Study on the Effect of Inlet Geometry on the Noise of an Axial Fan, With Involvement of the Phased Array Microphone Technique

Author(s):  
Tamás Benedek ◽  
János Vad

The paper presents a comparative case study in which a free-inlet, free-outlet industrial ventilating fan has been equipped with various inlet geometries. The original short-tapered entry has been replaced by a standardized bellmouth entry, resulting in remarkable noise reduction. The experimentation presented herein is adaptable to industrial onsite diagnostics. The upstream-radiated broadband noise associated with rotating sources has been mapped in a spatially resolved manner, by means of a Phased Array Microphone system and a Rotating Source Identifier beamforming algorithm. The acoustic measurements have been supplemented with aerodynamic measurements on the inlet velocity profile, and with Computational Fluid Dynamics studies. The acoustic data have been processed for enabling their evaluation in association with the aerodynamic operation of the elemental rotor cascades in a two-dimensional approach, and also for their interpretation in relationship to three-dimensional flow phenomena such as tip leakage flow. For this purpose, the acoustic data have been presented in the form of circumferentially-averaged noise profiles along the blade span, as well as noise source imaging maps. The studies reveal the following acoustic benefits of reconfiguring the original short-tapered entry to the bellmouth entry. A peripheral separation zone is characteristic for the short-tapered entry, provoking double-leakage tip clearance flow, being the dominant source of noise at higher frequencies. Such a peripheral separation zone is suppressed by the bellmouth inlet, and thus, the double-leakage flow and the related noise is eliminated. Farther away from the tip, along the dominant portion of the span, the moderation of endwall blockage due to suppressing the peripheral separation zone has led to the reduction of the rotor inlet velocity, thus moderating the noise associated with the suction side boundary layer developing on the blades.

Energies ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 4168
Author(s):  
Botao Zhang ◽  
Xiaochen Mao ◽  
Xiaoxiong Wu ◽  
Bo Liu

To explain the effect of tip leakage flow on the performance of an axial-flow transonic compressor, the compressors with different rotor tip clearances were studied numerically. The results show that as the rotor tip clearance increases, the leakage flow intensity is increased, the shock wave position is moved backward, and the interaction between the tip leakage vortex and shock wave is intensified, while that between the boundary layer and shock wave is weakened. Most of all, the stall mechanisms of the compressors with varying rotor tip clearances are different. The clearance leakage flow is the main cause of the rotating stall under large rotor tip clearance. However, the stall form for the compressor with half of the designed tip clearance is caused by the joint action of the rotor tip stall caused by the leakage flow spillage at the blade leading edge and the whole blade span stall caused by the separation of the boundary layer of the rotor and the stator passage. Within the investigated varied range, when the rotor tip clearance size is half of the design, the compressor performance is improved best, and the peak efficiency and stall margin are increased by 0.2% and 3.5%, respectively.


Author(s):  
Rubén Bruno Díaz ◽  
Jesuino Takachi Tomita ◽  
Cleverson Bringhenti ◽  
Francisco Carlos Elizio de Paula ◽  
Luiz Henrique Lindquist Whitacker

Abstract Numerical simulations were carried out with the purpose of investigating the effect of applying circumferential grooves at axial compressor casing passive wall treatment to enhance the stall margin and change the tip leakage flow. The tip leakage flow is pointed out as one of the main contributors to stall inception in axial compressors. Hence, it is of major importance to treat appropriately the flow in this region. Circumferential grooves have shown a good performance in enhancing the stall margin in previous researches by changing the flow path in the tip clearance region. In this work, a passive wall treatment with four circumferential grooves was applied in the transonic axial compressor NASA Rotor 37. Its effect on the axial compressor performance and the flow in the tip clearance region was analyzed and set against the results attained for the smooth wall case. A 2.63% increase in the operational range of the axial compressor running at 100%N, was achieved, when compared with the original smooth wall casing configuration. The grooves installed at compressor casing, causes an increase in the flow entropy generation due to the high viscous effects in this gap region, between the rotor tip surface and casing with grooves. These viscous effects cause a drop in the turbomachine efficiency. For the grooves configurations used in this work, an efficiency drop of 0.7% was observed, compared with the original smooth wall. All the simulations were performed based on 3D turbulent flow calculations using Reynolds Averaged Navier-Stokes equations, and the flow eddy viscosity was determined using the two-equation SST turbulence model. The details of the grooves geometrical dimensions and its implementation are described in the paper.


Author(s):  
Wei Li ◽  
Wei-Yang Qiao ◽  
Kai-Fu Xu ◽  
Hua-Ling Luo

The tip leakage flow has significant effects on turbine in loss production, aerodynamic efficiency, etc. Then it’s important to minimize these effects for a better performance by adopting corresponding flow control. The active turbine tip clearance flow control with injection from the tip platform is given in Part-1 of this paper. This paper is Part-2 of the two-part papers focusing on the effect of five different passive turbine tip clearance flow control methods on the tip clearance flow physics, which consists of a partial suction side squealer tip (Partial SS Squealer), a double squealer tip (Double Side Squealer), a pressure side tip shelf with inclined squealer tip on a double squealer tip (Improved PS Squealer), a tip platform extension edge in pressure side (PS Extension) and in suction side (SS Extension) respectively. Combined with the turbine rotor and the numerical method mentioned in Part 1, the effects of passive turbine tip clearance flow controls on the tip clearance flow were sequentially simulated. The detailed tip clearance flow fields with different squealer rims were described with the streamline and the velocity vector in various planes parallel to the tip platform or normal to the tip leakage vortex core. Accordingly, the mechanisms of five passive controls were put in evidence; the effects of the passive controls on the turbine efficiency and the tip clearance flow field were highlighted. The results show that the secondary flow loss near the outer casing including the tip leakage flow and the casing boundary layer can be reduced in all the five passive control methods. Comparing the active control with the passive control, the effect brought by the active injection control on the tip leakage flow is evident. The turbine rotor efficiency could be increased via the rational passive turbine tip clearance flow control. The Improved PS Squealer had the best effect on turbine rotor efficiency, and it increased by 0.215%.


1993 ◽  
Author(s):  
S. Kang ◽  
C. Hirsch

Tip leakage flow in a linear compressor cascade of NACA 65-1810 profiles is investigated, for tip clearance levels of 1.0, 2.0 and 3.25 percent of chord at design and off-design flow conditions. Data, velocity and pressures, are collected from three transverse sections inside tip clearance and sixteen sections within flow passage. Tip separation vortex influence is identified from the data. Leakage flow mixing is clearly present inside the clearance and has a significant influence on the internal loss.


Author(s):  
Ali Akturk ◽  
Cengiz Camci

Ducted fans that are popular choices in vertical take-off and landing (VTOL) unmanned aerial vehicles (UAV) offer a higher static thrust/power ratio for a given diameter than open propellers. Although ducted fans provide high performance in many VTOL applications, there are still unresolved problems associated with these systems. Fan rotor tip leakage flow is a significant source of aerodynamic loss for ducted fan VTOL UAVs and adversely affects the general aerodynamic performance of these vehicles. The present study utilized experimental and computational techniques in a 22″ diameter ducted fan test system that has been custom designed and manufactured. Experimental investigation consisted of total pressure measurements using Kiel total pressure probes and real time six-component force and torque measurements. The computational technique used in this study included a 3D Reynolds-Averaged Navier Stokes (RANS) based CFD model of the ducted fan test system. RANS simulations of the flow around rotor blades and duct geometry in the rotating frame of reference provided a comprehensive description of the tip leakage and passage flow. The experimental and computational analysis performed for various tip clearances were utilized in understanding the effect of the tip leakage flow on aerodynamic performance of ducted fans used in VTOL UAVs. The aerodynamic measurements and results of the RANS simulations showed good agreement especially near the tip region.


Author(s):  
J. Luo ◽  
B. Lakshminarayana

The 3-D viscous flowfield in the rotor passage of a single-stage turbine, including the tip-leakage flow, is computed using a Navier-Stokes procedure. A grid-generation code has been developed to obtain embedded H grids inside the rotor tip gap. The blade tip geometry is accurately modeled without any “pinching”. Chien’s low-Reynolds-number k-ε model is employed for turbulence closure. Both the mean-flow and turbulence transport equations are integrated in time using a four-stage Runge-Kutta scheme. The computational results for the entire turbine rotor flow, particularly the tip-leakage flow and the secondary flows, are interpreted and compared with available data. The predictions for major features of the flowfield are found to be in good agreement with the data. Complicated interactions between the tip-clearance flows and the secondary flows are examined in detail. The effects of endwall rotation on the development and interaction of secondary and tip-leakage vortices are also analyzed.


Entropy ◽  
2018 ◽  
Vol 21 (1) ◽  
pp. 21 ◽  
Author(s):  
Hui Li ◽  
Xinrong Su ◽  
Xin Yuan

In unshrouded turbine rotors, the tip leakage vortices develop and interact with the passage vortices. Such complex leakage flow causes the major loss in the turbine stage. Due to the complex turbulence characteristics of the tip leakage flow, the widely used Reynolds Averaged Navier–Stokes (RANS) approach may fail to accurately predict the multi-scale turbulent flow and the related loss. In order to effectively improve the turbine efficiency, more insights into the loss mechanism are required. In this work, a Delayed Detached Eddy Simulation (DDES) study is conducted to simulate the flow inside a high pressure turbine blade, with emphasis on the tip region. DDES results are in good agreement with the experiment, and the comparison with RANS results verifies the advantages of DDES in resolving detailed flow structures of leakage flow, and also in capturing the complex turbulence characteristics. The snapshot Proper Orthogonal Decomposition (POD) method is used to extract the dominant flow features. The flow structures and the distribution of turbulent kinetic energy reveal the development of leakage flow and its interaction with the secondary flow. Meanwhile, it is found that the separation bubble (SB) is formed in tip clearance. The strong interactions between tip leakage vortex (TLV) and the up passage vortex (UPV) are the main source of unsteady effects which significantly enhance the turbulence intensity. Based on the DDES results, loss analysis of tip leakage flow is conducted based on entropy generation rates. It is found that the viscous dissipation loss is much stronger than heat transfer loss. The largest local loss occurs in the tip clearance, and the interaction between the leakage vortex and up passage vortex promotes the loss generation. The tip leakage flow vortex weakens the strength of up passage vortex, and loss of up passage flow is reduced. Comparing steady and unsteady effects to flow field, we found that unsteady effects of tip leakage flow have a large influence on flow loss distribution which cannot be ignored. To sum up, the current DDES study about the tip leakage flow provides helpful information about the loss generation mechanism and may guide the design of low-loss blade tip.


2019 ◽  
Vol 141 (12) ◽  
Author(s):  
D. Tate Fanning ◽  
Steven E. Gorrell ◽  
Daniel Maynes ◽  
Kerry Oliphant

Inducers are used as a first stage in pumps to minimize cavitation and allow the pump to operate at lower inlet head conditions. Inlet flow recirculation or backflow in the inducer occurs at low flow conditions and can lead to instabilities and cavitation-induced head breakdown. Backflow of an inducer with a tip clearance (TC) of τ = 0.32% and with no tip clearance (NTC) is examined with a series of computational fluid dynamics simulations. Removing the TC eliminates tip leakage flow; however, backflow is still observed. In fact, the NTC case showed a 37% increase in the length of the upstream backflow penetration. Tip leakage flow does instigate a smaller secondary leading edge tip vortex that is separate from the much larger backflow structure. A comprehensive analysis of these simulations suggests that blade inlet diffusion, not tip leakage flow, is the fundamental mechanism leading to the formation of backflow.


Author(s):  
W. R. Briley ◽  
D. V. Roscoe ◽  
H. J. Gibeling ◽  
R. C. Buggeln ◽  
J. S. Sabnis ◽  
...  

Three-dimensional solutions of the ensemble-averaged Navier-Stokes equations have been computed for a high-turning turbine rotor passage, both with and without tip clearance effects. The geometry is Pratt & Whitney’s preliminary design for the Generic Gas Generator Turbine (GGGT), having an axial chord of 0.5 inch and turning angle of about 160 degrees. The solutions match the design Reynolds number of 3x 106/inch and design inflow/outflow distributions of flow quantities. The grid contains 627,000 points, including 20 radial points in the clearance gap of 0.015 inch, and has a minimum spacing of 10−4 inch adjacent to all surfaces. The solutions account for relative motion of the blade and shroud surfaces and include a backstep on the shroud. Computed results are presented which show the general flow behavior, especially near the tip clearance and backstep regions. The results are generally consistent with experimental observations for other geometries having thinner blades and smaller turning angles. The leakage flow includes some fluid originally in the freestream at 91 percent span. Downstream, the leakage flow behaves as a wall jet directed at 100 degrees to the main stream, with total pressure and temperature higher than the freestream. Radial distributions of circumferentially-averaged flow quantities are compared for solutions with and without tip leakage flow. Two-dimensional solutions are also presented for the mid-span blade geometry for design and off-design inflow angles.


Sign in / Sign up

Export Citation Format

Share Document