scholarly journals Development and Validation of a Finite Element Model of the Pelvis

Author(s):  
Andrew E. Anderson ◽  
Christopher L. Peters ◽  
Benjamin D. Tuttle ◽  
Jeffrey A. Weiss

An improved understanding of the stress distribution in and around the hip joint may provide important information regarding the relationship between altered pelvic and acetabular geometry and development of hip osteoarthritis, as well as point to improved diagnostic methods and analysis of surgical treatment. It is very difficult to accurately assess how changes in pelvic geometry affect the stress and strain distribution of the joint in an experimental setting. The finite element (FE) method provides an alternative approach for study of hip joint mechanics. Although FE models of the pelvis have been developed, validation by direct comparison with subject-specific experimental measurements has not been performed. In addition, previous models have utilized over-simplified bone geometry and homogeneous material properties. The objectives of this study were to 1) develop and validate a FE model of the pelvis using subject-specific measurements of bone geometry as well as location-dependent cortical thickness and trabecular bone elastic modulus, and 2) assess the sensitivity of the subject-specific FE model to changes in material properties and cortical thickness.

2019 ◽  
Vol 48 (4) ◽  
pp. 1181-1195 ◽  
Author(s):  
Yuyang Wei ◽  
Zhenmin Zou ◽  
Guowu Wei ◽  
Lei Ren ◽  
Zhihui Qian

AbstractThis paper aims to develop and validate a subject-specific framework for modelling the human hand. This was achieved by combining medical image-based finite element modelling, individualized muscle force and kinematic measurements. Firstly, a subject-specific human hand finite element (FE) model was developed. The geometries of the phalanges, carpal bones, wrist bones, ligaments, tendons, subcutaneous tissue and skin were all included. The material properties were derived from in-vivo and in-vitro experiment results available in the literature. The boundary and loading conditions were defined based on the kinematic data and muscle forces of a specific subject captured from the in-vivo grasping tests. The predicted contact pressure and contact area were in good agreement with the in-vivo test results of the same subject, with the relative errors for the contact pressures all being below 20%. Finally, sensitivity analysis was performed to investigate the effects of important modelling parameters on the predictions. The results showed that contact pressure and area were sensitive to the material properties and muscle forces. This FE human hand model can be used to make a detailed and quantitative evaluation into biomechanical and neurophysiological aspects of human hand contact during daily perception and manipulation. The findings can be applied to the design of the bionic hands or neuro-prosthetics in the future.


2005 ◽  
Vol 127 (3) ◽  
pp. 364-373 ◽  
Author(s):  
Andrew E. Anderson ◽  
Christopher L. Peters ◽  
Benjamin D. Tuttle ◽  
Jeffrey A. Weiss

A better understanding of the three-dimensional mechanics of the pelvis, at the patient-specific level, may lead to improved treatment modalities. Although finite element (FE) models of the pelvis have been developed, validation by direct comparison with subject-specific strains has not been performed, and previous models used simplifying assumptions regarding geometry and material properties. The objectives of this study were to develop and validate a realistic FE model of the pelvis using subject-specific estimates of bone geometry, location-dependent cortical thickness and trabecular bone elastic modulus, and to assess the sensitivity of FE strain predictions to assumptions regarding cortical bone thickness as well as bone and cartilage material properties. A FE model of a cadaveric pelvis was created using subject-specific computed tomography image data. Acetabular loading was applied to the same pelvis using a prosthetic femoral stem in a fashion that could be easily duplicated in the computational model. Cortical bone strains were monitored with rosette strain gauges in ten locations on the left hemipelvis. FE strain predictions were compared directly with experimental results for validation. Overall, baseline FE predictions were strongly correlated with experimental results (r2=0.824), with a best-fit line that was not statistically different than the line y=x(experimental strains=FEpredicted strains). Changes to cortical bone thickness and elastic modulus had the largest effect on cortical bone strains. The FE model was less sensitive to changes in all other parameters. The methods developed and validated in this study will be useful for creating and analyzing patient-specific FE models to better understand the biomechanics of the pelvis.


Author(s):  
Jami M. Saffioti ◽  
Brittany Coats

Current finite element (FE) models of the pediatric eye are based on adult material properties [2,3]. To date, there are no data characterizing the age dependent material properties of ocular tissues. The sclera is a major load bearing tissue and an essential component to most computational models of the eye. In preparation for the development of a pediatric FE model, age-dependent and anisotropic properties of sclera were evaluated in newborn (3–5 days) and toddler (4 weeks) pigs. Data from this study will guide future testing protocols for human pediatric specimens.


2017 ◽  
Vol 53 ◽  
pp. 162-167 ◽  
Author(s):  
Maria Constantinou ◽  
Aderson Loureiro ◽  
Christopher Carty ◽  
Peter Mills ◽  
Rod Barrett

2011 ◽  
Vol 223 ◽  
pp. 733-742 ◽  
Author(s):  
Barbara Linke ◽  
Michael Duscha ◽  
Anh Tuan Vu ◽  
Fritz Klocke

The grinding process is one of the most important finishing processes to obtain high surface quality. Nowadays, grinding is also considered as a high performance process with high material removal rates. Nevertheless, to avoid thermally-induced structural changes poses a major challenge for this manufacturing technology. Until now, the Finite Element Method (FEM) has been widely applied as a proper numerical technique to predict workpiece properties in machining processes. However, actual models in grinding are limited to conventional grinding processes with simple workpiece profiles and low table speeds. In this paper, finite element simulations are expanded to 3-dimensional (3D) models with temperature-dependent material properties and heat source profiles derived from experimental results, i.e. tangential forces. Both temperature simulation and measurement were conducted for deep grinding, pendulum grinding and speed stroke grinding in the table speed range of vw= 12 m/min to 180 m/min and specific material removal rates of Q’w= 40 mm³/mms. Overall, the simulation results show a good agreement with the measured temperature and surface integrity after grinding. This research indicates that a 3D FE model with temperature dependent material properties can predict realistic temperature fields in speed stroke grinding. Therefore, the experiment and measurement costs and time can be reduced by FEM simulation.


2019 ◽  
Vol 16 (03) ◽  
pp. 1842012 ◽  
Author(s):  
Zimo Zhu ◽  
Donna C. Jones ◽  
G. R. Liu ◽  
Sajjad Soleimani ◽  
Xu Huang ◽  
...  

Finite element (FE) analysis has been widely used to investigate bone responses to mechanical loading. Research in long bones has been straight forward because modeling of these bones requires only two material properties. Such an FE model may provide an adequate approximation of the anatomy for many cases. However, a more detailed model of skull bones is needed to accurately capture its complex structure of multiple bone pieces and the various mineral densities distributed throughout these bone pieces. Unfortunately, FE model development incorporating both complex geometries and anatomically accurate material properties is both computationally and labor intensive. In this study, a method is proposed to automatically segment micro-computed tomography ([Formula: see text]-CT) scan images of bone pieces to build an FE model of a full swine hemi-skull. Using the Digital Imaging and Communications in Medicine (DICOM) files from scanned bones, the complete geometry of each bone piece is recreated through seven customized processing algorithms. After assembling the bone pieces to form the skull, experimentally derived Young’s modulus values are correlated to grayscale values to produce a detailed FE model for accurate simulation. This detailed skull model can be used to predict strain/stress patterns in response to various loading regimes to facilitate research questions in fracture healing and growth, as well as bone tissue engineering and bone mineral density loss (e.g., osteoporosis).


2006 ◽  
Vol 129 (1) ◽  
pp. 12-19 ◽  
Author(s):  
M. Papini ◽  
R. Zdero ◽  
E. H. Schemitsch ◽  
P. Zalzal

To assess the performance of femoral orthopedic implants, they are often attached to cadaveric femurs, and biomechanical testing is performed. To identify areas of high stress, stress shielding, and to facilitate implant redesign, these tests are often accompanied by finite element (FE) models of the bone/implant system. However, cadaveric bone suffers from wide specimen to specimen variability both in terms of bone geometry and mechanical properties, making it virtually impossible for experimental results to be reproduced. An alternative approach is to utilize synthetic femurs of standardized geometry, having material behavior approximating that of human bone, but with very small specimen to specimen variability. This approach allows for repeatable experimental results and a standard geometry for use in accompanying FE models. While the synthetic bones appear to be of appropriate geometry to simulate bone mechanical behavior, it has not, however, been established what bone quality they most resemble, i.e., osteoporotic or osteopenic versus healthy bone. Furthermore, it is also of interest to determine whether FE models of synthetic bones, with appropriate adjustments in input material properties or geometric size, could be used to simulate the mechanical behavior of a wider range of bone quality and size. To shed light on these questions, the axial and torsional stiffness of cadaveric femurs were compared to those measured on synthetic femurs. A FE model, previously validated by the authors to represent the geometry of a synthetic femur, was then used with a range of input material properties and change in geometric size, to establish whether cadaveric results could be simulated. Axial and torsional stiffnesses and rigidities were measured for 25 human cadaveric femurs (simulating poor bone stock) and three synthetic “third generation composite” femurs (3GCF) (simulating normal healthy bone stock) in the midstance orientation. The measured results were compared, under identical loading conditions, to those predicted by a previously validated three-dimensional finite element model of the 3GCF at a variety of Young’s modulus values. A smaller FE model of the 3GCF was also created to examine the effects of a simple change in bone size. The 3GCF was found to be significantly stiffer (2.3 times in torsional loading, 1.7 times in axial loading) than the presently utilized cadaveric samples. Nevertheless, the FE model was able to successfully simulate both the behavior of the 3GCF, and a wide range of cadaveric bone data scatter by an appropriate adjustment of Young’s modulus or geometric size. The synthetic femur had a significantly higher stiffness than the cadaveric bone samples. The finite element model provided a good estimate of upper and lower bounds for the axial and torsional stiffness of human femurs because it was effective at reproducing the geometric properties of a femur. Cadaveric bone experiments can be used to calibrate FE models’ input material properties so that bones of varying quality can be simulated.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Mohammad Gharaibeh

Purpose This study aims to discuss the determination of the unknown in-plane mechanical material properties of printed circuit boards (PCBs) by correlating the results from dynamic testing and finite element (FE) models using the response surface method (RSM). Design/methodology/approach The first 10 resonant frequencies and vibratory mode shapes are measured using modal analysis with hammer testing experiment, and hence, systematically compared with finite element analysis (FEA) results. The RSM is consequently used to minimize the cumulative error between dynamic testing and FEA results by continuously modifying the FE model, to acquire material properties of PCBs. Findings Great agreement is shown when comparing FEA to measurements, the optimum in-plane material properties were identified, and hence, verified. Originality/value This paper used FEA and RSMs along with modal measurements to obtain in-plane material properties of PCBs. The methodology presented here can be easily generalized and repeated for different board designs and configurations.


Author(s):  
Emiliano P Ravera ◽  
Marcos J Crespo ◽  
Paola A Catalfamo Formento

Analysis of the human locomotor system using rigid-body musculoskeletal models has increased in the biomechanical community with the objective of studying muscle activations of different movements. Simultaneously, the finite element method has emerged as a complementary approach for analyzing the mechanical behavior of tissues. This study presents an integrative biomechanical framework for gait analysis by linking a musculoskeletal model and a subject-specific finite element model of the pelvis. To investigate its performance, a convergence study was performed and its sensitivity to the use of non-subject-specific material properties was studied. The total hip joint force estimated by the rigid musculoskeletal model and by the finite element model showed good agreement, suggesting that the integrative approach estimates adequately (in shape and magnitude) the hip total contact force. Previous studies found movements of up to 1.4 mm in the anterior–posterior direction, for single leg stance. These results are comparable with the displacement values found in this study: 0–0.5 mm in the sagittal axis. Maximum von Mises stress values of approximately 17 MPa were found in the pelvic bone. Comparing this results with a previous study of our group, the new findings show that the introduction of muscular boundary conditions and the flexion–extension movement of the hip reduce the regions of high stress and distributes more uniformly the stress across the pelvic bone. Thus, it is thought that muscle force has a relevant impact in reducing stresses in pelvic bone during walking of the finite element model proposed in this study. Future work will focus on including other deformable structures, such as the femur and the tibia, and subject-specific material properties.


Sign in / Sign up

Export Citation Format

Share Document