Fluid Flow and Heat Transfer Induced by a Window Air Conditioner Unit and Associated Thermal Comfort

Author(s):  
Hamza Begdouri ◽  
Luis Rosario ◽  
Muhammad M. Rahman

This study considers airflow simulations to evaluate the impact of different window air-conditioner locations on the thermal comfort in an office rooms (OR). This paper compares the air distribution for an office room by using computational fluid dynamics (CFD) modeling. The air distribution was modeled for a typical office room window air conditioning unit, air supply from a high pressure on the top and the low pressure exhaust on the bottom considering the existing manufacturing ratios for surface areas. Calculations were done for steady-state conditions including an occupant and a light source. The discharge angle for the supply grill of the AC unit was varied from 20 to 40 degrees. The position of the air conditioner was also varied and studied at 60%, 75% and 90% of the total height of the room. In addition the location of the occupant within the office room was varied. Predictions of the air movement, room temperature, room relative humidity, comfort level, and distribution of contaminants within the office room are shown. Analysis of these simulations is discussed. The positions of the air-conditioner unit, the inlet angle and the occupant position in the office room have shown to have important impacts on air quality and thermal comfort. Results are in good agreement with available experimental data.

Solar Energy ◽  
2006 ◽  
Author(s):  
Kybum Jeong ◽  
Moncef Krarti ◽  
Zhiqiang Zhai

The partition air distribution systems evaluated in this study allow occupants to control the system mode (on/off) and the supply air velocity and direction with similar flexibility as occupants in automobiles. To find optimal specifications for the partition air distribution systems that are able to achieve comfortable micro-environment, a CFD modeling tool was used to simulate the airflow and thermal performance of the partition air distribution systems in a typical office space. By analyzing the distribution characteristics of indoor air temperature, air velocity and thermal comfort index, the study assessed the performance of the partition air distribution systems with different operating parameters. The simulation results were analyzed and evaluated to assess both occupant’s thermal comfort and system energy consumption. The study shows that space cooling energy can be reduced while maintaining acceptable indoor thermal comfort level using a partition air distribution system with a higher supply air temperature.


2016 ◽  
Vol 26 (10) ◽  
pp. 1382-1396 ◽  
Author(s):  
Eusébio Z. E. Conceição ◽  
Cristina I. M. Santiago ◽  
Hazim B. Awbi

This paper presents a comparative numerical study of different ceiling-mounted-localized air distribution systems placed above students in a virtual classroom in summer conditions. The influence of four different ceiling-mounted-localized air distribution systems, using vertical descendent jets, on the thermal comfort, local thermal discomfort, and air quality levels was numerically evaluated. The air distribution index, developed previously, was used for non-uniform environment. This index considers the thermal comfort level, air quality level, effectiveness for heat removal, and effectiveness for contaminant removal. Numerical simulations were conducted for a virtual classroom equipped with one of four different ceiling-mounted-localized air distribution systems and with 6 desks, 6 or 12 students, and 2 upper airflow outlets. Inlet air supply temperature of 20 and 24℃ and an outdoor air temperature of 28℃ were used. The simulation results show that the air supply system having a vertical air jet placed at 1.8 m above the floor level (Case III), and with an inlet area of 0.01 m2 and a supply air velocity of 3 m/s would represent the best option in comparison with other air supply methods. In general, the air distribution index value decreases with an increase in inlet air temperature and the number of occupants. The air distribution index values are highest for Case III representing a classroom with 6 or 12 occupants with an inlet air temperature of 20 or 24℃.


Energies ◽  
2021 ◽  
Vol 14 (23) ◽  
pp. 8130
Author(s):  
Ziwen Dong ◽  
Liting Zhang ◽  
Yongwen Yang ◽  
Qifen Li ◽  
Hao Huang

Stratified air distribution systems are commonly used in large space buildings. The research on the airflow organization of stratified air conditioners is deficient in terms of the analysis of multivariable factors. Moreover, studies on the coupled operation of stratified air conditioners and natural ventilation are few. In this paper, taking a Shanghai Airport Terminal departure hall for the study, air distribution and thermal comfort of the cross-section at a height of 1.6 m are simulated and compared under different working conditions, and the effect of natural ventilation coupling operation is studied. The results show that the air distribution is the most uniform and the thermal comfort is the best (predicted mean vote is 0.428, predicted percentage of dissatisfaction is 15.2%) when the working conditions are 5.9% air supply speed, 11 °C cooling temperature difference and 0° air supply angle. With the coupled operation of natural ventilation, the thermal comfort can be improved from Grade II to Grade I.


Author(s):  
Kaleb Pattawi ◽  
Prateek Munankarmi ◽  
Michael Blonsky ◽  
Jeff Maguire ◽  
Sivasathya Pradha Balamurugan ◽  
...  

Abstract Residential buildings, accounting for 37% of the total electricity consumption in the United States, are suitable for demand response (DR) programs to support effective and economical operation of the power system. A home energy management system (HEMS) enables residential buildings to participate in such programs, but it is also important for HEMS to account for occupant preferences to ensure occupant satisfaction. For example, people who prefer a higher thermal comfort level are likely to consume more energy. In this study, we used foresee™, a HEMS developed by the National Renewable Energy Lab (NREL), to perform a sensitivity analysis of occupant preferences with the following objectives: minimize utility cost, minimize carbon footprint, and maximize thermal comfort. To incorporate the preferences into the HEMS, the SMARTER method was used to derive a set of weighting factors for each objective. We performed week-long building energy simulations using a model of a home in Fort Collins, Colorado, where there is mandatory time-of-use electricity rate structure. The foresee™ HEMS was used to control the home with six different sets of occupant preferences. The study shows that occupant preferences can have a significant impact on energy consumption and is important to consider when modeling residential buildings. Results show that the HEMS could achieve energy reduction ranging from 3% to 21%, cost savings ranging from 5% to 24%, and carbon emission reduction ranging from 3% to 21%, while also maintaining a low thermal discomfort level ranging from 0.78 K-hour to 6.47 K-hour in a one-week period during winter. These outcomes quantify the impact of varying occupant preferences and will be useful in controlling the electrical grid and developing HEMS solutions.


2019 ◽  
Vol 11 (15) ◽  
pp. 4166 ◽  
Author(s):  
Liu ◽  
Zhu ◽  
Kim ◽  
Srebric

Computational fluid dynamics (CFD) is an effective analysis method of personalized ventilation (PV) in indoor built environments. As an increasingly important supplement to experimental and theoretical methods, the quality of CFD simulations must be maintained through an adequately controlled numerical modeling process. CFD numerical data can explain PV performance in terms of inhaled air quality, occupants’ thermal comfort, and building energy savings. Therefore, this paper presents state-of-the-art CFD analyses of PV systems in indoor built environments. The results emphasize the importance of accurate thermal boundary conditions for computational thermal manikins (CTMs) to properly analyze the heat exchange between human body and the microenvironment, including both convective and radiative heat exchange. CFD modeling performance is examined in terms of effectiveness of computational grids, convergence criteria, and validation methods. Additionally, indices of PV performance are suggested as system-performance evaluation criteria. A specific utilization of realistic PV air supply diffuser configurations remains a challenging task for further study. Overall, the adaptable airflow characteristics of a PV air supply provide an opportunity to achieve better thermal comfort with lower energy use based on CFD numerical analyses.


2019 ◽  
Vol 29 (2) ◽  
pp. 240-254 ◽  
Author(s):  
Yunqing Fan

The impact of air supply control strategies (louvers movement) on indoor thermal environment were evaluated in this study. The temperature uniformity was evaluated by: (i) the air distribution performance index (ADPI) to determine the air diffusion performance in heating mode; (ii) the air draught rate (DR%) on the face to determine the local discomfort due to cold draught; (iii) the mathematically determined vertical temperature stratification in a room with Beta distributions. A comparison of the conventional type with three different oscillating type airflows (louvers swing angle ±20°, ±40° and ±60°) were experimentally analysed to determine appropriate air supply control strategies. The results indicated that Beta distributions could capture the overall trend of the oscillating airflow, to establish the acceptable thermal uniformity and higher thermal effectiveness. The oscillating airflow as generated by the side-to-side swing type delivery louvers mounted inside a cassette split type air conditioner could shorten heating time by 20% to attain room temperature from 9°C. The data reveal that oscillating airflow can provide a better thermal sensation to feeling warm in the heating mode at both ankle and neck level. The ADPI is approximately 85% in the occupied zone. The actual draught rates on the face ranged 0–35%.


2020 ◽  
Vol 12 (22) ◽  
pp. 9672
Author(s):  
Mamdooh Alwetaishi ◽  
Ashraf Balabel ◽  
Ahmed Abdelhafiz ◽  
Usama Issa ◽  
Ibrahim Sharaky ◽  
...  

The study investigated the level of thermal comfort in historical buildings located at a relatively high altitude in the Arabian Desert of Saudi Arabia. The study focused on the impact of the use of thermal mass and orientation on the level of thermal performance at Shubra and Boqri Palaces. Qualitative and quantitative analyses were used in this study, including a questionnaire interview with architecture experts living at the relatively high altitude of Taif city, to obtain data and information from local experts. The computer software TAS EDSL was used along with on-site equipment, such as thermal imaging cameras and data loggers, to observe the physical conditions of the building in terms of its thermal performance. The study revealed that the experts’ age and years of experience were important aspects while collecting data from them during the survey. The use of thermal mass had a slight impact on the indoor air temperature as well as the energy consumption, but it helped in providing thermal comfort. Use of ventilation can improve thermal comfort level. Evaporative cooling technique has a considerable impact on reducing indoor air temperature with 4 °C drop, improving the thermal comfort sensation level. The novelty of this work is that, it links the outcomes of qualitative results of experts with field monitoring as well as computer modelling. This can contribute as method to accurately collect data in similar case studies.


Nano LIFE ◽  
2018 ◽  
Vol 08 (02) ◽  
pp. 1840006
Author(s):  
Jing Li ◽  
Mengnan Qi ◽  
Qiuhua Duan ◽  
Lei Huo ◽  
Julian Wang

Significant changes in the urban built environment have occurred due to rapid urbanization and increases in the urban population. Such alterations may produce environmental health-related issues such as urban heat stress, air pollution and traffic noise. This research undertook a field study to collect data including urban design parameters, micro-environmental factors and city climatic information. This work was conducted over a two-year period on three pedestrian streets located in high-density urban areas in Beijing. These areas were selected in order to study the influences of urban street canyon texture within a particular geometric layout, wind flow corridors and variations in air temperature on pedestrian microclimatic comfort. The results will facilitate the work of urban planners by providing them with information for use in improving outdoor thermal comfort through their designs. A total of 60[Formula: see text]485 samples were organized into training, validation and test sets. We confirmed our hypothesis that internal wind speed ([Formula: see text] is attributable mainly to the urban texture coefficient ([Formula: see text], air temperature ([Formula: see text] and leading-in wind speed ([Formula: see text]. The model was tested using the test data collected onsite, which demonstrated a very accurate goodness-of-fit; the model achieved an R-squared value of 0.82, which meant that [Formula: see text] as a dependent variable was 82% correlated to the three predictors as independent variables. With this computer simulation, urban planners can now predict and visualize the impact of changes on the built environment in terms of either the direction of solar radiation received or increases in wind speed, in return for the desired thermal comfort level for residents of the neighborhood.


2014 ◽  
Vol 1008-1009 ◽  
pp. 1088-1091
Author(s):  
Lan Xia Guo ◽  
Xiao Yong Peng ◽  
Jian Xiang Liu ◽  
Xu Sheng Chai ◽  
Jing Jing Liang ◽  
...  

Airpak was applied to numerically simulate the air distribution under the same air supply temperature ,different air supply velocity (3.6m/s、2.7m/s and 1.8m/s ) and air supply angle (+15°、-45° and-75°) , and evaluate thermal comfort by Comparative analysis velocity fields, temperature fields, PMV—PPD. The results show that different air supply velocity and air supply angle have a significant impact on indoor air distribution under the same air supply temperature. Air supply angle Plays a vital role in pattern and distribution of indoor flow field,air supply velocity mainly effect the magnitude of indoor velocity and temperature. Synthetically comparied, the model’s best supply parameters are supply velocity 2.7m/s and supply angle75°,which mean value of indoor PMV is-0.09, PPD is 8.5%.


Sign in / Sign up

Export Citation Format

Share Document