Fan Stability With Leading Edge Damage: Blind Prediction and Validation

2021 ◽  
Author(s):  
E. J. Gunn ◽  
T. Brandvik ◽  
M. J. Wilson ◽  
R. Maxwell

Abstract This paper considers the impact of a damaged leading edge on the stall margin and stall inception mechanisms of a transonic, low pressure ratio fan. The damage takes the form of a squared-off leading edge over the upper half of the blade. Full-annulus, unsteady CFD simulations are used to explain the stall inception mechanisms for the fan at low- and high-speed operating points. A combination of steady and unsteady simulations show that the fan is predicted to be sensitive to leading edge damage at low speed, but insensitive at high speed. This blind prediction aligns well with rig test data. The difference in response is shown to be caused by the change between subsonic and supersonic flow regimes at the leading edge. Where the inlet relative flow is subsonic, rotating stall is initiated by growth and propagation of a subsonic leading edge flow separation. This separation is shown to be triggered at higher mass flow rates when the leading edge is damaged, reducing the stable flow range. Where the inlet relative flow is supersonic, the flow undergoes a supersonic expansion around the leading edge, creating a supersonic flow patch terminated by a shock on the suction surface. Rotating stall is triggered by growth of this separation, which is insensitive to leading edge shape. This creates a marked difference in sensitivity to damage at low- and high-speed operating points.

Author(s):  
Fangyuan Lou ◽  
John C. Fabian ◽  
Nicole L. Key

The inception and evolution of rotating stall in a high-speed centrifugal compressor are characterized during speed transients. Experiments were performed in the Single Stage Centrifugal Compressor (SSCC) facility at Purdue University and include speed transients from sub-idle to full speed at different throttle settings while collecting transient performance data. Results show a substantial difference in the compressor transient performance for accelerations versus decelerations. This difference is associated with the heat transfer between the flow and the hardware. The heat transfer from the hardware to the flow during the decelerations locates the compressor operating condition closer to the surge line and results in a significant reduction in surge margin during decelerations. Additionally, data were acquired from fast-response pressure transducers along the impeller shroud, in the vaneless space, and along the diffuser passages. Two different patterns of flow instabilities, including mild surge and short-length-scale rotating stall, are observed during the decelerations. The instability starts with a small pressure perturbation at the impeller leading edge and quickly develops into a single-lobe rotating stall burst. The stall cell propagates in the direction opposite of impeller rotation at approximately one third of the rotor speed. The rotating stall bursts are observed in both the impeller and diffuser, with the largest magnitudes near the diffuser throat. Furthermore, the flow instability develops into a continuous high frequency stall and remains in the fully developed stall condition.


2017 ◽  
Vol 139 (12) ◽  
Author(s):  
Fangyuan Lou ◽  
John C. Fabian ◽  
Nicole L. Key

The inception and evolution of rotating stall in a high-speed centrifugal compressor are characterized during speed transients. Experiments were performed in the single stage centrifugal compressor (SSCC) facility at Purdue University and include speed transients from subidle to full speed at different throttle settings while collecting transient performance data. Results show a substantial difference in the compressor transient performance for accelerations versus decelerations. This difference is associated with the heat transfer between the flow and the hardware. The heat transfer from the hardware to the flow during the decelerations locates the compressor operating condition closer to the surge line and results in a significant reduction in surge margin during decelerations. Additionally, data were acquired from fast-response pressure transducers along the impeller shroud, in the vaneless space, and along the diffuser passages. Two different patterns of flow instabilities, including mild surge and short-length-scale rotating stall, are observed during the decelerations. The instability starts with a small pressure perturbation at the impeller leading edge (LE) and quickly develops into a single-lobe rotating stall burst. The stall cell propagates in the direction opposite of impeller rotation at approximately one-third of the rotor speed. The rotating stall bursts are observed in both the impeller and diffuser, with the largest magnitudes near the diffuser throat. Furthermore, the flow instability develops into a continuous high frequency stall and remains in the fully developed stall condition.


2009 ◽  
Vol 131 (3) ◽  
Author(s):  
Z. S. Spakovszky ◽  
C. H. Roduner

In turbocharger applications, bleed air near the impeller exit is often used for secondary flow systems to seal bearing compartments and to balance the thrust load on the bearings. There is experimental evidence that the performance and operability of highly-loaded centrifugal compressor designs can be sensitive to the amount of bleed air. To investigate the underlying mechanisms and to assess the impact of bleed air on the compressor dynamic behavior, a research program was carried out on a preproduction, 5.0 pressure ratio, high-speed centrifugal compressor stage of advanced design. The investigations showed that bleed air can significantly reduce the stable flow range. Compressor rig experiments, using an array of unsteady pressure sensors and a bleed valve to simulate a typical turbocharger environment, suggest that the path into compression system instability is altered by the bleed flow. Without the bleed flow, the prestall behavior is dominated by short-wavelength disturbances, or so called “spikes,” in the vaneless space between the impeller and the vaned diffuser. Introducing bleed flow at the impeller exit reduces endwall blockage in the vaneless space and destabilizes the highly-loaded vaned diffuser. The impact is a 50% reduction in stable operating range. The altered diffuser characteristic reduces the compression system damping responsible for long-wavelength modal prestall behavior. A four-lobed backward traveling rotating stall wave is experimentally measured in agreement with calculations obtained from a previously developed dynamic compressor model. In addition, a self-contained endwall blockage control strategy was employed, successfully recovering 75% of the loss in surge-margin due to the bleed flow and yielding a one point increase in adiabatic compressor efficiency.


Author(s):  
Z. S. Spakovszky ◽  
C. H. Roduner

In turbocharger applications bleed air near the impeller exit is often used for secondary flow systems to seal bearing compartments and to balance the thrust load on the bearings. There is experimental evidence that the performance and operability of highly loaded centrifugal compressor designs can be sensitive to the amount of bleed air. To investigate the underlying mechanisms and to assess the impact of bleed air on the compressor dynamic behavior, a research program was carried out on a pre-production, 5.0 pressure ratio, high-speed centrifugal compressor stage of advanced design. The investigations showed that bleed air can significantly reduce the stable flow range. Compressor rig experiments, using an array of unsteady pressure sensors and a bleed valve to simulate a typical turbocharger environment, suggest that the path into compression system instability is altered by the bleed flow. Without bleed flow, the pre-stall behavior is dominated by short wavelength disturbances, or so called ‘spikes’, in the vaneless space between the impeller and the vaned diffuser. Introducing bleed flow at impeller exit reduces endwall blockage in the vaneless space and destabilizes the highly-loaded vaned diffuser. The impact is a 50% reduction in stable operating range. The altered diffuser characteristic reduces the compression system damping responsible for long wavelength, modal pre-stall behavior. A four-lobed backward traveling rotating stall wave is experimentally measured, in agreement with calculations obtained from a previously developed dynamic compressor model. In addition, a self-contained, endwall blockage control strategy was employed, successfully recovering 75% of the loss in surge-margin due to bleed flow and yielding a 1 point increase in adiabiatic compressor efficiency.


Author(s):  
Eighdi Aung ◽  
Marco P. Schoen ◽  
Jichao Li

Abstract Axial compressor systems are susceptible to unstable conditions near their optimal operating point. In particular, rotating stall and surge are conditions that need to be avoided during the operation of an axial compressor. In extreme cases these conditions may cause damage to the compressor. The onset of either condition is rather rapid, and usually does not allow for remedial control action based on the limited time available. Hence, research efforts have been focusing on the development of new detection methods that allow for more time to take corrective measures. This paper explores and compares various existing and proposed methods to identify and detect those precursors. The methods detailed in this work are tested at different operating conditions and locations. The methods investigated include the sequentially computed correlation coefficient of pressure sensor data, correlation coefficient, the Generalized Extreme Studentized Deviate Test (ESD) for outlier detection, spectral entropy, and Autoregressive (AR) models. The primary goal of evaluating these methods is based on their suitability for employment as pre-processors for dynamic system identification. By using the dynamics of the identified model rather than a static precursor, it is stipulated that the onset of stall and surge can be managed with a control concept. For this work, the extracted models are investigated for suitability to serve as precursors, and the potential as predictive models. This work may serve for future work to achieve active flow control by direct air injection at the leading edge of the blades. For this work, a one-stage compressor system with a blade geometry that allows for spike inception is utilized. Spike stall inception is a precursor to fully developed rotating stall. The subsonic compressor has 60 blades, and its operating point is controlled by a throttle and constant speed control of the rotor. The pressure data is collected with 10 Kulite™ sensors which are placed along the blade cord length on the outer casing of the compressor. The results of the tabulated performance of the various methods and resulting models indicate that an ARESD combination yields the earliest indication for spike stall inception.


2016 ◽  
Vol 138 (9) ◽  
Author(s):  
Farzad Ashrafi ◽  
Mathias Michaud ◽  
Huu Duc Vo

Rotating stall is a well-known aerodynamic instability in compressors that limits the operating envelope of aircraft gas turbine engines. An innovative method for delaying the most common form of rotating stall inception using an annular dielectric barrier discharge (DBD) plasma actuator had been proposed. A DBD plasma actuator is a simple solid-state device that converts electricity directly into flow acceleration through partial air ionization. However, the proposed concept had only been preliminarily evaluated with numerical simulations on an isolated axial rotor using a relatively basic CFD code. This paper provides both an experimental and a numerical assessment of this concept for an axial compressor stage as well as a centrifugal compressor stage, with both stages being part of a low-speed two-stage axial-centrifugal compressor test rig. The two configurations studied are the two-stage configuration with a 100 mN/m annular casing plasma actuator placed just upstream of the axial rotor leading edge (LE) and the single-stage centrifugal compressor with the same actuator placed upstream of the impeller LE. The tested configurations were simulated with a commercial RANS CFD code (ansys cfx) in which was implemented the latest engineering DBD plasma model and dynamic throttle boundary condition, using single-passage multiple blade row computational domains. The computational fluid dynamics (CFD) simulations indicate that in both types of compressors, the actuator delays the stall inception by pushing the incoming/tip clearance flow interface downstream into the blade passage. In each case, the predicted reduction in stalling mass flow matches the experimental value reasonably well.


Author(s):  
Michael Braun ◽  
Joerg R. Seume

The present paper provides a comparison of a CDA-bladed four-stage high-speed axial compressor and a configuration in which the first three rows are replaced with forward swept blades and vanes. The blades are designed with sweep from mid-span to tip, the vanes from mid-span to the hub. The non-swept portion of the leading edge is kept radial and identical to the CDA blading. The overall performance of the compressor with both configurations is measured at five engine speeds. The flow fields of each rotor and stator at two operating points (“Design Point” and “Near Stall”) of both configurations are investigated at the design speed. On the suction and the pressure side of the third stage vane, static surface pressures are measured to determine the local Mach number distribution and to identify zones of separation. Multistage CFD-computations are carried out for both configurations. The numerical and experimental results of both configurations are compared and show the effect of sweep on the operating map of the compressor from choke to stall: Sweep reduces corner stall and the end-wall losses at high aerodynamic loads. It is shown that the reduction of separation due to sweep leads to an increase of total pressure rise towards lower mass flow so that the present swept compressor achieves higher total pressure ratios at and near the stall limit. An analysis along streamlines suggests that the performance of the compressor could have been improved further by a more uniform total pressure distribution in the front stages and a better match of the sweep in stages 2 and 3.


2015 ◽  
Vol 137 (5) ◽  
Author(s):  
J. Dodds ◽  
M. Vahdati

In this two-part paper the phenomenon of part span rotating stall is studied. The objective is to improve understanding of the physics by which stable and persistent rotating stall occurs within high speed axial flow compressors. This phenomenon is studied both experimentally (Part I) and numerically (Part II). The experimental observations reported in Part I are now explored through the use of 3D unsteady Reynolds-averaged Navier–Stokes (RANS) simulation. The objective is to both validate the computational model and, where possible, explore some physical aspects of the phenomena. Unsteady simulations are presented, performed at a fixed speed with the three rows of variable stator vanes adjusted to deliberately mismatch the front stages and provoke stall. Two families of rotating stall are identified by the model, consistent with experimental observations from Part I. The first family of rotating stall originates from hub corner separations developing on the stage 1 stator vanes. These gradually coalesce into a multicell rotating stall pattern confined to the hub region of the stator and its downstream rotor. The second family originates from regions of blockage associated with tip clearance flow over the stage 1 rotor blade. These also coalesce into a multicell rotating stall pattern of shorter length scale confined to the leading edge tip region. Some features of each of these two patterns are then explored as the variable stator vanes (VSVs) are mismatched further, pushing each region deeper into stall. The numerical predictions show a credible match with the experimental findings of Part I. This suggests that a RANS modeling approach is sufficient to capture some important aspects of part span rotating stall behavior.


Author(s):  
S. E. Gorrell ◽  
P. M. Russler

The stall inception process in high-speed compressor components is important to understand in order to increase stage loading while maintaining stall margin. This paper presents the results of an in depth experimental investigation on the stall inception of a two stage, high-speed, low aspect ratio fan that is representative of current operational commercial and military fan technology. High-response static pressure measurements are presented which detail the stall inception process of the fan under various operating conditions. These conditions include: varied corrected speeds, a smooth case, a circumferential groove casing treatment, and a recirculating cavity casing treatment. Stage pressure characteristics and radial pressure ratio profiles are presented for the different operating conditions. The stage performance data, together with the static pressure data, are analyzed to provide a clear and thorough understanding of the stall inception process and how the process may vary under different conditions. Experimental results show that a stage may stall on the positive, neutral, or negative sloped part of the pressure characteristic. The three casing treatments had a significant effect on the rotor tip flow and these variations changed the stall inception path of the fan. Stall inception was characterized by the formation of a stall inception cell which grew to fully developed rotating stall. Properties affected by the changing tip flow include the stall inception duration, stall inception cell frequency, existence of modal waves, duration of modal waves, and modal wave frequency. In some instances modal waves appear to play a role in stall inception, in others they do not.


1991 ◽  
Vol 113 (2) ◽  
pp. 290-301 ◽  
Author(s):  
V. H. Garnier ◽  
A. H. Epstein ◽  
E. M. Greitzer

Stall inception has been studied in two low-speed compressors (a single-stage and a three-stage) and in a high-speed three-stage compressor, using temporally and spatially resolved measurements. In all three machines, rotating stall was preceded by a period in which small-amplitude waves were observed traveling around the circumference of the machine at a speed slightly less than the fully developed rotating stall cell speed. The waves evolved smoothly into rotating stall without sharp changes in phase or amplitude, implying that, in the machines tested, the prestall waves and the fully developed rotating stall are two stages of the same phenomenon. The growth rate of these disturbances was in accord with that predicted by current analytical models. The prestall waves were observed both with uniform and with distorted inflow, but were most readily discerned with uniform inflow. Engineering uses and limitations of these waves are discussed.