Experimental Study of Municipal Solid Waste (MSW) Incineration and Its Flue Gas Purification

Author(s):  
Zhaoping Zhong ◽  
Basheng Jin ◽  
Jixiang Lan ◽  
Changqing Dong ◽  
Hongchang Zhou

This paper presents experimental study of fluidized absorption process for flue gas purification of co-combustion of municipal solid waste (MSW) and coal in a circulating fluidized bed Combustor (CFBC) test rig. The test rig is composed of a CFBC, coal/MSW feeding subsystem, ash cycle subsystem and flue gas purification subsystem. In the circulating fluidized bed, section area of fluidized bed is 230mm × 230mm and the freeboard is 460mm × 395mm. The total height of the test facility is 8m; height of bed and freeboard are 1.5m and 6m respectively. The preheated air enters the bed as primary air passing through distributor and provides oxygen for combustion. Six movable tubes immerged within the bed are used in adjusting the bed temperature. The cyclone separator is fixed up at the exit of chamber. The separated ashes return to chamber through the recycling feeder for decreasing the carbon content in fly ash and promoting the combustion efficiency. The flue gas from the exit of cyclone separator enters the air preheater to preheat the cold air at first, then enters the flue gas purification facility, finally be discharged into air by induced drafted fan passing through the stack. Coal is carried to a positive pressure feeding entrance by screw feeder and enters the bed. Secondary air is injected into a sealed end feeding pipe under MSW feeder, for enhancing the mixture in furnace, providing the oxygen for combustion and preventing from MSW remaining in the feeding pipe. The material of bed is silicon sand. Fluidized absorption facility for flue gas purification in MSW incineration is mainly composed of humidification system, absorption tower, flue gas reheater, fabric filter, slurry making pool, sediment pool and measurement subsystem. The temperature of flue gas from boiler by induced draft fan reduces to 120°C when flue gas enters the humidification region, which can increase the ability of acid gas absorption and prevent the slurry evaporation. When flue gas and limestone slurry enter the absorption tower, the three-phase material of gas, liquid and solid generates intense mixing and forms bubbling layer. The acid gases in flue gas are absorbed by limestone slurry, and a large amount of dusts are collected in reaction tank. Feeding oxidation air into slurry and agitating slurry simultaneously so as to promote the inner circulation of slurry and oxygenization of calcium sulphite. Flue gas passes through undulate demister which has high efficiency and low resistance, then enters fabric filter after reheating, finally be discharged into the stack by induced draft fan. The mixture of slurry and gypsum is emitted into the sediment pool through bottom and clear liquid in sediment pool returns to slurry making pool or absorption tower. The test results are as follows: the combustion efficiency is greater than 95%, the carbon content of fly ash is lower than 8%, and the loss of slag combustion is lower than 5%. When sorbent is limestone slurry, the concentration of slurry is 1%, the circulating ratio is 3, the jet rate is 5∼15m/s. The immerged depth of bubbling pipe under the slurry is 140mm. In the fluidized absorption facility for flue gas purification of MSW incineration, the desulfurization efficiency is >90%, the de-nitrification efficiency is 20∼30%, the de-chlorination efficiency is >80%, the removal efficiency of dust, heavy metal and dioxins are >99%, >98.6% and 99.35% respectively. After passing through fluidized absorption facility for flue gas purification of MSW incineration, when the concentration of O2 is 11%, the emission concentration of every components in flue gas are: SO2 is 20∼50mg/Nm3, NOx is 130∼270 mg/Nm3, HCl is 7∼12 mg/Nm3, HF is ∼8 mg/Nm3, CO2 is7∼8%, dust is 23∼67 mg/Nm3, Cr is 0.2172 mg/Nm3, Cu is 0.0454 mg/Nm3, Pb is 0.2963 mg/Nm3, Zn is 0.2074 mg/Nm3, Fe is 2.834 mg/Nm3, As is 1.112 × 10−3 mg/Nm3, Hg is 2.38 × 10−4 mg/Nm3 and dioxins is 0.1573 ng/Nm3. These emission concentrations are all lower than the Chinese emission standards. Some of them come close to the emission standards of developed country.

2020 ◽  
Vol 9 (1) ◽  
pp. 1156-1165

This paper presents an experimental investigation on circulating fluidized bed (CFB) combustion of one of agricultural wastes (faba bean hulls) and co-combustion faba bean hulls and Egyptian (Sinai) coal. The test rig is a pilot scale CFB combustor of 145 mm inner diameter, 2 m tall and 100 kW thermal capacity. The influences of excess air, degree of air staging, bean hull particle size and coal share were studied. Temperature, heat flux, CO, NOx and SO2 concentrations along the reactor height and flue gas out from cyclone were measured. The combustion efficiency was calculated based on CO emission and unburned char in flue gas. The results showed that size reduction of bean hulls results in lower CO and NOx emissions. The induction of secondary air has a negative effect on combustion efficiency. The highest efficiency recorded for bean hulls combustion was 98.5% at excess air ratio (EA) =1.09 without secondary air. Co-combustion of Sinai coal and bean hulls reduced CO and NOx emissions but increased SO2 emissions. The results suggest that bean hulls are potential fuel that can be utilized for efficient and clean energy production by using CFB combustion system especially at co-combustion.


Author(s):  
S. V. Plashykhin ◽  
T. V. Bojko ◽  
D. N. Skladannyy ◽  
Ju. A. Zaporozhets ◽  
Artem S. Safiants

Energies ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 2174
Author(s):  
Marta Marczak-Grzesik ◽  
Stanisław Budzyń ◽  
Barbara Tora ◽  
Szymon Szufa ◽  
Krzysztof Kogut ◽  
...  

The research presented by the authors in this paper focused on understanding the behavior of mercury during coal combustion and flue gas purification operations. The goal was to determine the flue gas temperature on the mercury emissions limits for the combustion of lignites in the energy sector. The authors examined the process of sorption of mercury from flue gases using fine-grained organic materials. The main objectives of this study were to recommend a low-cost organic adsorbent such as coke dust (CD), corn straw char (CS-400), brominated corn straw char (CS-400-Br), rubber char (RC-600) or granulated rubber char (GRC-600) to efficiently substitute expensive dust-sized activated carbon. The study covered combustion of lignite from a Polish field. The experiment was conducted at temperatures reflecting conditions inside a flue gas purification installation. One of the tested sorbents—tire-derived rubber char that was obtained by pyrolysis—exhibited good potential for Hg0 into Hg2+ oxidation, resulting in enhanced mercury removal from the flue. The char characterization increased elevated bromine content (mercury oxidizing agent) in comparison to the other selected adsorbents. This paper presents the results of laboratory tests of mercury sorption from the flue gases at temperatures of 95, 125, 155 and 185 °C. The average mercury content in Polish lignite was 465 μg·kg−1. The concentration of mercury in flue gases emitted into the atmosphere was 17.8 µg·m−3. The study analyzed five low-cost sorbents with the average achieved efficiency of mercury removal from 18.3% to 96.1% for lignite combustion depending on the flue gas temperature.


Vestnik MEI ◽  
2021 ◽  
Vol 2 (2) ◽  
pp. 11-19
Author(s):  
Anton N. Efremov ◽  
◽  
Aleksey A. Dudolin ◽  

The existing method for selecting the structure of a power plant for thermally recycling municipal solid waste (MSW) in the Russian Federation does not address the matter of selecting all components of an energy complex operating on MSW, but places focus on determining the best accessible waste thermal neutralization technology. This generates the need to search for new methods and to select criteria of choosing the structure for each particular project. A comparative analysis of various structural schemes of waste-to-energy plants widely used outside of Russia will make it possible to reveal their main advantages and drawbacks, and to determine their application fields. The article describes the statistical indicators characterizing the operation of the flue gas purification system from acid gases, which can be applied in performing a feasibility study, intellectual property assessment, and in carrying out front-end engineering. For waste-to-energy plants constructed in an urban environment and aimed to operate with keeping to a minimum the gross emissions of acid gases into the atmospheric air, the use of a wet reactor system is recommended, which will ensure low emissions of HF, HCl, and SOx. The system with a wet reactor will make it possible to reduce gross emissions of harmful substances during the operation of large capacity waste-to-energy power plants and will be a justified choice in such case. In constructing medium capacity waste-to-energy plants (with a throughput of up to 350 000 t of MSW per annum), semi-dry and dry reactors can be used; for such plants, the technology involving the use of a semi-dry reactor is the most preferred one.


2013 ◽  
Vol 39 (1) ◽  
pp. 847-851 ◽  
Author(s):  
Zeming He ◽  
Kjeld Bøhm Andersen ◽  
Frederik Berg Nygaard ◽  
Kent Kammer Hansen

Author(s):  
Han-Ping Chen ◽  
Xian-Hua Wang ◽  
Shi-Hong Zhang ◽  
De-Chang Liu ◽  
Yu-Hua Lai ◽  
...  

In China, there are a large number of pulverized coal-fired industrial boilers, whose steam capacities are usually relatively small. These boilers can burn only high-grade coal and have low combustion efficiency. Furthermore, the combustion emissions, such as SO2 and NOx, pollute the environment severely. Therefore it is very important and urgent to adopt economically efficient and environmentally friendly technologies to retrofit these boilers. At the same time, there are many industrial wastes, such as bagasse, wood waste, rubbish, petroleum coke and so on, need burning disposal in China. Fluidized bed combustion technology is a kind of clear combustion technology, which has many advantages, such as excellence fuel flexibility, high combustion efficiency, low pollutant emission and good turndown capability etc. So, adopting fluidized bed combustion technology, retrofitting pulverized coal-fired boiler into fluidized bed boiler can realize pure burning various wastes or co-firing with coal, which should have great economic benefits and social benefits. And the application prospect of the method is also extensive. The State Key Laboratory of Coal Combustion has successfully retrofitted a 25t/h pulverized coal-fired boiler into circulating fluidized bed boiler with in-bed tubes and downward exhaust cyclone. The retrofitted boiler can burn mixture of coal and bagasse and the steam capacity reaches 35t/h. This paper presents the retrofitting measures and the operation status of the boiler after retrofitting.


Sign in / Sign up

Export Citation Format

Share Document