Evaluation of an Uncooled Focal Plane Array Infrared Camera for Effusion Cooling Research

Author(s):  
Scott K. McGhee ◽  
A. M. Birk

This study assessed a low-cost, uncooled ferroelectric detector infrared camera for effusion cooling research. Advances in uncooled IR technology have led to applications previously limited to research-grade cameras. The imager operated in the 7–14μm waveband and sampled up to 30 frames per second. Thermal images were made of a matte-black flat plate, downstream of two cylindrical jets with injection angles of α = 30° and 90°, and L/D = 6. Thermocouple calibration was specific to each image. Statistical analysis and image analysis yielded detailed temperature maps with uncertainty as small as 0.9°C, a spatial resolution of 0.4mm, and a sensitivity of 0.1 °C. The system compared favorably with established infrared systems. Advantages include minimal instrumentation, on-line results, and a high degree of accuracy and resolution, at significantly reduced cost.

1989 ◽  
Vol 23 (1) ◽  
pp. 39-42
Author(s):  
L. S. Young ◽  
R. J. East ◽  
T. Fearn

A system comprising a suite of 4 computer programs has been developed for on-line rodent weight data collection and statistical analysis using an IBM personal computer. Data can be collected from up to 3 separate trials simultaneously, and can be stored for later statistical analysis. Mettler balances were used for the animal weighing. A Mettler current loop adapter and a multiplexer were used to interface the balances with the computer.


Author(s):  
W.J. de Ruijter ◽  
P. Rez ◽  
David J. Smith

There is growing interest in the on-line use of computers in high-resolution electron n which should reduce the demands on highly skilled operators and thereby extend the r of the technique. An on-line computer could obviously perform routine procedures hand, or else facilitate automation of various restoration, reconstruction and enhan These techniques are slow and cumbersome at present because of the need for cai micrographs and off-line processing. In low resolution microscopy (most biologic; primary incentive for automation and computer image analysis is to create a instrument, with standard programmed procedures. In HREM (materials researc computer image analysis should lead to better utilization of the microscope. Instru (improved lens design and higher accelerating voltages) have improved the interpretab the level of atomic dimensions (approximately 1.6 Å) and instrumental resolutior should become feasible in the near future.


2010 ◽  
Author(s):  
Wendy L. Sarney ◽  
John W. Little ◽  
Kimberley A. Olver ◽  
Frank E. Livingston ◽  
Krisztian Niesz ◽  
...  

2020 ◽  
Vol 18 (1) ◽  
pp. 303-313 ◽  
Author(s):  
Aamir Rasheed ◽  
Tahseen Ghous ◽  
Sumaira Mumtaz ◽  
Muhammad Nadeem Zafar ◽  
Kalsoom Akhter ◽  
...  

AbstractIn the present work, a novel continuous flow system (CFS) is developed for the preconcentration and determination of Cr (VI) using Pseudomonas aeruginosa static biomass immobilized onto an effective and low-cost solid support of powdered eggshells. A mini glass column packed with the immobilized biosorbent is incorporated in a CFS for the preconcentration and determination of Cr (VI) from aqueous solutions. The method is based on preconcentration, washing and elution steps followed by colorimetric detection with 1,5-diphenyl carbazide in sulphuric acid. The effects of several variables such as pH, retention time, flow rate, eluent concentration and loaded volume are studied. Under optimal conditions, the CFS method has a linear range between 10 and 100 μg L-1 and a detection limit of 6.25 μg L-1 for the determination of Cr (VI). The sampling frequency is 10 samples per hour with a preconcentration time of 5 mins. Furthermore, after washing with a 0.1 M buffer (pH 3.0), the activity of the biosorbent is regenerated and remained comparable for more than 200 cycles. Scanning electron microscopy reveals a successful immobilization of biomass on eggshells powder and precipitation of Cr (VI) on the bacterial cell surface. The proposed method proves highly sensitive and could be suitable for the determination of Cr (VI) at an ultra-trace level.


2021 ◽  
Vol 11 (15) ◽  
pp. 6885
Author(s):  
Marcos D. Fernandez ◽  
José A. Ballesteros ◽  
Angel Belenguer

Empty substrate integrated coaxial line (ESICL) technology preserves the many advantages of the substrate integrated technology waveguides, such as low cost, low profile, or integration in a printed circuit board (PCB); in addition, ESICL is non-dispersive and has low radiation. To date, only two transitions have been proposed in the literature that connect the ESICL to classical planar lines such as grounded coplanar and microstrip. In both transitions, the feeding planar lines and the ESICL are built in the same substrate layer and they are based on transformed structures in the planar line, which must be in the central layer of the ESICL. These transitions also combine a lot of metallized and non-metallized parts, which increases the complexity of the manufacturing process. In this work, a new through-wire microstrip-to-ESICL transition is proposed. The feeding lines and the ESICL are implemented in different layers, so that the height of the ESICL can be independently chosen. In addition, it is a highly compact transition that does not require a transformer and can be freely rotated in its plane. This simplicity provides a high degree of versatility in the design phase, where there are only four variables that control the performance of the transition.


2013 ◽  
Vol 551 ◽  
pp. 143-160 ◽  
Author(s):  
Ajit Pal Singh ◽  
Brian Gabbitas ◽  
De Liang Zhang

Powder metallurgy (PM) is potentially capable of producing homogeneous titanium alloys at relative low cost compared to ingot metallurgy (IM). There are many established PM methods for consolidating metal powders to near net shapes with a high degree of freedom in alloy composition and resulting microstructural characteristics. The mechanical properties of titanium and its alloys processed using a powder metallurgical route have been studied in great detail; one major concern is that ductility and toughness of materials produced by a PM route are often lower than those of corresponding IM materials. The aim of this paper is to review the fracture toughness of both PM and IM titanium alloys. The effects of critical factors such as interstitial impurities, microstructural features and heat treatment on fracture toughness are also discussed


Sign in / Sign up

Export Citation Format