CFD Optimization of Gas-Side Flow Channel Configuration Inside a High Temperature Bayonet Tube Heat Exchanger With Inner and Outer Fins

Author(s):  
T. Ma ◽  
Y. P. Ji ◽  
M. Zeng ◽  
Q. W. Wang

In this paper, the gas-side fluid flow distribution inside a bayonet tube heat exchanger with inner and outer fins is numerically studied. The heat exchanger is designed based on the traditional bayonet tube heat exchanger, where compact continuous plain fins and wave-like fins are mounted on the outside and inside surfaces of outer tubes, respectively, to enhance the heat transfer performance. However, gross flow maldistribution and large vortices are observed in the gas-side flow channel of baseline design. In order to improve the flow uniformity, three modified designs are proposed. Three vertical plates and two inclined plates are mounted on the inlet manifold for Model B. For the Model C, another six bending plates are mounted on the middle manifolds and three pairs of them are connected together. The Model D has a similar structure as Model C except for the two additional baffles. The results indicate that the flow distributions of Model C and D are much more uniform under different inlet Reynolds number, especially in the high inlet Reynolds number. Although the flow distribution of Model D is the best, its pressure drop is 2.6 times higher than that of Model C. Therefore, the design of Model C is the most optimized structure. Compared with the original design, the nonuniformity of Model C can be reduced by 42% while the pressure drop is almost the same under the baseline condition.

Author(s):  
Ting Ma ◽  
Min Zeng ◽  
Yanpeng Ji ◽  
Qiuwang Wang

In this paper, the gas-side fluid flow distribution inside a bayonet tube heat exchanger with inner and outer fins is numerically studied. The heat exchanger is designed based on the traditional bayonet tube heat exchanger, where compact continuous plain fins and wavelike fins are mounted on the outside and inside surfaces of outer tubes, respectively, to enhance the heat transfer performance. However, gross flow maldistribution and large vortices are observed in the gas-side flow channel of baseline design. In order to improve the flow uniformity, three modified designs are proposed. Three vertical plates and two inclined plates are mounted on the inlet manifold for Model B. For the Model C, another six bending plates are mounted on the middle manifolds and three pairs of them are connected together. The Model D has a similar structure as Model C except for the two additional baffles. The results indicate that the flow distributions of Models C and D are much more uniform under different inlet Reynolds number, especially in the high inlet Reynolds number. Although the flow distribution of Model D is the best, its pressure drop is 2.6 times higher than that of Model C. Therefore, the design of Model C is the most optimized structure. Compared with the original design, the nonuniformity of Model C can be reduced by 42% while the pressure drop is almost the same under the baseline condition.


2013 ◽  
Vol 860-863 ◽  
pp. 754-757
Author(s):  
Can Zheng ◽  
Fei Wang ◽  
Yong Gang Lei

A new type of helical baffles heat exchanger is presented in this paper. Comparative study, through numerical simulation, was undertook between the new helical baffles heat exchanger and segmental baffle board heat exchanger in shell side flow and heat exchange characteristics. Fluid medium in the shell side is air. At the same velocity in the same flow conditions, pressure drop of helical baffles heat exchangers fell by an average of 26.8% compared with segmental baffle board heat exchangers, and the unit pressure drop of the heat transfer ratio of helical baffles heat exchanger increased by an average of 40.6%.


Symmetry ◽  
2020 ◽  
Vol 12 (10) ◽  
pp. 1652
Author(s):  
Mehdi Ghalambaz ◽  
Ramin Mashayekhi ◽  
Hossein Arasteh ◽  
Hafiz Muhammad Ali ◽  
Pouyan Talebizadehsardari ◽  
...  

This paper investigates the convective heat transfer in a heat exchanger equipped with twisted tape elements to examine effects of the twisted tape truncation percentage, pitch value, position and Reynolds number using 3D numerical simulation. A symmetric heat flux is applied around the tube as the studied heat exchanger. Based on the influences in both heat transfer enhancement and pressure drop, the performance evaluation criterion (PEC) is utilized. Inserting twisted tape elements and reducing the pitch value significantly augment the Nusselt number, friction coefficient and PEC number compared to the plain tube. For the best case with a Reynolds number of 1000, the average Nusselt number increases by almost 151%, which is the case of fully fitted twisted tape at a pitch value of L/4. Moreover, increasing the twisted tape truncation percentage reduces both heat transfer and pressure drop. Furthermore, the highest heat transfer rate is achieved when the truncated twisted tape is located at the entrance of the tube. Finally, it is concluded that for P = L, L/2, L/3 and L/4, the optimum cases from the viewpoint of energy conservation are twisted tapes with truncation percentages of 75, 50, 50 and 0%, in which the related PEC numbers at a Reynolds number of 1000 are almost equal to 1.08, 1.24, 1.4 and 1.76, respectively.


Energies ◽  
2020 ◽  
Vol 14 (1) ◽  
pp. 62
Author(s):  
Muhammed Saeed ◽  
Khaled Alawadi ◽  
Sung Chul Kim

Since printed circuit heat exchangers (PCHE) are the largest modules of a supercritical carbon dioxide Brayton cycle, they can considerably affect the whole system’s performance and layout. Straight-channel and zigzag-channel printed circuit heat exchangers have frequently been analyzed in the standalone mode and repeatedly proposed for sCO2−BC. However, the impact of heat exchanger designs with straight and zigzag-channel configurations on the performance of the cycle and its components, i.e., the turbine and compressor, has not been studied. In this context, this study evaluates the effect of different heat exchanger designs with various values of effectiveness (ϵ), inlet Reynolds number (Re), and channel configuration (zigzag and straight channel) on the overall performance of the sCO2−BC and its components. For the design and analysis of PCHEs, an in-house PCHE design and analysis code (PCHE-DAC) was developed in the MATLAB environment. The sCO2−BC performance was evaluated utilizing an in-house cycle simulation and analysis code (CSAC) that employs the heat exchanger design code as a subroutine. The results suggest that pressure drop in PCHEs with straight-channel configuration is up to 3.0 times larger than in PCHEs with zigzag-channel configuration. It was found that a higher pressure drop in the PCHEs with straight channels can be attributed to substantially longer channel lengths required for these designs (up to 4.1 times than zigzag-channels) based on the poor heat transfer characteristics associated with these channel geometries. Thus, cycle layouts using PCHEs with a straight-channel configuration impart a much higher load (up to 1.13 times) on the recompression compressor, this in turn, results in a lower pressure ratio across the turbine. Therefore, the overall performance of the sCO2−BC using PCHEs with straight-channel configurations is found to be substantially inferior to that of layouts using PCHEs with zigzag-channel configurations. Finally, optimization results suggest that heat exchanger’s design with inlet Reynolds number and heat exchanger effectiveness ranging from 32 k to 42 k and 0.94>ϵ>0.87, respectively, are optimal for sCO2−BC and present a good bargain between cycle efficiency and its layout size.


CFD letters ◽  
2020 ◽  
Vol 12 (11) ◽  
pp. 37-60
Author(s):  
Mohammadreza Hasandust Rostami ◽  
Barat Ghobadian ◽  
Gholamhassan Najafi ◽  
Ali Motevali ◽  
Nor Azwadi Che Sidik

In this research, the thermal attributes of shell and finned tube heat exchanger such as thermal efficiency, pressure drop, heat transfer rate and average temperature in the tube side of heat exchanger with using the different volume concentration of nanoparticles (SWCNT and Graphene quantum dot) at the various Reynolds number by applying either fin blades and without fin blades have been conducted numerically. In this heat exchanger the hot fluid or nanofluid flows in the tube section and cold fluid or pure water moves in the shell side. As regarding to results obtained the majority of thermal characteristics like heat transfer rate, pressure drop and effectiveness enhanced with augmentation of Reynolds number and increasing of volume concentration of nanofluids to 1% volumetric of working fluid whereas at the higher volume concentrations of nanoparticles (upper from 1% volumetric) the thermal properties of heat exchanger decreased generally. Also pressure drop intensifies with increment of Reynolds number and volume concentration of nanoparticles that at higher Reynolds number the effects of nanoparticles on the pressure drop were more noticeable. The average temperature of heat exchanger in the end section of inside tubes increased with augmentation of Reynolds number and nanoparticles. Finally, according to the results obtained in this study, most impression on the thermal attributes enhancement was found by employing of finned tubes compared to other factor which this factor increased heat transfer rate of heat exchanger by almost 188% also the effects of nanoparticles at the high levels of volume concentration especially for 5% of SWCNT nanoparticle on the pressure drop obtained about 80% compared to the base fluid.


Author(s):  
Zhuo Yang ◽  
Tariq Amin Khan ◽  
Wei Li ◽  
Hua Zhu ◽  
Zhijian Sun ◽  
...  

The flow field inside the heat exchangers is associated with maximum heat transfer and minimum pressure drop. Designing a compact heat exchanger and employing various techniques to enhance its overall performance has been widely investigated and still an active research field. However, few researches deal with thermal optimization. The application of elliptic tube is an effective alternative to circular tube which can reduce the pressure drop significantly. In this study, numerical simulation and optimization of variable tube ellipticity is studied at low Reynolds numbers. The three-dimensional numerical analysis and a multi-objective genetic algorithm (MOGA) with surrogate modelling is performed. Two row tubes in staggered arrangement in fin-and-tube heat exchanger is investigated for combination of various elliptic ratio (e = minor axis/major axis) and Reynolds number. Tube elliptic ratio ranges from 0.2 to 1 and Reynolds number ranges from 150 to 750. The tube perimeters are kept constant while changing the elliptic ratio. The numerical model is derived based on continuum flow approach and steady-state conservation equations of mass, momentum and energy. The flow is assumed as incompressible and laminar due to low inlet velocity. Results are presented in the form of Colburn factor, friction factor, temperature contours and streamline contours. Results show that increasing elliptic ratio increases the friction factor due increased flow blocking area, however, the effect on the Colburn factor is not significant. Moreover, tube with lower elliptic ratio followed by higher elliptic ratio tube has better thermal-hydraulic performance. To achieve maximum heat transfer enhancement and minimum pressure drop, the Pareto optimal strategy is adopted for which the CFD results, Artificial neural network (ANN) and MOGA are combined. The tubes elliptic ratio (0.2 ⩽ e ⩽ 1.0) and Reynolds number (150 ⩽ Re ⩽ 750) are the design variables. The objective functions include Colburn factor (j) and friction factor (f). The CFD results are input into ANN model. Once the ANN is computed and its accuracy is checked, it is then used to estimate the model responses as a function of inputs. The final trained ANN is then used to drive the MOGA to obtain the Pareto optimal solution. The optimal values of these parameters are finally presented.


2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Swanand Gaikwad ◽  
Ashish Parmar

AbstractHeat exchangers possess a significant role in energy transmission and energy generation in most industries. In this work, a three-dimensional simulation has been carried out of a shell and tube heat exchanger (STHX) consisting of segmental baffles. The investigation involves using the commercial code of ANSYS CFX, which incorporates the modeling, meshing, and usage of the Finite Element Method to yield numerical results. Much work is available in the literature regarding the effect of baffle cut and baffle spacing as two different entities, but some uncertainty pertains when we discuss the combination of these two parameters. This study aims to find an appropriate mix of baffle cut and baffle spacing for the efficient functioning of a shell and tube heat exchanger. Two parameters are tested: the baffle cuts at 30, 35, 40% of the shell-inside diameter, and the baffle spacing’s to fit 6,8,10 baffles within the heat exchanger. The numerical results showed the role of the studied parameters on the shell side heat transfer coefficient and the pressure drop in the shell and tube heat exchanger. The investigation shows an increase in the shell side heat transfer coefficient of 13.13% when going from 6 to 8 baffle configuration and a 23.10% acclivity for the change of six baffles to 10, for a specific baffle cut. Evidence also shows a rise in the pressure drop with an increase in the baffle spacing from the ranges of 44–46.79%, which can be controlled by managing the baffle cut provided.