high solidity converging rounded diamond pedestal arrays. These arrays have a 45 percent pedestal solidity. One array which was tested has nine rows of pedestals with an exit area in the last row consistent with the convergence. The other array has eight rows with an expanded exit in the last row to enable a higher cooling air flow rate. The expanded exit of the eight row array allows a 30% increase in the coolant flow rate compared with the nine row array for the same pressure drop. Heat transfer levels correlate well based on local Reynolds numbers but fall slightly below non converging arrays. The pressure drop across the array naturally increases toward the trailing edge with the convergence of the flow passage. A portion of the cooling air pressure drop can be attributed to acceleration while a portion can be attributed to flow path losses. Detailed array static pressure measurements provide a means to develop a correlation for the prediction of pressure drop across the cooling channel. Measurements have been acquired over Reynolds numbers based on exit flow conditions and the characteristic pedestal length scale ranging from 5000 to over 70,000.


2010 ◽  
Vol 132 (4) ◽  
Author(s):  
N. J. Fiala ◽  
J. D. Johnson ◽  
F. E. Ames

A letterbox trailing edge configuration is formed by adding flow partitions to a gill slot or pressure side cutback. Letterbox partitions are a common trailing edge configuration for vanes and blades, and the aerodynamics of these configurations are consequently of interest. Exit surveys detailing total pressure loss, turning angle, and secondary velocities have been acquired for a vane with letterbox partitions in a large-scale low speed cascade facility. These measurements are compared with exit surveys of both the base (solid) and gill slot vane configurations. Exit surveys have been taken over a four to one range in chord Reynolds numbers (500,000, 1,000,000, and 2,000,000) based on exit conditions and for low (0.7%), grid (8.5%), and aerocombustor (13.5%) turbulence conditions with varying blowing rate (50%, 100%, 150%, and 200% design flow). Exit loss, angle, and secondary velocity measurements were acquired in the facility using a five-hole cone probe at a measuring station representing an axial chord spacing of 0.25 from the vane trailing edge plane. Differences between losses with the base vane, gill slot vane, and letterbox vane for a given turbulence condition and Reynolds number are compared providing evidence of coolant ejection losses, and losses due to the separation off the exit slot lip and partitions. Additionally, differences in the level of losses, distribution of losses, and secondary flow vectors are presented for the different turbulence conditions at the different Reynolds numbers. The letterbox configuration has been found to have slightly reduced losses at a given flow rate compared with the gill slot. However, the letterbox requires an increased pressure drop for the same ejection flow. The present paper together with a related paper (2008, “Letterbox Trailing Edge Heat Transfer—Effects of Blowing Rate, Reynolds Number, and External Turbulence on Heat Transfer and Film Cooling Effectiveness,” ASME, Paper No. GT2008-50474), which documents letterbox heat transfer, is intended to provide designers with aerodynamic loss and heat transfer information needed for design evaluation and comparison with competing trailing edge designs.


Author(s):  
Renzo La Rosa ◽  
Jaideep Pandit ◽  
Wing Ng ◽  
Brett Barker

Abstract Heat transfer experiments were done on a flat plate to study the effect of internal counter-flow backside cooling on adiabatic film cooling effectiveness and heat transfer coefficient. In addition, the effects of density ratio (DR), blowing ratio (BR), diagonal length over diameter (L/D) ratio, and Reynolds number were studied using this new configuration. The results are compared to a conventional plenum fed case. Data were collected up to X/D = 23 where X = 0 at the holes, an S/D = 1.65 and L/D = 1 and 2. Testing was done at low L/D ratios since short holes are normally found in double wall cooling applications in turbine components. A DR of 2 was used in order to simulate engine-like conditions and this was compared to a DR of 0.92 since relevant research is done at similar low DR. The BR range of 0.5 to 1.5 was chosen to simulate turbine conditions as well. In addition, previous research shows that peak effectiveness is found within this range. Infrared (IR) thermography was used to capture temperature contours on the surface of interest and the images were calibrated using a thermocouple and data analyzed through MATLAB software. A heated secondary fluid was used as ‘coolant’ in the present study. A steady state heat transfer model was used to perform the data reduction procedure. Results show that backside cooling configuration has a higher adiabatic film cooling effectiveness when compared to plenum fed configurations at the same conditions. In addition, the trend for effectiveness with varying BR is reversed when compared with traditional plenum fed cases. Yarn flow visualization tests show that flow exiting the holes in the backside cooling configuration is significantly different when compared to flow exiting the plenum fed holes. We hypothesize that backside cooling configuration has flow exiting the holes in various directions, including laterally, and behaving similar to slot film cooling, explaining the differences in trends. Increasing DR at constant BR shows an increase in adiabatic effectiveness and HTC in both backside cooling and plenum fed configurations due to the decreased momentum of the coolant, making film attachment to the surface more probable. The effects of L/D ratio in this study were negligible since both ratios used were small. This shows that the coolant flow is still underdeveloped at both L/D ratios. The study also showed that increasing turbulence through increasing Reynolds number decreased adiabatic effectiveness.


Author(s):  
Lin Ye ◽  
Cun-liang Liu ◽  
Hai-yong Liu ◽  
Qi-jiao He ◽  
Gang Xie

The trailing edge of the high-pressure turbine blade presents significant challenges to cooling structure design. To achieve better cooling performance at turbine blade trailing edge, a novel ribbed cutback structure is proposed for trailing edge cooling, which has rib structures on the cutback surface for heat transfer enhancement. In this study, numerical simulations have been performed on the effects of V-shaped rib angle on the film cooling characteristics and flow physics. Three V-shaped rib angles of 30°, 45° and 60° are studied. The distributions of adiabatic cooling effectiveness and heat transfer coefficient are obtained under blowing ratios with the value of 0.5, 1.0 and 1.5 respectively. Due to the relatively small rib height, the effect of V-shaped ribs on the film cooling effectiveness is not notable. The disadvantage of V-shaped ribs mainly exhibits at the downstream area of cutback surface. With the increase of V-shaped rib angle, the film cooling effectiveness becomes lower, but the values are still above 0.9. The V-shaped ribs obviously enhance the heat transfer on trailing edge cutback surface. The area-averaged heat transfer coefficient of the V-rib case is higher than that of the smooth case by 26.3–41.2%. The 45° V-rib case has higher heat transfer intensity than the other two V-shaped rib cases under all the three blowing ratios. However, the heat transfer coefficient distribution of the 60° V-rib case is more uniform. The heat transfer intensity of the 30° V-rib case is higher in the downstream region than the other two cases, but lower in the upstream region in which the difference becomes smaller with the increase of blowing ratio. The 45° V-rib case and the 60° V-rib case both reach the maximum value of area-averaged heat transfer intensity under blowing ratio is 1.0. Under higher blowing ratio, the 30° V-rib case and the 45° V-rib case outperform 2.1% and 6.7% higher value relative to the 60° V-rib case respectively due to the smaller velocity gradient in the 60° V-rib case in the downstream.


2012 ◽  
Vol 134 (6) ◽  
Author(s):  
Shiou-Jiuan Li ◽  
Akhilesh P. Rallabandi ◽  
Je-Chin Han

Detailed film cooling effectiveness distributions along a modeled turbine rotor blade under the combined effects of an upstream trailing edge unsteady wake with coolant ejection are presented using the pressure sensitive paint (PSP) mass transfer analogy method. The experiment is conducted in a low speed wind tunnel facility with a five blade linear cascade. The exit Reynolds number based on the axial chord is 370,000. Unsteady wakes and trailing edge coolant jets are produced by a spoked wheel-type wake generator with hollow rods equipped with several coolant ejections from holes. The coolant-to-mainstream density ratios for both the blade and trailing edge coolant ejection range from 1.5 to 2.0 for simulating realistic engine conditions. Blade blowing ratio studies are 0.5 and 1.0 on the suction surface and 1.0 and 2.0 on the pressure surface. The trailing edge jet blowing ratio and Strouhal numbers are 1.0 and 0.12, respectively. The results show that the unsteady wake reduces the overall film cooling effectiveness. However, the unsteady wake with trailing edge coolant ejection enhances the overall effectiveness. The results also show that the overall filming cooling effectiveness increases by using heavier coolant for trailing edge ejection and for blade surface film cooling.


2013 ◽  
Vol 135 (3) ◽  
Author(s):  
S. Xue ◽  
A. Newman ◽  
W. Ng ◽  
H. K. Moon ◽  
L. Zhang

An experimental study was performed to measure surface Nusselt number and film cooling effectiveness on a film cooled first stage nozzle guide vane (NGV) at high freestream turbulence, using a transient thin film gauge (TFG) technique. The information presented attempts to further characterize the performance of shaped hole film cooling by taking measurements on a row of shaped holes downstream of leading edge showerhead injection on both the pressure and suction surfaces (hereafter PS and SS) of a first stage NGV. Tests were performed at engine representative Mach and Reynolds numbers and high inlet turbulence intensity and large length scale at the Virginia Tech 2D Linear Transonic Cascade facility. Three exit Mach/Reynolds number conditions were tested: 1.0/1,400,000, 0.85/1,150,000, and 0.60/850,000 where Reynolds number is based on exit conditions and vane chord. At Mach/Reynolds numbers of 1.0/1,450,000 and 0.85/1,150,000, three blowing ratio conditions were tested: BR = 1.0, 1.5, and 2.0. At a Mach/Reynolds number of 0.60/850,000, two blowing ratio conditions were tested: BR = 1.5 and 2.0. All tests were performed at inlet turbulence intensity of 12% and length scale normalized by the cascade pitch of 0.28. Film cooling effectiveness and heat transfer results compared well with previously published data, showing a marked effectiveness improvement (up to 2.5×) over the showerhead-only NGV and also agreement with published showerhead-shaped hole data. Net heat flux reduction (NHFR) was shown to increase substantially (average 2.6 × ) with the addition of shaped holes with an increase (average 1.6×) in required coolant mass flow. Based on the heat flux data, the boundary layer transition location was shown to be within a consistent region on the suction side regardless of blowing ratio and exit Mach number.