Evolution Process of Diffuser Stall in a Centrifugal Compressor With Vaned Diffuser

Author(s):  
Nobumichi Fujisawa ◽  
Tetsuya Inui ◽  
Yutaka Ohta

The evolution process of a diffuser rotating stall in a centrifugal compressor with a vaned diffuser was investigated by experimental and numerical analyses. From velocity measurements, it was found that the diffuser stall propagated near the shroud side in the vaneless space. As the mass flow decreased, a stage stall rotated within both the impeller and diffuser passages, instead of a diffuser stall. The evolution process of the diffuser stall had three stall forms. First, the diffuser stall, which was rotating on the shroud side, shifted to the hub side. Then, the diffuser stall moved into the impeller passages and evolved to a stage stall. From computational fluid dynamics (CFD) analysis, a tornado-type vortex was generated first, near the hub side of the diffuser leading edge, when the diffuser stall was shifted to the hub side. Next, a throat area blockage was formed near the hub side because of the boundary layer separation in the vaneless space. Finally, the blockage within the diffuser passages expanded to the impeller passages and developed into a stage stall. From the pressure measurements along the impeller and diffuser passages, the magnitude of pressure fluctuation on the casing wall of the diffuser throat area also suddenly increased when the diffuser stall shifted to the hub side. Therefore, the evolution area of the diffuser stall was caused by the evolution of the blockage near the throat area of the diffuser passage.

2019 ◽  
Vol 141 (4) ◽  
Author(s):  
Nobumichi Fujisawa ◽  
Tetsuya Inui ◽  
Yutaka Ohta

This paper describes in detailed flow field in a centrifugal compressor with a vaned diffuser at off design point. Especially, we conducted both the experimental and numerical analysis in order to investigate the evolution process of a diffuser stall. At the stall point, the diffuser stall was initiated and rotated near the shroud side in the vaneless space. Furthermore, the diffuser stall was developed to a stage stall cell, as the mass flow was decreased. The developed stall cell was rotated within both the impeller and diffuser passages. The evolution process of the diffuser stall had three stall forms. First, the diffuser stall was rotating near the shroud side. Then, the diffuser stall shifted to the hub side and moved into the impeller passages. Finally, a stage stall was generated. From computational fluid dynamics (CFD) analysis, a tornado-type vortex was generated first, near the hub side of the diffuser leading edge, when the diffuser stall was shifted to the hub side. Next, a throat area blockage was formed near the hub side because of the boundary layer separation in the vaneless space. Finally, the blockage within the diffuser passages expanded to the impeller passages and developed into a stage stall. From the pressure measurements along the impeller and diffuser passages, the magnitude of pressure fluctuation on the casing wall of the diffuser throat area also suddenly increased when the diffuser stall shifted to the hub side. Therefore, the evolution area of the diffuser stall was caused by the evolution of the blockage near the throat area of the diffuser passage.


2017 ◽  
Vol 2017 ◽  
pp. 1-13 ◽  
Author(s):  
Nobumichi Fujisawa ◽  
Yutaka Ohta

The transition process from a diffuser rotating stall to a stage stall in a centrifugal compressor with a vaned diffuser was investigated by experimental and numerical analyses. From the velocity measurements, it was found that the rotating stall existed on the shroud side of the diffuser passage in the off-design flow condition. The numerical results revealed the typical vortical structure of the diffuser stall. The diffuser stall cell was caused by the systematic vortical structure which consisted of the tornado-type vortex, the longitudinal vortex at the shroud/suction surface corner (i.e., leading edge vortex (LEV)), and the vortex in the throat area of the diffuser passages. Furthermore, the stage stall, which rotated within both the impeller and diffuser passages, occurred instead of the diffuser stall as the mass flow rate was decreased. According to the velocity measurements at the diffuser inlet, the diffuser stall which rotated on the shroud side was shifted to the hub side. Then, the diffuser stall moved into the impeller passages and formed the stage stall. Therefore, the stage stall was caused by the development of the diffuser stall, which transferred from the shroud side to the hub side in the vaneless space and expanded to the impeller passages.


Author(s):  
Nobumichi Fujisawa ◽  
Masaki Takahashi ◽  
Yutaka Ohta

Abstract The transient process of the rotating stall development in a centrifugal compressor with a vaned diffuser was investigated by experimental and numerical analyses. Previous studies show that a diffuser stall triggers a stage stall, which rotates through rotor and stator passages. The vortex evolution at the diffuser throat represents the key factor in diffuser stall development. The developed diffuser stall cell blocked the impeller exit, causing an impeller passage stall. This paper focused on two aspects regarding the transient process of the diffuser stall development. The first aspect is the process by which the vortex at the diffuser throat near the hub side, develops in the circumferential direction. Secondly, we investigated the mechanism of the diffuser stall expansion into impeller passages. The transient analysis of the diffuser stall development was conducted experimentally and numerically by closing the throttle valve abruptly. The hub side blockage was initiated near the cutoff by the strong adverse pressure gradient in the diffuser throat area. Therefore, the key factor in the diffuser stall evolution was the development of a throat blockage near the cutoff, obtained from both experimental and computational fluid dynamics results. Furthermore, the transient stall cell blocked the impeller passages and induced a hub side blockage at the throat of the impeller passages and the impeller leading edge separation. The pressure surface separation of the impeller at the trailing edge had a great impact on the development of the stall cell within impeller passages.


Author(s):  
Nobumichi Fujisawa ◽  
Daiki Ema ◽  
Yutaka Ohta

In this study, the unsteady behavior of a diffuser rotating stall in a centrifugal compressor with a vaned diffuser was investigated through experiments and numerical analyses. From the casing static pressure measurements, it was determined that the diffuser stall propagated at 25% of impeller rotational speed in the vaneless space. The numerical results revealed the presence of a typical vortical structure on the diffuser’s leading edge. Under partial flow condition, a tornado-type vortex was generated on the diffuser’s leading edge. Furthermore, a longitudinal vortex at the shroud/suction surface corner (i.e., leading edge vortex (LEV)) was induced by the rolling-up flow on the diffuser suction surface. As the velocity was decreased, the development of the tornado-type vortex and LEV forms a substantial flow blockage within the diffuser passages. Furthermore, the diffuser stall cell was caused by the systematic vortical structure which consisted of the tornado-type vortex, LEV, and vortex in the throat area of diffuser passages. In addition to this, the developed LEV interacted with the next diffuser leading edge and formed the throat area blockage with the passage of time. Then, the tornado-type vortex and LEV developed by the throat area blockage and diffuser stall cell, which was caused by the systematic vortical structure, propagated to the succeeding diffuser vane. Therefore, the diffuser stall in the centrifugal compressor was caused by the evolution of the tornado-type vortex and LEV.


2012 ◽  
Vol 135 (1) ◽  
Author(s):  
Jonathan N. Everitt ◽  
Zoltán S. Spakovszky

In compression systems, the stable operating range is limited by rotating stall and/or surge. Two distinct types of stall precursors can be observed prior to full scale instability: the development of long-wavelength modal waves or a short-wavelength, three-dimensional flow breakdown (so-called “spike” stall inception). The cause of the latter is not well understood; in axial machines it has been suggested that rotor blade-tip leakage flow plays an important role, but spikes have recently been observed in shrouded vaned diffusers of centrifugal compressors where these leakage flows are not present, suggesting an alternative mechanism may be at play. This paper investigates the onset of instability in a shrouded vaned diffuser from a highly loaded turbocharger centrifugal compressor and discusses the mechanisms thought to be responsible for the development of short-wavelength stall precursors. The approach combines unsteady 3D RANS simulations of an isolated vaned diffuser with previously obtained experimental results. The unsteady flow field simulation begins at the impeller exit radius, where flow is specified by a spanwise profile of flow angle and stagnation properties, derived from single-passage stage calculations but with flow pitchwise mixed. Through comparison with performance data from previous experiments and unsteady full-wheel simulations, it is shown that the diffuser is accurately matched to the impeller and the relevant flow features are well captured. Numerical forced response experiments are carried out to determine the diffuser dynamic behavior and point of instability onset. The unsteady simulations demonstrate the growth of short-wavelength precursors; the flow coefficient at which these occur, the rotation rate and circumferential extent agree with experimental measurements. Although the computational setup and domain limitations do not allow simulation of the fully developed spike nor full-scale instability, the model is sufficient to capture the onset of instability and allows the postulation of the following necessary conditions: (i) flow separation at the diffuser vane leading edge near the shroud endwall; (ii) radially reversed flow allowing vorticity shed from the leading edge to convect back into the vaneless space; and (iii) recirculation and accumulation of low stagnation pressure fluid in the vaneless space, increasing diffuser inlet blockage and leading to instability. Similarity exists with axial machines, where blade-tip leakage sets up endwall flow in the circumferential direction leading to flow breakdown and the inception of rotating stall. Rather than the tip leakage flows, the cause for circumferential endwall flow in the vaned diffuser is the combination of high swirl and the highly nonuniform spanwise flow profile at the impeller exit.


Author(s):  
Nobumichi Fujisawa ◽  
Sota Ikezu ◽  
Yutaka Ohta

The characteristics of a diffuser rotating stall and the evolution of a vortex generated on the diffuser leading edge (i.e., leading-edge vortex (LEV)) in a centrifugal compressor were investigated using experiments and numerical analyses. The experimental results showed that both impeller and diffuser rotating stalls occurred at 55 and 25 Hz during off-design flow operation. Both the stall cells existed only on the shroud side of the flow passages, which is in close proximity to the source location of the LEV. The numerical results showed that the LEV is a combination of a separated vortex near the leading edge and the extended tip-leakage flow from the impeller. In the partial flow operation, the LEV develops as the velocity decreases in the diffuser passages and forms a huge flow blockage within the diffuser passages. Therefore, the LEV may be considered to be one of the causes of diffuser stall in the centrifugal compressor.


Author(s):  
J. N. Everitt ◽  
Z. S. Spakovszky

In compression systems the stable operating range is limited by rotating stall and/or surge. Two distinct types of stall precursors can be observed prior to full scale instability: the development of long-wavelength modal waves or a short-wavelength, three-dimensional flow breakdown (so-called “spike” stall inception). The cause of the latter is not well understood; in axial machines it has been suggested that rotor blade-tip leakage flow plays an important role, but spikes have recently been observed in shrouded vaned diffusers of centrifugal compressors where these leakage flows are not present, suggesting an alternative mechanism may be at play. This paper investigates the onset of instability in a shrouded vaned diffuser from a highly loaded turbocharger centrifugal compressor and discusses the mechanisms thought to be responsible for the development of short-wavelength stall precursors. The approach combines unsteady 3D RANS simulations of an isolated vaned diffuser with previously obtained experimental results. The unsteady flow field simulation begins at the impeller exit radius, where flow is specified by a spanwise profile of flow angle and stagnation properties, derived from single-passage stage calculations but with flow pitchwise mixed. Through comparison with performance data from previous experiments and unsteady full-wheel simulations, it is shown that the diffuser is accurately matched to the impeller and the relevant flow features are well captured. Numerical forced response experiments are carried out to determine the diffuser dynamic behavior and point of instability onset. The unsteady simulations demonstrate the growth of short-wavelength precursors; the flow coefficient at which these occur, the rotation rate and circumferential extent agree with experimental measurements. Although the computational setup and domain limitations do not allow simulation of the fully developed spike nor full-scale instability, the model is sufficient to capture the onset of instability and allows the postulation of the following necessary conditions: (i) flow separation at the diffuser vane leading edge near the shroud endwall; (ii) radially reversed flow allowing vorticity shed from the leading edge to convect back into the vaneless space; and (iii) recirculation and accumulation of low stagnation pressure fluid in the vaneless space, increasing diffuser inlet blockage and leading to instability. Similarity exists with axial machines, where blade-tip leakage sets up endwall flow in the circumferential direction leading to flow breakdown and the inception of rotating stall. Rather than the tip leakage flows, the cause for circumferential endwall flow in the vaned diffuser is the combination of high swirl and the highly non-uniform spanwise flow profile at the impeller exit.


Author(s):  
Yang Zhao ◽  
Jiayi Zhao ◽  
Zhiheng Wang ◽  
Guang Xi

The diffuser rotating stall in a centrifugal compressor with vaned diffuser is one of important unsteady flow phenomena, which limits the operating range of the compressor. In this paper, the unsteady CFD analysis on a low-speed centrifugal compressor has been performed to investigate the flow characteristic in the diffuser and the propagation of the diffuser rotating stall. The flow behaviors at the outlet of the impeller at design and off-design conditions are firstly investigated. It is found that a reversal flow, induced by the tip leakage flow, exists near the shroud at the impeller outlet and becomes serious with the mass flow rate reduced. Due to the span-wise variation of the flow angle at the diffuser inlet and the inversed pressure gradient in the passage, the leading-edge vortex (LEV) generates on the diffuser leading edge. The LEV then induces the secondary flow in the diffuser passage and then causes the hub-corner separation. Furthermore, the propagation of the diffuser rotating stall is presented in details. The suction-side separation near the hub induces the blockage in the passage. And the shedding vortex from the suction side moves toward the leading edge of the adjacent blade. When the vortex reaches to the leading edge of the adjacent blade, the incidence increase and a new separation occurs on the suction side. With the development of the new separation, the passage becomes blocked gradually and the upstream stalled passage recovers to a normal condition. The rotating stall propagates along the direction of the impeller rotation at about 4.5% of the impeller rotational speed.


Author(s):  
Nicolas Buffaz ◽  
Isabelle Trébinjac

The results presented in the paper aim at investigating the impact of tip clearance size and rotation speed on the surge onset in a transonic single-stage centrifugal compressor composed of a backswept splittered unshrouded impeller and a vaned diffuser. For that purpose, various slow throttle ramps into surge were conducted from 100% to 60% design speed of the compressor and two different tip clearance heights were investigated. The 1MW LMFA-ECL test rig was used to carry out the tests in the compressor stage. Unsteady pressure measurements up to 150 KHz were carried out in the inducer (i.e. the entry zone of the impeller between the main blade leading edge and the splitter blade leading edge) and in the diffuser thanks to nine and fifteen static pressure sensors respectively. At cruise rotation speed (92.7% of the nominal rotation speed), the surge is triggered by a boundary layer separation on the diffuser vane suction side whatever the tip clearance height may be. No precursor of surge or pre-surge activity has been recorded in the diffuser or in the impeller. The surge reveals a spike-type inception and the tip clearance increase does not change the path into instability. At lower rotation speeds high frequency disturbances (nearly half the BPF) have been recorded in the inducer before surge. These disturbances can be understood as “tip clearance rotating disturbances” because they are generated at the leading edge of the main blades and move along the tip clearance trajectory. These disturbances reveal a very unstable behavior while the compressor runs into a stable operating point even if the flow at the tip of impeller is dramatically affected by these disturbances. But these disturbances do not trigger the surge which always originates in the diffuser.


2019 ◽  
Vol 142 (1) ◽  
Author(s):  
B. Mischo ◽  
P. Jenny ◽  
Y. Bidaut ◽  
N. Fonzi ◽  
D. Hermann ◽  
...  

Abstract Unshrouded industrial centrifugal compressor impellers operate at high rotational speeds and volume flow rates. Under such conditions, impeller blade excitation is dominated by high frequency interaction with stationary parts, i.e., vaned diffusers or inlet guide vanes. In a previous study conducted on two full compression units of the original equipment manufacturer (OEM), the authors identified, characterized, and quantified resonant blade vibration caused by the interaction of the impeller blades with rotating stall cells during severe off-design conditions. This caused significant dynamic stress in the blades. In a follow-up study, this phenomenon was reproduced successfully experimentally under representative off-design conditions in a downscaled test rig and numerically with unsteady computational fluid dynamics (CFD) and structural mechanical finite element method (FEM) analysis. The gained knowledge was translated into a new diffuser design philosophy, based on sectorwise circumferential variation of the leading edge angle. This paper presents the patented philosophy, which is experimentally verified on the same test rig configuration in terms of flow path geometry and measurement equipment that was used in the mentioned prior study to assess resonant blade interaction. The results confirm the design aims: rotating stall onset was delayed without affecting the aerodynamic performance of the stage. Resonant blade interaction with rotating stall observed in the baseline diffuser could not be avoided with the two new diffuser designs. However, with the two new diffusers, the induced mechanical stresses in the impeller and the excitability were reduced by up to 12%.